Boeing DHC-8-102
Service difficulty reports · 9,272
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DHC8102' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DHC8102' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2011122700439Bulb · failed1 RED FLOOR EXIT LIGHT AT ROW 1 IS INOPERATIVE. R & R 1 RED FLOOR EXIT LIGHT BULB AT ROW 1.SDR HNAA2011122700438Light · damagedMISSING EMERGENCY LIGHT ARROW ON LOWER LIGHT. R & R LIGHT MODULE WITH NEW. OPS CHECKED GOOD.SDR CA111223004Stringer · cracked(CAN) MANY WING STR STRAPS AND SPLICES FOUND CRACKED OR BROKEN ON LOWER SKINS STA YW 191.000 TO 200.000, STR 12 TO 18, ON BOTH WINGS 1 CRACK FOUND ON A SPLICE DURING THE VISUAL INSPECTION, CARD 05-66-13I, ZONAL FUEL TANK INSPECTION, DURING INVESTIGATION WE FOSDR HNAA2011122300437Lamp · failedAFT EMERGENCY FLOOR PATH LIGHT IS INOPERATIVE AT ROW 9. R & R LAMP MODULE. OPS CHECKED GOOD.SDR HNAA2011122300436Bulb · failedBACKLIGHT IN EMERGENCY LIGHT BUTTON AT F/A PANEL IS INOPERATIVE. REMOVED SWITCH COVER, RELAMPED. REINSTALLED SWITCH COVER. OPS CHECKED GOOD.SDR HNAA2011122000429Indicator · inoperativeNR1 OIL TEMP FLUX 30-50-DEGREE C. AND NR1 FUEL TEMP AT 10 DEGREE C. RAN ACFT, NR 1 OIL TEMP FLUXED CONTINUOUSLY. NR 1 FUEL TEMP READ 10 DEGREES LOWER THAN NR 2. NO FLUX NOTED. REPLACED FUEL INDICATOR,FUEL TEMP READ CONSISTANT ON BOTH ENGINES. CHECKED WIRINGSDR HNAA2011122000435Light · failedOVERHEAD LIGHT AT ROW 2DF FAILED. R & R LAMP HOLDER, BULB AND BALLAST AT SEAT 2DF. OPS CHECKED GOOD.SDR HNAA2011122000434Skin · cracked6 CRACKS FOUND IN RT WING LOWER SKIN PANEL. OPEN.SDR HNAA2011122000433Module · misinstalledFLOOR LEVEL MID EXIT EMERGENCY LIGHT MODULE ARE POINTING IN WRONG DIRECTION. REALIGNED FLOOR LIGHT MODULE. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2011122000432Battery Pack · failedOVERHEAD EMERGENCY LIGHT AT ROW 4 IS INOPERATIVE. R & R BATTERY PACKS PS2 AND PS4. OPS CHECKED GOOD IAW 33-51-00. OK FOR SERVICE.SDR HNAA2011122000430Lamp · failedNR 2 FROM FRONT EMERGENCY FLOOR PATH LIGHT IS INOP. RELAMPED NR 2 FROM THE FRONT EMERGENCY FLOOR PATH LIGHT. OPS CHECKED GOOD.SDR HNAA2011122000428Connector · damagedEMERGENCY FLOOR LIGHTS ARE INOP AT ROW 1DF AND 4DF. REMOVED BATTERY IN ROW 3 RT CEILING, FIXED 2 EMERGENCY LIGHTS IN ROW 1DF. PUSHED PIN IN CONNECTOR FOR LIGHTS IN ROW 4DF. RESEATED, OPS CHECKED GOOD.SDR HNAA2011121600427Power Lever · out of trimNR 1 ENGINE POWER LEVER LAGS DURING TAKEOFF AND IN CRUISE. GROUND RAN ACFT, RETRIMMED ENGINES, OK FOR CONTINUED SERVICE.SDR HNAA2011121600426Gyro · failedSTANDBY ATTITUDE INDICATOR CONTINUE TO TUMBLE AFTER PULLING ERECT KNOB. R & R STANDBY ATTITUDE GYRO. TESTED GOOD IAW MM 34-22-01.SDR HNAA2011121300425Contactor · failedAPU WARNING LIGHT AND APU STARTER LIGHT ILLUMINATED, WHILE APU WAS RUNNING AND AFTER NR 1 ENGINE START. MX VERIFIED APU CONTACT WAS NOT WELDED. MX INSPECTED APU AND COMPARTMENT. NO DEFECTS NOTED. R & R APU START CONTACTOR IAW MM 24-31-09. OPS CHECKED GOOSDR HNAA2011121300424Handle · malfunctionedPARKING BRAKE HANDLE WILL NOT SET. WHEN PARK BRAKE HANDLE IS MOVING TOWARD SET, GUST LOCK RELEASES. TIGHTENED HARDWARE ON PARKING BRAKE AND GUST LOCK STOP BRACKET. