SDR HNAA2013020800038Bulb · inoperativeCEILING EMERGENCY LIGHT IS INOPERATIVE AT ROW 7. R & R BULB, AT SAID LOCATION. OPS CHECKED GOOD.SDR HNAA2013020800037Bulb · failedEMERGENCY CEILING LIGHT IS INOPERATIVE AT ROW 3. R & R BULB. OPS CHECKED GOOD.SDR HNAA2013020800036Lead · burnedEMERGENCY LIGHTS FLICKERED ON IN CRUISE FLIGHT WITH PROP HEAT ON. INSPECTED WIRING AND CHECKED RESISTANCE FOR NR 1 AND NR 2 BRUSH BLOCKS AND SLIP RINGS. CHECKED GOOD. INSTALLED PANELS. FOUND HEATER LEAD CRACKED ON NR 200 NR 3 BLADE. R & R HEATER LEAD IAW MMSDR HNAA2013020800035Sensor · out of adjustLT FWD GEAR DOOR REMAINED OPEN, AFTER GEAR RETRACTION AND ADVISORY LIGHT REMAINED ILLUMINATED, UNTIL GEAR SELECTED DOWN. ADJUSTED SENSOR GAP. R & R ACTUATOR HOOK LINK AND HARDWARE. R & R BUSHINGS AND HARDWARE AT DOOR CONNECTING ROD TO LEVER. SWUNG GEAR SEVESDR CA130208005Case · fractured(CAN) DURING CRUISE, FLIGHT CREW NOTICED THAT THE HYD NR 2 SYS OIL LEVEL WAS SLOWLY DROPPING. UPON ARRIVAL, MAINTENANCE FOUND THE RT OTBD ROLL SPOILER ACTUATOR CASING FRACTURED. THE ACTUATOR WAS REPLACED, TESTED AND THE ACFT RELEASED FOR SERVICE.SDR CA130212024Light · corroded(CAN) F/A NOTICED SMOKE COMING FROM AIRSTAIR DOOR, UNABLE TO FIND CONCLUSIVE CAUSE OF THE ARCING IN THE AIR STAIR. FOUND THE WATER DAMAGE ON ALL 4 LED LIGHT ASSY, PN 2LA285028-01. REPLACED WITH PRE-EO DH8-5210-A08052, AIR STAIR LIGHT ASSY, PN 10-1180-1) DUSDR CA130207002Control Rod · bent(CAN) DURING A SCHEDULED MAINTENANCE TASK, MAINTENANCE PERSONNEL DISCOVERED THAT THE PILOT`S BRAKE PEDAL CONTROL ROD WAS BENT. IPC REF 27-20-00, FIG 10, ITEM 190. THE CONTROL ROD IS TO BE REPLACED IAW THE AMM.SDR CA130206006Actuator · cracked(CAN) NR 1 HYD SYS QTY DROPPED AT THRESHOLD. ISO LIGHT CAME ON AND LOSS STABLED. RESOLVED ON W/O: 371368, TASKCARD: NR-00001. RT INBRD SPOILER ACTUATOR REPLACED IAW MM 27-00-00, GROUND RUN LEAK CHECKED SERVICEABLE.SDR HNAA2013020400033Bulb · failedEMERGENCY FLOOR PATH LIGHT, 4TH FROM FORWARD POSITION IS INOPERATIVE. R & R BULB FOR EMERGENCY PATH FLOOR LIGHT. OPS CHECKED GOOD.SDR HNAA2013020400032Bulb · failedAFTER F/A'S PA ANNOUNCEMENT DURING TAXI OUT, EMERGENCY SWITCH BACK LIGHT AND PA SWITCH BACK LIGHT WERE FOUND TO BE INOP WITH ELECTRICAL SMELL FROM PANEL AREA. ALL SWITCH FUNCTION NORMAL. RELAMP BACK LIGHT BULBS AND INSPECTED F/A'S CONTROL PANEL. NO SIGNS OF SDR HNAA2013020400031Connector · saturatedDURING CRUISE FLIGHT AT 12K, SELECTED PROP HEAT ON AND RT AC BUSS FAULT OCCURED. INSPECTED BOTH PROP BRUSH BLOCKS, FOUND NR 2 PROP BRUSH BLOCK CONNECTOR PLUG SOAKED WITH DEICE FLUID. CLEANED AND DRIED CONNECTOR PLUG AS REQUIRED. GROUND RAN BOTH ENGINES WITH SDR CA130204002Window · failed(CAN) DURING A RAMP VISIT, MAINTENANCE PERSONNEL WERE DRIVING BY THE ACFT AND HAD NOTICED THAT THE CAPTAIN`S SIDE WINDOW WAS SHATTERED. IT