Boeing MD-90-30
Service difficulty reports · 6,066
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD9030' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD9030' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DLM90100542Wire · brokenCABIN EMERGENCY PATH LIGHTS INOP. SPLICED BROKEN WIRES LIGHTS TEST GOOD.SDR DALA1319279211Mount · corrodedENGINE AFT MOUNT SUPPORT FITTING FASTENERS CORRODED. REPAIRED IAW 02-469466-12 ME01 AND ME02.SDR DLM90100466Wire · brokenCABIN FLOOR EMERGENCY ESCAPE PATH LIGHTS INOP FROM SEAT 10 TO 12. FOUND BROKEN WIRE AT SEAT 10. REPAIRED WIRE REF SWPM CH 20, LIGHTS CK OK.SDR DLM90100429Wire · damagedEMERGENCY EXIT IDENTIFIERS AT L2 AFT CABIN DOORS INOP. REMOVED BATTERY PACK IN O/H AT ROW 38CDE. REINSTALLED BATTERY PACK IN O/H AT ROW 38CDE. REPAIRED WIRING AT QUICK DISCONNECT AT L2 DOOR. FOUND PIN PUSHED BACK AT Q/D FOR AFT CABIN DOOR LIGHT. REINSTALLEDSDR DLM90100512Coalescer Bag · dirtyCABIN EXUDES STRONG EXHAUST FUMES REPORTED BY INBOUND CREW. CHECKED RECIRC FAN AND FILTER ALL OK REPLACED LT AND RT WATER BAGS LEAK CHECKS OK RAN PACKS NO ODOR.SDR DLM90100432Battery Pack · inoperativeAFT CABIN EMERGENCY FLOOR LIGHTS NOT WORKING PROPERLY. REPLACED AFT CABIN BATTERY PACK AND BATTERY POWER SUPPLY. OPS GOOD.SDR DLM90100240Strut · dischargedRED NOSE POSITION LIGHT REMAINED ILLUMINATED AFTER T/O RETRACTION. PERFORMED NLG STRUT EXT CHECK, FOUND X DIMENSION BELOW LIMITS. SERVICED NOSE STRUT TO PROPER LIMITS. JACKED ACFT NOSE RETRACTED NOSE GEAR SEVERAL TIMES. OPS OK. RETURNED ACFT SDR DLM90100146Slide · inoperativeDURING A PLANNED 2L DOOR SLIDE DEPLOYMENT IAW OP 6800 THE SLIDE DID NOT INFLATE. THIS OCCURRED ON 1-20-10. THE SLIDE PACK WAS ATTACHED TO THE FLOOR FITTINGS AND EXITED THE DOOR CAVITY BUT MERELY HANGED OUTSIDE THE ACFT WITHOUT INFLATING. THE OP 6800 DATA RETRISDR DLM90100113Bulb · inoperativeEMERGENCY ESCAPE PATH LIGHT. ONE BULB INOP. REPAIRED WIRE AND RELAMPED - OPS OK - MCO/PLAC RMVD.SDR DLM90092034Generator · leakingBOTH ENG GENERATORS FAILED IN FLIGHT. INSPECTED RT GEN FOUND LEAKING 514447206. REMOVED REPLACED RT ENG GENERATOR IAW AMM. INSPECTED LT GEN FOUND LEAKING 574447206. REMOVED & REPLACED LT ENGINE GENERATOR IAW AMM.SDR DLM90092020Frame · dentedACFT ENCOUNTERED A BIRD STRIKE ON THE FUSELAGE JUST ABOVE THE F/O EYEBROW WINDOW AT THE FS 148 FRAME BETWEEN L-6R AND L-8R. THE SKIN WAS REPAIRED ON ERA 478136-14 AND THE FRAME HAS BEEN REPAIRED ON ERA 478189-14.SDR DLM90092021Link Assy · wornRETURN AIR TURN-AROUND FOR HEAVY VIBRATION UNDER COCKPIT AFTER GEAR RETRACTION. GEAR LEVER SELECTED TO DOWN VIBRATION STOPPED. FOUND LT NOSE GEAR DOOR OPEN ON TAXI IN 952847. SUSPECT LT FWD NOSE GEAR DOOR LINK FAILED. REPLACED LT FWD DOOR LINK. JACKED ACFSDR DLM90091965Seal · damagedON T/O ROLL AUTOSPOILER FAIL MESSAGE ILLUMINATED. WHEN GEAR WAS RETRACTED THE GEAR HANDLE ONLY CAME HALFWAY UP AND ALL 3 GEAR LIGHTS WENT RED. THE GEAR HANDLE WAS RETURNED TO THE DOWN POSITION AND ALL 3 GEAR LIGHTS TURNED