Boeing MD-11F
Service difficulty reports · 31,317
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD11F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2021030266290Skin · corrodedINSPECTION TYPE:3CL/H WING I/B UPPER T/E SURFACE SKIN HAS 4 AREAS OF CORROSION AT STA. XORS. 442, 447, 413 & 430.REPAIRED CORRODED L/H WING UPPER SKIN IAW VT-SAA EA 011-5730-01-A8893 REV. I/R AND UPS EO MD11-5710-79490-A. (MINOR)SDR IPXA2021022766171Landing · corrodedINSPECTION TYPE:3CRT WING SPOILER PANEL SILL HAS CORROSION BETWEEN XOSP 595 TO XOSP 656.REPAIRED CORRODED RT WING SPOILER PANEL SILL BETWEEN XOSP 595 TO XOSP 656 IAW MD-11 SRM 57-50-02 REPAIR 10, FIGURE 201. (MAJOR)SDR IPXA2021022766170Landing · corrodedINSPECTION TYPE:3CLT WING SPOILER PANEL SILL HAS CORROSION BETWEEN XOFH 453 TO XOSP 490.REPAIRED CORRODED LT WING SPOILER PANEL SILL BETWEEN XOFH 453 TO XOSP 490 IAW MD-11 SRM 57-50-02 REPAIR 10, FIGURE 201. (MAJOR)SDR IPXA2021022766169Landing · corrodedINSPECTION TYPE:3CLT WING SPOILER PANEL SILL HAS CORROSION BETWEEN XOSP 603 TO XOSP 638.REPAIRED CORRODED LT WING SPOILER PANEL SILL BETWEEN XOSP 603 TO XOSP 638 IAW MD-11 SRM 57-50-02 REPAIR 10, FIGURE 201. (MAJOR)SDR IPXA2021022766167Doubler · crackedINSPECTION TYPE:3CRT WING FIXED L/E BEADED DOUBLER IS CRACKED BETWEEN XOS 879 TO XOS 883.REPAIRED CRACKED RT WING FIXED L/E BEADED DOUBLER BETWEEN XOS 879 TO XOS 883 IAW MD-11 SRM 57-40-02 REPAIR 15, FIGURE 205. (MAJOR)SDR IPXA2021022766166Doubler · crackedINSPECTION TYPE:3CRT WING FIXED L/E BEADED DOUBLER IS CRACKED BETWEEN XOS 728 TO XOS 734.REPAIRED CRACKED RT WING FIXED L/E BEADED DOUBLER BETWEEN XOS 728 TO XOS 734 IAW MD-11 SRM 57-40-02 REPAIR 15, FIGURE 205. (MAJOR)SDR IPXA2021022766165Doubler · crackedINSPECTION TYPE:3CRT WING FIXED L/E BEADED DOUBLER IS CRACKED BETWEEN XOS 692 TO XOS 703.REPAIRED CRACKED RT WING FIXED L/E BEADED DOUBLER BETWEEN XOS 692 TO XOS 703 IAW MD-11 SRM 51-40-02 REPAIR 15, FIGURE 205. (MAJOR)SDR IPXA2021022666120Intercostal · crackedINSPECTION TYPE:C3FWD CARGO COMPT INTERCOSTAL CRACK BETWEEN STA.6-30 AND STA.6-50 LON 42L.REMOVED,FABRICATED AND REPLACED CRACKED INTERCOSTAL IAW SRM 51-35-01 AND SRM 51-33-01 (MINOR)SDR IPXA2021022666123Intercostal · crackedINSPECTION TYPE:C3FWD CARGO COMPARTMENT INTERCOSTAL CRACK BETWEEN STA.6-30 AND STA.6-50 LON 42R.REMOVED,FABRICATED AND REPLACED CRACKED INTERCOSTAL IAW SRM 51-31-01 AND SRM 51-33-01 (MINOR).SDR