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2011121300423Igniter · failedNR 1 ENGINE WILL NOT START ON TAXI OUT. ITT STAYED AT 60 DEGREES. 3 ADDITIONAL ATTEMPTS ENGINE WILL NOT START. ACFT RETURNED TO GATE. R & R NR 1 ENGINE IGNITORS IAW MM 72-01-20. GROUND RAN ACFT. OPS CHECKED NORMAL AT THIS TIME.SDR CA111215004Line · chafed(CAN) DURING DESCENT, THE FLIGHT CREW OBSERVED A RAPID DROP OF THE NR 1 HYDRAULIC SYS PRESSURE. AN EMERGENCY WAS DECLARED AND THE ACFT LANDED WITHOUT FURTHER INCIDENT. THE FOLLOWING SYSTEMS WERE DIRECTLY AFFECTED BY THE LOST OF THE NR 1 HYD SYSTEM: WING FLAPSDR CA111214015Engine · power loss(CAN) DURING CRUISE BOTH ENGINES HAD A 10-15 PERCENT ROLL BACK FOR 2-3 SEC. BEFORE RECOVERING SET POWER ON 2 SEPARATE OCCASIONS. THE FLIGHT LANDED UNEVENTFULLY. GROUND RUNS COULD NOT REPLICATE THE PROBLEM AND TROUBLESHOOTING IS ON-GOING.SDR CA111212003Lead · burned(CAN) DURING THE APPROACH SPARKS WERE OBSERVED COMING FROM THE LT PROPELLER SPINNER. THE CAUTION LIGHT PANEL & THE BLADE ANTI-ICING SYSTEM WAS CHECKED BY THE FLIGHT CREW & NO ABNORMALITIES WERE DETECTED. MAINTENANCE CREW FOUND A LEAD BURN OUT FROM THE LT NR SDR CA111216003Engine · unknown(CAN) DURING CRUISE AT TWO OCCASIONS BOTH ENGINES TORQUE MOMENTARILY ROLLED BACK OF 10-15 PERCENT. THE ACFT LANDED TO DESTINATION WITHOUT FURTHER INCIDENT AND THE ACFT WAS REMOVED FROM SERVICE. MAINTENANCE WAS UNABLE TO REPRODUCE THE POWER LOSS. ELECTRICAL SDR HNAA2011121200422Bulb · burned outLT FWD FUSELAGE THRESHOLD EMERGENCY LIGHT INOP. R & R LIGHT BULB IAW 33-51-00.SDR HNAA2011120900421Brush Block · meltedEMERGENCY LIGHTS FLICKERED IN FLIGHT. MX INSPECTED AND FOUND NR 2 BRUSH BLOCK MELTED. R & R NR 2 ENGINE BRUSH BLOCK IAW 61-10-11. GROUND RAN ACFT. OPS CHECKED GOOD.SDR HNAA2011120900420Switch · lack of lubeBAG DOOR WARNING LIGHT ILLUMINATED WITH ACFT PRESSURED. LIGHT WENT OUT DURING DEPRESSURIZING AND BLEEDS OFF. FOUND AFT BAG DOOR PROXIMITY SWITCH STUCK IN WRONG POSITION. CLOSED AND LUBED SWITCH. OPS CHECKED GOOD.SDR CA111208011Gust Lock · defective(CAN) AFTER REMOVING THE CENTER WING GUST LOCK LEVER, HOUSING, DURING RECTIFICATION OF AN UNRELATED DEFECT, IT WAS NOTED THAT THERE WAS CORROSION AROUND THE PIVOT BORE BUSHINGS. UPON FURTHER INVESTIGATION, MORE CORROSION WAS DISCOVERED BETWEEN THE BUSHINGS IN SDR CA111214005Engine · power loss(CAN) DURING REVENUE FLIGHT, PILOT REPORTED POWER ROLL BACK. ENGINE REMAINED IN OPERATION, HOWEVER, AS SOME ENGINE PARAMETERS NEVER RECOVERED, PILOT ELECTED TO PERFORM AN AIR TURNBACK TO AIRPORT.SDR