WAS UNKNOWN WHEN THIS HAD OCCURRED. THE ACFT WAS REMOVED FROM THE GATE AND BROUGHT TO THE HANGAR WHERE THE SIDE WINDOW SDR HNAA2013020100030Light · out of positionEMERGENCY FLOOR LIGHT MODULE IS OFF POSITION AT ROW 9. POSITIONED EMERGENCY FLOOR LIGHT MODULE AT ROW 9.SDR HNAA2013013000029Bulb · failedEMERGENCY EXIT SIGN OVER AIRSTAIR DOOR HAS BULB INOPERATIVE. REMOVED LENS, REMOVED AND REPLACED BULBS. REINSTALLED LENS. OPS CHECKED GOOD.SDR HNAA2013013000028Line · leakingIN FLIGHT, NR 1 SYS LOST HYD PRESSURE. 1/2 QT REMAINED. PRESSURE AT 3000. NR 1 HYD ISOLATION VALVE AND ROLL SPOILER INBD HYD CAUTION LIGHT ILLUMINATED. INSTALLED TEMP FLEX LINE IAW SP 20.2 FROM PRESSURE PORT OF NR 1 ENGINE DRIVEN HYD PUMP TO FIREWALL. SERVICSDR HNAA2013012800026Bulb · inoperativeEMERGENCY SIDEWALL TOP SIGN AT ROW 1DF IS DIM. R & R EMERGENCY LIGHT AT TOP SIDEWALL SIGN. OPS CHECKED GOOD.SDR HNAA2013012800023Apu · smokeWITH APU BLEEDS TURNED ON, FLIGHT DECK FILLED WITH SMOKE. ALL OTHER APU INDICATIONS AND OPERATIONS NORMAL AT THIS TIME. VERIFY FUEL VALVE CLOSED. PULLED AND COLLARED CIRCUIT BREAKER N8 ON RT MAIN BUSS.SDR CA130128023Line · leaking(CAN) DURING AN L-CHECK, MAINTENANCE DISCOVERED A FUEL LEAK FROM A RT WING REFUEL/TRANSFER LINE, IPC REF 28-23-00, FIG 15, ITEM 140. INSPECTION OF THE LINE REVEALED A PINHOLE IN AN AREA WITH PITTING DUE TO CORROSION. THE LINE WAS REPLACED AND LEAK CHECK PERSDR HNAA2013012500020Warning Light · false activationUPON GEAR RETRACTION, WOW CAUTION LIGHT, NOSE GEAR UNSAFE AND LT AND RT AMBER GEAR DOOR LIGHTS ILLUMINATED. RACKED PSEU. CYCLED GEAR NUMEROUS TIMES. NO DEFECTS NOTED.SDR HNAA2013012500019Lever · out of adjustWITH BOTH CONDITION LEVERS SELECTED TO MAX ON LANDING WITH TORQUE SELECTED BETWEEN 20 TO 40 PERCENT MAX. NP WAS 1150 TO 1165. ENGINES RIGGED IAW WC 76-00-01. GROUND RAN ACFT TO MAX PROP AND WAS FOUND TO BE WITHIN LIMITS IAW SRT MANUAL.SDR HNAA2013012500018Pulley · stiffIN FLIGHT, WITH MORE THAN 10 DEGREES RT DEFLECTION OF THE YOKE CONTROL, FORCE WAS HEAVY. INSPECTED AND FOUND 2 GUIDE PULLEYS STIFF FOR THE RT WING. REMOVED BOTH PULLEYS. YOKES MOVE FREELY. PULLEYS REMOVED WERE AT RT SIDE OF GUSTLOCK. RE-VERFIED CABLE TENSISDR HNAA2013012400021Control Cable · out of adjustDURING DESCENT ACFT ENCOUNTERED MODERATE WIND SHEAR CAUSING ACFT TO EXCEED 260 KNOTS FOR 3 SECONDS. NO LOSS OF CONTROL JUST MODERATE BUFFETING. CHECKED CABLE TENSION OF RUDDER CONTROL SYS. FOUND TENSION LOW ON RUDDER CABLE CIRCUIT. ADJUSTED IAW MM 27-20-00SDR HNAA2013012500017Bulb · failedROW 5 CEILING EMERGENCY LIGHT IS INOPERATIVE. REMOVED LENS. R & R BULB, AT SAID LOCATION. REINSTALLED LENS.SDR HNAA2013012500016Bulb · inoperativeEMERGENCY EXIT LIGHT ABOVE ROW 1 EMERGENCY EXIT HAS NUMEROUS BULBS THAT ARE INOP. REMOVED EXIT LIGHT LENS. SOLDERED SEVERAL LIGHT SOCKETS FOR INDIVIDUAL