IPXA2021022366010Stiffener · crackedINSPECTION TYPE :3C RT WING L/E PANEL 618FB AFT LANDING SUPPORT STIFFENER IS CRACKED. REMOVED AND REPLACED RT WING L/E PANEL 618FB AFT LANDING SUPPORT STIFFENER IAW MD-11 SRM 51-33-01. (MINOR)SDR IPXA2021022466079Support Angle · crackedINSPECTION TYPE: C3 LT WING REAR SPAR VERTICAL SUPPORT ANGLE CRACK FWD OF I/B AILERON. REMOVED AND REPLACED CRACKED VERTICAL SUPPORT ANGLE IAW SRM 51-35-01 AND 51-33-01 (MINOR).SDR FDEA202102080309Seat Track · wornCABIN - SEAT TRACK AT STATION 5-93 LEFT HAND X = 27.5 FOUND WITH CROWN WORN . CABIN - AT LEFT HAND SEAT TRACK STATION 5-93 , X = 27.5 WORN CROWN EVALUATED AND FOUND EXCEEDED LIMIT AS PER SRM 53-00-52-1A FIGURE 101 ALLOWABLE DAMAGE 1. CROWN WORN SEAT TRACKSDR FDEA202102080311Seat Track · wornCABIN - SEAT TRACK AT STATION 1541 RIGHT HAND X = - 8.5 FOUND WITH CROWN WORN . CABIN - AT RIGHT HAND SEAT TRACK STATION 1541 , X = - 8.5 WORN CROWN EVALUATED AND FOUND EXCEEDED LIMIT AS PER SRM 53-00-52-1A FIGURE 101 ALLOWABLE DAMAGE 1 . CROWN WORN SEAT SDR FDEA202102080310Seat Track · wornCABIN - SEAT TRACK AT STATION 1541 LEFT HAND X = 27.5 FOUND WITH CROWN WORN. CABIN - AT LEFT HAND SEAT TRACK STATION 1541 , X = 27.5 WORN CROWN EVALUATED AND FOUND EXCEEDED LIMIT AS PER SRM 53-00-52-1A FIGURE 101 ALLOWABLE DAMAGE 1 . CROWN WORN SEAT TRACK SDR IPXA2021020865471Skin · crackedINSPECTION TYPE:N/ARH AIR CONDITIONING DOOR JAMB CORNER SKIN CRACK REPAIRREPAIRED PER EO MD11-5330-78847-C.SDR FDEA202102080316Floor Panel · wornMAIN CABIN FLOOR PANEL 261CF HOLES AND CHAFFING DAMAGE TO UPPER FACE SHEET OF FLOOR BOARD STA.1219 FABRICATED NEW PANEL 261CF PER DRW SRZ-25-005SDR IPXA2021030266312Doubler · crackedINSPECTION TYPE:3CL/H WING FIXED L/E BEADED DOUBLER IS CRACKED BETWEEN STA. XOS.698.1274 TO 703.5466.REPAIRED CRACKED L/H WING FIXED L/E BEADED DOUBLER BETWEEN STA. SOX. 698.1274 TO 703.5466 IAW SRM 57-40-02 REPAIR 15 FIG. 205. ( MAJOR)SDR IPXA2021022766164Doubler · crackedINSPECTION TYPE:3CLT WING FIXED L/E BEADED DOUBLER IS CRACKED BETWEEN XOS 789 TO XOS 795.REPAIRED CRACKED LT WING FIXED L/E BEADED DOUBLER BETWEEN XOS 789 TO XOS 795 IAW MD-11 SRM 57-40-02 REPAIR 15, FIGURE 205. (MAJOR)SDR IPXA2021020865469Switch · intermittentINSPECTION TYPE:NALEFT INTERIOR CABIN ENTRY DOOR SWITCH INTERMITTENTREMOVED AND REPLACED OPEN LIMIT C/W AND CLOSE LIMITS S/W REF WDM 52-11-01 OPERATIONAL CHECK OF L1 DOOR OPS CHECKS GOOD REF M/M CH 52-10-01 IPC 