GREEN. THE OAP SHOWED LT & RT EEC SDR DLM90091964Valve · malfunctionedON TAKEOFF NOSEGEAR DID NOT RETRACT. GREEN LIGHT WENT OUT AND RED LIGHT REMAINED ON. FOLLOWED QRH ,GEAR EXTENDED WITH NORMAL DOWN AND LOCKED INDICATIONS. FOUND NOSE LANDING GEAR STRUT DEFLATED AT GATE NO EVIDENCE OF STRUT FLUID LEAKAGE REMOVED AND REPLACED SDR DALA1318909210Skin · damagedMAINTENANCE FOUND DAMAGE ON THE FUSELAGE SKIN FS 219 L17L. REPAIRED IAW ERA 470347-14 REV B.SDR DLM90091915Relay · shortedAFTER BLOCK IN IRS NR 1 BATTERY FAIL LIGHT ILLUMIN W/ ASSOCIATED CAUTION MSG APU DID NOT ST AND BATTERY VOLT READ 10 VOLTS ALSO NOTED ACRID ELECTRICAL ODOR IN COCKPIT AND FIRST CLASS CABIN. REPLACED BATTERY CHARGER BATTERY CHARGER RELAY R2-56 AND 3 SHIPS BATTSDR DLM90091866Door · out of rigAFTER RAISING LANDING GEAR ON T/O EXPERIENCED VERY LOUD VIBRATION IN NOSE AREA. SLOWED DOWN PUT GEAR DOWN AND NOISE DECREASED MAX SPEED 200 KTS VIBRATION VBS. STILL BAD AT 160 KTS. RIGGED NOSE DOORS PER M/M. CYCLED GEAR SEVERAL TIMES, ALL INDICATIONS NORMASDR DALA1317549208Skin · dentedMX FOUND A DENT AT THE FWD LAV DRAIN HOLE AT BS 271 AND BETWEEN L29-30R. REPAIR IAW ERA 477270-14.SDR DLM90091534Skin · crackedFUSELAGE SKIN CRACKED AT FS 1475 BETWEEN LONGERON 1R AND 2R.SDR DLM90091476Skin · corrodedCORROSION ON FUSELAGE SKIN AT FS 826 LONGERON 29 AND 30 RT. REPAIRED PER ER/A 476999-14 REV 0.SDR DLM90091424Handset · shortedIN CRUISE FWD F/A PANEL HANDSET CORD BECAME VERY HOT, SMOKED AND MELTED. PULLED C/B'S A10 AND A8 IAW MX CORD COOLED. FOUND FWD F/A HANDSET CORD SHORTED. REPLACED HANDSET. OPS NORMAL.SDR DLM90091356Skin · damagedMAJOR REPAIR COMPLETED PER ERA 470350-14 REV B 8/18/09. LOCATED FUSELAGE STA 218 STR 18L.SDR DLM90091299Flap · dentedRE-INSPECTION OF THE DENT FOUND ANOTHER DENT, ON 08/01/09. NO EMERGENCY PROCEDURE REQUIRE, WILL NEED A SRM/ERA REPAIR. UNKNOWN ON WHAT CAUSE THE DENTS. A PERMANENT REPAIR DONE AT ATL.SDR DLM90091290Skin · dentedDURING LO WALK AROUND FOUND A DENT ON TOP A ERA 462536-14 REPAIR DOUBLER. INFORMED MCC AND ENGINEERING. C/W VISUAL INSP PER ERA 476064-14. NO CRACKS OR PULLED FASTENERS NOTED. C/W S/M REPAIR PER PRI 476094-14 REV 0, 1, 2, 3, 4. ALSO ERA 476094-14 REV A FASDR DLM90091212Engine · dirtyDESCENT AT 15000 TO LEVEL OFF POWER INCREASE GOT STATUS MSG LT STATOR VANE FAIL THEN CREW NOTIFICATION OF LOUD POPPING NOISES ON LEFT AFT SIDE, THEN LEFT ENGINE RPM DECREASED TO 35 PCT N1 AND EGT NEAR 600C. OIL PRESS AT 85 PSI. SHUTDOWN WAS 620C NO OTHER ABNSDR DLM90091208Actuator · malfunctionedDESCENT AT 15000 FT TO LEVEL OFF POWER INCREASE GOT STATUS MSG "L" STATOR VANE FAIL. THEN CREW NOTIFICATION OF LOAD POPPING NOISES ON LEFT AFT SIDE, THE LEFT ENGINE RPM DECREASED TO ~35% N1 AND EGT NEAR 600C. OIL PRESS AT 85 PSI. SHUT DOWN ENGINE AS EGT STASDR DLM90091086Connector · damagedL ENGINE GENERATOR OVERHEAT MESSAGE APPEARED IN FLIGHT THEN EXTINGNISHED. FOUND OIL COOLING LINE LEAKING AND GENERATOR FAILED.REPLACED OIL COOLING LINE AND GENERATOR. CONNECTORS