BULBS THAT WERE MISSING. REINSTALLED LIGHT ASSY AND LIGHT LENS COVER.SDR HNAA2013012500015Light · inoperativeFORWARD RT EMERGENCY LIGHT INOPERATIVE. REINSTALLED FORWARD RT EXIT.SDR HNAA2013012500014Wire Harness · saturatedEMERGENCY LIGHTS FLICKERS WITH PROP HEAT ON. OK WITH OFF. OK AT 1050 NP. UNABLE TO DUPLICATE PROBLEM ON GROUND RUN. INSPECTED BOTH PROP BLADE LEADS CHECKED GOOD. NR 1 ENGINE HARNESS FROM BRUSH BLOCK P5 TO J4 SOAKED WITH OIL. REPLACED HARNESS. GROUND RAN ASDR HNAA2013012500013Brush Block · intermittentEMERGENCY LIGHTS FLICKER WITH PROP HEAT ON. OK AT 1050 NP. R & R NR 1 AND NR 2 BRUSH BLOCK ASSY'S IAW DASH 8 MM 61-10-11. GROUND RAN ACFT WITH NO DEFECTS NOTED. OPS CHECKED GOOD AT THIS TIME.SDR HNAA2013012500012Brush Block · dirtyALL CABIN EMERGENCY LIGHTS FLICKERING, WHEN PROP AT 1050, OP HEAT ON AND PHASE 2A. EMERGENCY LIGHTS DO NOT FLICKER WHEN SELECTED TO 900. CLEANED AND INSPECTED PROP BRUSH BLOCKS ON BOTH ENGINES IAW MM 61-10-11. OPS CHECKED GOOD.SDR HNAA2013012500011Control Box · inoperativeEMERGENCY LIGHTS WILL NOT TURN ON. RERACKED EMERGENCY LIGHT CONTROL BOX. SYSTEM OPS CHECKED GOOD. OK FOR SERVICE.SDR CA130128014Engine · vibration(CAN) IT WAS REPORTED THERE WAS LIGHT VIBRATION ON THE NR 1 ENGINE. TROUBLESHOOTING FOUND A FUEL LEAK AT THE FUEL FLOW DIVIDER VALVE DRAIN AT ANY POWER SETTING CONDITIONS. THE LEAK RATE WAS 200ML OF FUEL AFTER A 5 MINUTES RUN AT IDLE, LOW POWER FEATHER.SDR HNAA2013012200009Bulb · burned outSIDEWALL EMERGENCY LIGHT AT ROW 1DF & 4DF INOPERATIVE. REMOVED LENS COVER, R & R BULBS AND REINSTALLED LENS.SDR CA130123006Wire Harness · chafed(CAN) DURING THE CLIMB THROUGH 13,000 FT THE CARGO SMOKE WARNING LIGHT CAME ON AND THE CREW NOTICED AN ODOR IN THE CABIN. ENGINE BLEEDS WERE TURNED OFF IAW THE QRH AND THE ACFT RETURNED TO THE DEPARTURE AIRPORT. THE SMOKE WARNING LIGHT EXTINGUISHED DURING THSDR CA130121004Receptacle · melted(CAN) DURING CLIMB, THE F/A REPORTED A BURNING RUBBER ODOR IN THE FORWARD CABIN. THE ACFT RETURNED AND LANDED WITHOUT FURTHER INCIDENT. DURING TROUBLESHOOTING, MAINTENANCE FOUND TRACES OF MELTED RUBBER ON THE HOT WATER JUG ELECTRICAL RECEPTACLE. THE RECEPTASDR CA130122010Shock Mount · worn(CAN) ALL PILOT`S AND CO-PILOT`S COCKPIT INSTRUMENTS WERE REMOVED OFF THE CENTER INSTRUMENT MOUNTING FRAME, PN 83910021-001 TO FACILITATE A DETAILED VISUAL INSPECTION OF THE WINDSHIELD LOWER SILL TIE BEAM AND THE FORWARD PRESSURE TENSION FITTINGS FOR TASKS 531SDR CA130121005Actuator · cracked(CAN) DURING TAXI FOR TAKEOFF, THE NR 1 HYDR SYS, PRESSURE AND QUANTITY, DEPLETED. ACFT WAS TOWED BACK TO THE GATE. UPON MAINTENANCE INSPECTION, IT WAS FOUND THAT THE NR 2 INBD SPOILER ACTUATOR WAS CRACKED. THE ACTUATOR WAS REPLACED AND THE APPLICABLE LEAK ASDR CA130201002Ballast · odor(CAN) DURING FLIGHT, ODOR OF ELECTRICAL