CA111206014Actuator · worn(CAN) DURING HEAVY MAINTENACE, INSPECTION OF THE LT INBD FLAP ACTUATOR, NR 1 POSITION, REVEALED EXCESSIVE PLAY IN THE INPUT SHAFT. THE ACTUATOR HAS BEEN SENT TO THE VENDOR FOR INSPECTION/REPAIR. A SERVICEABLE ACTUATOR WAS INSTALLED IAW THE AMM. THIS SDR WILLSDR HNAA2011120600417Threshold · corrodedPAX DOOR THRESHOLD FOUND CORRODED. R & R PAX DOOR THRESHOLD WITH SOLID RIVETS. CARRIED OUT HFEC INSP ON REWORKED AREA IAW RD8-53-8921. NO CRACK INDICATION FOUND. REPAIR WAS DONE IAW SRM 51-42-05.SDR HNAA2011120600416Fitting · corrodedMACHINE FITTING LAVATORY POINT FOUND CORRODED. LAVATORY SERVICE POINT FITTING IS LOCALLY FRABRICATED IAW SAMPLE AND DWG 85320980 AND EA01-09121. WS REPAIRED IAW SRM 51-42-05, RD8-51-102 AND AMM20-14-01.SDR HNAA2011120600415Angle · crackedANGLE REINFORCEING BOTTOM FRAME AT STA.X222 BETWEEN STR 23S AND 25S FOUND CRACKED. ANGLE REINFORCING BOTTOM FRAME REPAIRED, LOCALLY FRABRICATED IAW SAMPLE AND DWG 85320395. REPAIR WAS DONE IAW SRM 53-20-21.SDR HNAA2011120600414Battery Pack · failedTWO RED EMERGENCY LIGHTS ARE OUT IN ROW 1 AND 4. R & R BATTERY PACK AT P-2. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2011120600413Bulb · burned outFLOOR PATH EMERGENCY LIGHT IS INOP AT ROW 1DF. R & R BULB AND ROW 1DF, OPS CHECKED GOOD.SDR CA111208013Switch · damaged(CAN) AFTER LANDING FLIGHT/TAXI SPOILER SWITCH IN TAXI MODE FAILED AFTER LANDING DURING TAXI TO THE GATE. FLIGHT-TAXI SWITCH WOULD NOT REMAIN LATCHED. REPLACED SPOILER FLT TAXI SWITCH AND RETURNED ACFT TO SERVICE.SDR CA111205006Solenoid Valve · failed(CAN) WHEN THE LANDING GEAR WAS SELECTED UP AFTER DEPARTURE, ALL OF THE NR 2 HYD SYSTEM FLUID WAS LOST AND THE LANDING GEAR DID NOT GO UP BUT REMAINED DOWN AND LOCKED. THE ACFT LANDED SAFELY. MAINTENANCE INVESTIGATION REVEALED THAT THE RT LANDING GEAR DOOR SSDR HNAA2011120100411Brush Block · failedEMERGENCY LIGHTS FLICKERED DURING CLIMB. R & R NR1 AND NR 2 PROP BRUSH BLOCK IAW MM 61-10-11. COMPLIED WITH WORKCARD 33-50-03Q. EMERGENCY LIGHT SYS OPS CHECKED GOOD.SDR HNAA2011120100410Connector · looseNR 1 PITOT HEAT FAILED INFLIGHT WITH ASSOCIATED DADC AND AHRS DISCREPENCIES. REMOVED LT PITOT PROBE AND FOUND CONNECTOR LOOSE. REMOVED, CLEANED AND RESEATED CONNECTOR. OPS CHECKED GOOD. ALL DADC AND AHRS DISCREPENCIES CLEARED. ALL SYS CHECKED GOOD.SDR HNAA2011120100409Control Box · failedFLOOR EMERGENCY LIGHTS FLICKERED DURING CLIMB OUT. R & R LIGHT CONTROL BOX IAW WORKCARD 33-50-03Q.SDR CA111209001Connector · shorted(CAN) DURING CLIMB THE LT ELEVATOR HORN HEAT CAUTION LIGHT CAME ON. THE ACFT WAS ALREADY OPERATING ON THE SECONDARY HEAT ELEMENT AND THUS RETURNED TO THE MTC BASE IT DEPARTED FROM. DURING MTC T/S IT WAS NOTICED THAT ALL OF THE NAVIGATION LIGHTS WERE U/S ALSO ASDR CA111130008Indicator · malfunctioned(CAN) MAINTENANCE NOTICED DISPLAY ON VSI/TRA TCAS INDICATOR