52-11-70-01-I 005-35.SDR IPXA2021020765411Solenoid · malfunctionedL1 DOOR WILL NOT CLOSE ELECTRONICLLY WITH EITHER INDOOR OR OUTDOOR SWITCHES. R/R'D L1 DOOR SOLENOID S2-730 IAW BOEING MD SWPM 20-00-09 AND MD11 WDM 52-11-01 IN REF TO UPS M734971. PERFORMED SATIS OPS CHECK OF DOOR REF MD11 AMM 52-11-02-010-802 & 52-11-02-41SDR IPXA2021030966633Doubler · chafedINSPECTION TYPE:3CTAILCONE INTERNAL PRODUCTION DOUBLER IS CHAFED AT STA 2160 AND X=-36.5.REPAIRED TAILCONE IAW UPS EO MD11-5350-66790-A. (MINOR)SDR IPXA2021030966634Doubler · chafedINSPECTION TYPE:3CTAIL CONE INTERNAL PRODUCTION DOUBLER IS CHAFED AT STA. 2165 AND X= 36.5.REPAIRED TAIL CONE IAW UPS EO MD11-5350-66790-A. (MINOR)SDR IPXA2021020865455Chiller · odorINSPECTION TYPE:NASTRONG CHEMICAL ODOR IN COCKPIT.DID NOT NOTICE A CHEMICAL SMELL BUT DID NOTICE A STRONG ELECTRICAL SMELL AROUND COURIER SEATS AND GALLEY AREA. HAS HISTORY OF REFRIGERATOR NOT WORKING AND GIVING OFF A BURNING SMELL. R&R REFRIGERATOR IAW AMM 25SDR IPXA2021022666121Stiffener · crackedINSPECTION TYPE:C3RH MLG W/W 3RD VERTICAL STIFFENER CRACK AT LWR END.REMOVED AND REPLACED CRACKED VERTICAL STIFFENER IAW SRM 51-33-02 AND SRM 51-35-01 (MINOR).SDR IPXA2021022366009Stiffener · crackedINSPECTION TYPE: 3CLT MLG W/W O/B AFT 3RD VERTICAL STIFFENER FROM FWD IS CRACKED. REMOVED AND REPLACED CRACKED LT MLG W/W O/B AFT 3RD VERTICAL STIFFENER FROM FWD IAW MD-11 SRM 51-35-01. (MINOR)SDR FDEA202102040287Longeron · corrodedWHILE ACCOMPLISHING SPECIAL / NONROUTINE MAINTENANCE FORM # N01252 AFT CARGO COMPARTMENT RIGHT HAND STATION 1951 LONGERON 40 RIGHT FOUND CORRODED. AFT CARGO COMPARTMENT RIGHT HAND STATION 1946 TO STATION 2007 LONGERON 40 RIGHT RIGHT AREA REPAIRED AS PER SRMSDR FDEA202102030279Doubler · corrodedCTR CARGO COMPT, AT STA 1781 DOUBLER AFA7169-25 IS CORRODED. BLENDED CORRSION ON DOUBLER AT STA 1781 PN AFA7169-25 WITHIN LIMITS, REMOVED .005 REF SRM 51-21-01, SRM 53-00-00-2R-0 FIG 205SDR IPXA2021020465311Actuator · inoperativeL1 ENTRY DOOR ACTUATOR INOP. DEFERRED L1 ENTRY DOOR ACTUATOR IAW MEL 52 10 1 2 0 1 DMP 52 10 1 2 0 1 CW PLACARDS INSTALLED CONTROL M 734022T/S L1 DOOR PER FIM 52-11-810-802. R/R'D FWD DOOR LOCK PIN RELEASE RELAY. (R2-5324) PER WDM 52-11-01. RAN L1 DOOR SEVESDR IPXA2021020465324Door · unknownINSPECTION TYPE:NAL1 DOOR WILL NOT CLOSEL1 DOOR OP CHK GOOD IAW AMM 52-10-01SDR FDEA202102030282Doubler · corrodedCTR CARGO COMPT, AT STA 1781 DOUBLER AFA7169-23 IS CORRODED. 