BURNING WAS DETECTED IN ROW 8 OF THE CABIN NEAR THE SIDE WALL LIGHTS. THE LT AND RT SIDE WALL LIGHT FIXTURE ASSEMBLIES WERE REPLACED AND SYSTEM CHECKED SERVICEABLE. NO MORE ELECTRICAL BURNING ODOR IN THE CABIN.SDR HNAA2013011400008Bulb · inoperativeSIDEWALL LIGHT IS DIM AT ROW 4DF. R & R BULB.SDR HNAA2013011400006Line · rupturedNR 2 HYD QTY AT .5 WITH FLUID LEAKING IN NR 2 NACELLE WITH RUDDER ISOLATION VALVE CAUTION LIGHT ILLUMINATED. INSPECTED NR 2 WHEEL WELL AND FOUND HYD LINE FOR AFT GEAR DOOR FROM ELECTRIC SEQUENCE VALVE ACTUATOR RUPTURED. INSTALLED TEMP FLEX LINE IAW SP20.1 SSDR HNAA2013011400005Ballast · smokeSMOKE NOTICED AROUND ROW 1DF OVERHEAD LIGHT ASSY. REPLACED BALLAST.SDR HNAA201301100004Light · failedFLOOR EMERGENCY LIGHT IS INOPERATIVE AT ROW 7. R & R LIGHT ASSY IAW MM 33-52-00. OPS CHECKED GOOD.SDR HNAA2013010900001Inverter · failedOILY BURNING SMELL AROUND FORWARD CABIN AREA AND FLIGHT DECK. FOUND AUX INVERTER FAILED. R & R AUX INVERTER. OPS CHECKED GOOD.SDR HNAA201301090003Bulb · failedEMERGENCY SIDEWALL LIGHT IS INOPERATIVE AT ROW 4AC. R & R BULB.SDR CA130110001Adapter · restricted(CAN) ON DESCENT, FLIGHT CREW NOTICED A STRONG BURNING PLASTIC ODOR IN THE COCKPIT. AN EMERGENCY WAS DECLARED AND FLIGHT CREW DONNED THEIR OXYGEN MASK. SOME ELECTRICAL SYS AND ENGINE BLEEDS WERE TURNED OFF. AFTER FEW MINUTES THE ODOR DISSIPATED. ACFT LANDEDSDR HNAA2013010701153Bulb · inoperativeONE RED EMERGENCY LIGHT AT ROW 1 IS INOPERATIVE. R & R BULB AT ROW 1. REINSTALLED PLASTIC FLOOR TRIM AND COVER.SDR HNAA2013010701152Bulb · failedFLOOR EMERGENCY LIGHT IS INOPERATIVE, 7TH FROM FRONT. R & R BULB. OPS CHECKED GOOD. REINSTALLED FLOOR LENS COVER.SDR HNAA2013010701151Lamp · inoperativeEMERGENCY CEILING LIGHT AT ROW 10 IS DIM. REPLACED LAMP, INSTALLED COVER. OPS CHECKED GOOD.SDR HNAA2013010701150Switch · failedF/A EMERGENCY LIGHT SWITCH ON LIGHT INOPERATIVE. R & R EMERGENCY LIGHT SWITCH S2 IAW WIRING MANUAL 33-51-00. BOTH OPS CHECKED GOOD.SDR HNAA2013010701149Gauge · erraticNR 1 ENGINE FUEL TEMP GAUGE IS ERRATIC. REPLACED GAUGE. DID NOT FIX. REINSTALLED ORIGINAL GAUGE. R & R NR 1 ENGINE FUEL TEMP BULB IAW AMM 71-00-02. RAN ACFT. OPS CHECKED GOOD AT THIS TIME. OK FOR SERVICE.SDR HNAA2013010701148Pseu · warning lightAFTER TAKEOFF, WITH GEAR UP, ALL UNSAFE LIGHTS FOR GEAR ARE ON. ALTERNATE INDICATION SHOWS THAT ALL ARE UP AND LOCKED. EXTENDED GEAR WITH ALTERNATE EXTENSION. JACKED ACFT. SWUNG GEAR SEVERAL TIMES. NO DEFECTS NOTED. R & R PSEU IAW MM 32-61-50. OPS CHECKSDR CA130117005Oil System · leaking(CAN) DURING REVENUE FLIGHT, ON APPROACH, PILOT REPORTED OIL MIST AND ODOR IN CABIN, DECLARED AN EMERGENCY. A SINGLE ENGINE UNEVENTFUL LANDING WAS PERFORMED. ON GROUND INVESTIGATION, FOUND OIL STAINING AND DROPLETS ON PLENUM AND DIFFUSER. ENGINE TO BE REPLAC
Back to Boeing DHC-8-102