VERY DIM AND FLICKERING. VSI REPLACED WITH SERVICEABLE UNIT. ACFT RETURNED TO SERVICE.SDR CA111129009Panel · malfunctioned(CAN) DURING THE APPROACH, THE LT ADVISORY DISPLAY PANEL ID802, STARTED TO FLASH & THE FLIGHT CREW NOTICED AN ELEC SMELL IN THE COCKPIT. THE APPROACH WAS CARRIED ON & THE ACFT LANDED WITHOUT FURTHER INCIDENT. AT THE TIME OF THE INCIDENT, THE ACFT WAS OPERATISDR HNAA2011112900406Bulb · failedNR 10 FLOOR PATH LIGHT IS INOPERATIVE. R & R BULB.SDR HNAA2011112800402Warning Light · false activationDURING CLIMBOUT RECEIVED RT AC BUS CAUTION LIGHT WITH ASSOC OTHER CAUTION LIGHTS. CLEANED CONNECTOR NR 2 AC GEN AND AT RT AC CONTACTOR BOX. INSPECTED NR 2 BRUSH BLOCK WITH NO DEFECTS NOTED. GROUND RAN A/C WITH NO DEFECTS NOTED AT THIS TIME. OK 4 SERVICE.SDR HNAA2011112800399Access Panel · corrodedLT AND RT AUXILIARY FUEL PUMP LOWER ACCESS PANEL FOUND CORRODED. HFEC & BOND TEST CARRIED OUT ON REWORKED AREAS IAW RD8-57-1907 NO CRACK INDICATION & NO DISBOND FOUND. LT AND RT AUXILIARY FUEL PUMP LOWER ACCESS PANEL BLEND WITHIN LIMITS IAW RD8-57-1907. RT SSDR HNAA2011112800401Brush Block · wornDURING CLIMB RT AC BUSS C/L ILLUMINATED, ASSOCIATED WITH RT ELEVATOR HORN HEAT, RT STALL WARNING C/L, AND RT TRU C/L. OCCURRED APPROX 1 MIN AFTER SELECTING ICING SYS ON. INSPECTED NR 2 AC CONTACTOR BOX & NR 2 AC GEN. NO DEFECTS NOTED. R & R NR 2 BRUSH BLOCK SDR HNAA2011112300398Bracket · crackedON A 2 C-CHECK, WHILE PERFORMING A VISUAL INSPECTION OF RT WING AREA (STA YW45.00 TO WING BOX OTBD END) IAW WORK CARD 04-55-31I, RT WING OTBD SPOILER ACTUATOR BRACKET FOUND CRACKED.SDR CA111124001Pressure Switch · failed(CAN) DURING TAXI TO THE GATE THE NR 2 ENGINE FUEL FILTER BYPASS LIGHT ILLUMINATED. THE NR 2 DIFFERENTIAL PRESSURE SWITCH WAS REPLACED ALONG WITH THE NR 2 HP FUEL FILTER, PN 7589141. GROUND RUNS WERE CARRIED OUT AND THE ACFT WAS RETURNED TO SERVICE.SDR CA111122004Bearing Race · broken(CAN) DURING REPLACEMENT OF THE ACFT LT PROPELLER ACTUATOR, THE ENGINEER NOTICED THAT THE NR 1 BLADE, OUTER RACE LOCATED INSIDE THE PROPELLER HUB WAS BROKEN. VISUAL INSPECTION OF THE NR 1 BLADE OUTER RACE, PICTURES 1 & 2, REVEALED PLATING MISSING ON THE LOWERSDR HNAA2011112300397Circuit Breaker · trippedRT WING INSPECTION LIGHT POPS CIRCUIT BREAKER. INSPECTED CONTROL PANEL AND WIRING IN LOWER NR 2 COWLING. NO DEFECTS FOUND. CLEANED CONTROL PANEL AND R & R BULB AND OPS CHECKED GOOD.SDR HNAA2011112300396Warning Light · illuminatedRIGHT AC BUSS CAUTION LIGHT ON IN FLIGHT WITH ASSOCIATED CAUTION LIGHTS. STALL WARNING, ELEVATOR HORN HEAT, AND RT TRU. INSPECTED CONNECTORS ON RT AC CONTACTOR BOX. INSPECTED CONNECTORS IN RT WING ROOT. INSPECTED RT PROPELLER AND BRUSH BLOCK, NO DEFECTS NOTSDR HNAA2011112300395Bulb · inoperativeROW 1 AND ROW 8 EMERGENCY FLOOR PATH LIGHTS ARE INOPERATIVE. R & R BULBS. OPS CHECKED GOOD.
Back to Boeing DHC-8-102