0005108155. REMOVED AND REPLACED DOUBLER AFA7169-23 STA 1781 REF DRAWING AFA 7169, SRM 51-33- 01SDR FDEA202102030281Doubler · corrodedCTR CARGO COMPT, AT STA 1781 DOUBLER AFA7169-9 IS CORRODED. 0005108155 : SHERWIN, REMOVED AND REPLACED DOUBLER AFA7169-9 STA 1781 REF DRAWING AFA 7169, SRM 51-33- 01SDR FDEA202102030280Doubler · corrodedCTR CARGO COMPT, AT STA 1781 DOUBLER AFA7169-19 IS CORRODED. REMOVED AND REPLACED DOUBLER AFA7169-19 STA 1781 REF DRAWING AFA 7169, SRM 51-33- 01SDR 9WGA2021020354301Indicator · activatedEXCESSIVELY HIGH TEMPERATURE INDICATIONS IN LOWER CENTER CARGO IN FLIGHT, 72 DEGREES C.SDR 9WGA2021020341101Unknown · vibrationAIR TURN BACK DUE TO SEVERE AIRFRAME VIBRATION AFTER GEAR RETRACTION.SDR FDEA202102020292Floor Support · corrodedCTR CARGO - FLOOR SUPPORT CHANNEL CORRODED AT STA 1781 (MRKD). REMOVED AND REPLACED CORRODED FLOOR SUPPORT AFA8359-19 PER SRM 51-31-01-0G.SDR IPXA2021020265235Indicator · inoperativeINSPECTION TYPE:NA**DIVERSION - EMERGENCY DECLARED WITH ATC-ARFF ADVISED OF HAZMAT INFO- AC LANDED W/OUT INCIDENT** DURING CLIMBOUT, CAPT'S PFD SHOWED CHK POS AND CAPT'S ATTITUDE INDICATOR HEADING AND VERTICAL SPEED WERE 180 OUT. FO HAD AMBER ATT ON FO'S PFD.SDR IPXA2021020165186Cable · out of rigINSPECTION TYPE:NAWHILE WORKING ON L1 CABIN DOOR FOUND AFT UPPER CABLE AND LOWER CABLE OUT OF RIGRIGGED L1 DOOR CABLES PER AMM 52 11 02 830 801 PARA F. STEP (10) PERFORMED F/W PASSENGER DOOR OPERATION TEST PER AMM 52 11 02. OPS CHECK GOOD DOOR OK TO CONTINUE FSDR FDEA202101280215Longeron · corrodedFORWARD CARGO COMPARTMENT - STATION 1119 TO STATION 6-10, LONGERON 45 LEFT FOUND WITH CORROSION. CORRODED LONGERON AT FORWARD CARGO COMPARTMENT BETWEEN STATION 1119 TO STATION 6-10, LONGERON 45 LEFT REPAIRED AS PER SRM 53-00-05-2R REPAIR 1 FIGURE 202 BY SDR FDEA202101280276Cargo Track · corrodedLOWER CENTER CARGO COMPARTMENT FLOOR RAIL AT STA 1681 BL ZERO BOTTOM SIDE OF RAIL CORRODED 0005108584 : CRUZ, TOMAS G - 03-FEB-2021 01:18 REMOVED CORRODED BRACKET PN A5A7086-13 AND REPLACED WITH NEW BRACKET PN A5A7086-13 REF SRM 51-33-01-0G.SDR FDEA202101280216Floorbeam · crackedCENTER CARGO COMPARTMENT - FLOORBEAM AT STATION 1741, BETWEEN X=-6.5 AND X= 6.5 FOUND CRACK. REPAIR CARRIED OUT ON CRACK FLOOR BEAM AT CENTER CARGO COMPARTMENT STATION 1741, BETWEEN X=-6.5 AND X= 6.5 AS PER EA NUMBER 1-5321-T0359449 PART 1 TITLE: FUSELAGSDR IPXA2021012965038Battery · dischargedEMERGENCY LT BAT LOW LIGHT DURING PREFLIGHT. OK TO CONTINUE PER MEL 33-50-4 DMP COMPLIED WITH. PLACARD INSTALLED.REPLACED EMERGENCY LIGHTING BATTERY POWER SUPPLY PER AMM 33-51-01-401. TEST GOOD, M734125 CLEARED. DMP REVERSED. IPC 33-51-01-05-015SDR IPXA2021012965045Battery · failedL1 ESCAPE SLIDE BOTTLE PRESS INDICATION LIGHT FAILURE. DEFERRED PER MEL/DMP 25-61-2.T/S PER FIM 25-61-02. R/R'D BATTERIES. OPS CHK GOOD REF MM 25-61-04-400-801. REMOVED PLACARD DMI LOG. M734086 CLEARED.SDR FDEA202101270200Hinge · wornUPPER CARGO DOOR, FOUND FUSELAGE SIDE HINGE NUMBER 2 PART NUMBER ACA 7223-511 WITH 15 LOBES WORN. WORN 15 LOBES AT UPPER CARGO DOOR, FUSELAGE SIDE HINGE NUMBER 2 PART NUMBER ACA 7223-511 REWORKED AND FOUND NUMBER 14 AND NUMBER 15 COUNTING FROM FORWARD EXSDR FDEA202101260195Floor Panel · gougedMAIN CABIN FLOOR, PANEL 282CS, HOLES IN UPPER FACE SHEET OF FLOOR BOARD. REPAIRED MAIN CABIN FLOOR PANEL 282CS P/N AEA0183-54 HOLES IN UPPER SURFACE FACE, AS REQUIRED REF SRM 53-00-50-2R.SDR IPXA2021012764983Switch · inoperativeINSPECTION TYPE: N/A LI DOOR SWITCH NOT WORKING DOOR WILL NOT OPEN/CLOSE ELECTRICALLY. MANUALLY CLOSED DOOR THEN OPERATED DOOR WITH SWITCH. OPEN/CLOSE OPERATIONS CHECK GOOD, IAW AMM 52-11-02 .SDR IPXA2021012664891Unknown · fumesINSPECTION TYPE: NA ATB-EMERGENCY DECLARED-LANDING UNEVENTFUL-O2 MASKS USED-NO OTHER EQUIP USED. A/C WAS TAKEN OUT OF SERVICE. SHORTLY AFTER TAKEOFF ALL 3 CREW SMELLED FUMES LIKE SOMETHING WAS BURNING. COULD NOT DISCOVER SOURCE FUMES REMAINED FOR ENTIRE FLISDR FDEA202101250244Floor Panel · delaminatedMAIN CABIN, LT APPROX STA 1361 PANEL 261KF IS DELAMINATED AND HAS SEVERAL PUNCTURES. MAIN CABIN LT APPROX STA 1361 FABRICATED NEW PANEL 261KF PER DWG SRZ-25-005.SDR FDEA202101250239Floor Panel · damagedMAIN CABIN, LT APPROX. STA 1361 PANEL 261KF IS DELAMINATED AND HAS SEVERAL PUNCTURES. MAIN CABIN LT APPROX STA 1361 FABRICATED NEW PANEL 261KF PER DWG SRZ-25-005.SDR IPXA2021012564839Roller · lack of lubeL1 DOOR DOES NOT CLOSE/SEAL COMPLETELY ON FORWARD SIDE. THE DOOR DOES NOT OPERATE SMOOTHLY DURING THE LAST HALF OF THE CLOSING EITHER. ITEM DEFERRED PER MEL 52-10-3-1-2-1 PLACARD INSTALLED. DI# M733638 ASSIGNED. AIRCRAFT OK TO CONT. CRV.CLEANED AND LUBED TRACKSDR IPXA2021012564846Skin · damagedINSPECTION TYPE: N/A DEFLECTION AND CRACK ON THE LOWER EDGE OF THE BULK CARGO DOOR DOUBLER REPAIR, IAW EO MD11-5230-78942-B.
Back to Boeing MD-11F