DAMAGED. WILL NEED HARNESS ASSY MFG P/N 290W5211-509 DPN 242710080. DUE TO HASDR 2009FA0000697Connector · brokenCONNECTOR BROKEN OFF GENERATOR. UNIT RUBS WHEN ROTATED. CAUSE OF FAILURE WAS DUE TO ADE BEARING FAILURE. ROOT CAUSE WAS UNDETERMINED. (K)SDR DALA1154639232Skin · crackedAFT FUSELAGE RT SIDE STA CANT 1554-1567 REPAIRED IAW BOEING REPAIR SKETCH 200906050006-0003 (DE 1029120).SDR DLM90090991Monitor · overheatedVIDEO UNIT OVER 25A AND 25B OVERHEATED AND STARTED SMOKING. FLT ATTENDANTS REMOVED POWER FROM UNIT AND SMOKE AND BURNING SMELL WENT AWAY. UNIT COOLED DOWN. INSPECTION FOUND SOURCE OF SMOKE TO BE AT OVHD MONITOR AT 25 A/B. REMOVED AND CAPPED CONNECTOR TO MOSDR DLM90090840Control Unit · failedELEVATOR SPLIT MESSAGE ON EOAP FOR LOSS OF LEFT ENG GENERATOR. TROUBLESHOT PER MD-90 TSM 27-30 PAGE 5. DUE TO LEFT GENERATOR POWER FAULT SUSPECT ACS SYSTEM LOST LEFT ELEVATOR POSITION INDICATION CAUSING FAULT. CLEARED ELEVATOR SPLIT MESSAGE THROUGH MCDU. SDR DLM90090820Skin · dentedACCOMPLISHED PERMANENT REPAIR PER ERA 469965-14 REV C LOCATED FWD OF FS 229 ABOVE S-18L. INSTALLED STRAPS TO EXISTING SKIN REPAIRS TO COMBINE WITH ADJACENT REPAIR INSTALLED BY ERA 466737-14.SDR DALA1317499208Skin · crackedRIGHT STABILIZER UPPER SKIN INBD FOUND CRACKED 1.2500" LONG. REPAIR IAW 02-460214-12 ME06.SDR DALA1317489208Skin · crackedLEFT STABILIZER UPPER SKIN WAS CRACKED 1.2500" LENGTH INBD AFT END. REPAIR IAW 02-460214-12 ME05 (02-460214-12).SDR DLM90090640Housing · failedAIRCRAFT LOST BOTH HYDRAULIC SYSTEM AFTER LANDING. FOUND LT MANUAL REVERSION CYLINDER HOUSING HAD FAILED. FOUR EACH BOLTS THAT SECURE THE TOP OF THE CYLINDER TO THE HOUSING HAD SHEARED CAUSING CYLINDER TO SEPARATE. FOUND LEFT ELEVATOR MANUAL REVERSION CYLISDR DALA1207799236Skin · damagedREPAIR SKIN AT STA 168.750 STR 26-27RT IS WRINKLED IAW SG09530002 AND BOEING MESSAGE NR 1-1253793814 AND TECHNICAL ORDER PAM-TO-51-02.SDR DALA1301659205Skin · damagedMX FOUND A DENT AND GOUGE AT BS 588, L27R, DAMAGED AREA IS ROUGHLY 25 INCHES LONG AND CROSSES OVER A BUTT SPLICE, BS 568. REPAIRED IAW ERA 473851-14. (ERA 473851-14)SDR DLM90090330Fastener · looseENGINE AFT MOUNT SUPPORT FITTING FASTENER INSPECTION PER EA 02-469466-12AD. UPPER AFT FASTENER (AFT FASTENER ON ROW A) FAILED INSPECTION. REPLACED ALL 8 FASTENERS IN FITTING PER EA INSTRUCTIONS. REPLACEMENT OF DISCREPANT FASTENERS CONSTITUTES A MAJOR REPAIR SDR DALA1134579221Skin · crackedCRACKS ON THE NR 1 ENGINE INLET COWL LIP SKIN (S/N 0216001).SDR DLM90081735Spar · dentedRT HORZ STAB UPPER SKIN AND REAR SPAR UPPER CHORD FLANGE COMMON TO XFS 165 HAD AN EDGE DENT AND GOUGE. THE DAMAGE WAS TRIMMED OUT, TREATED AND PAINTED.SDR DLM90081702Boot · wornLEVELING AT 33000 ALT FLOW LIGHT ILLUMINATED RT PACK FLOW DROPPED TO ZERO DESCENDED TO 24000 RAN QRH PROCEDURES FOR FLOW LIGHT AND LOSS OF PACK DID NOT RESTORE PRESSURIZATION CABIN ALT REACHED 13500 DESCENDED TO 10000 ALT CABIN DOOR LIGHT ILLUM OUT OF 24000.SDR DLM90081435Engine · bird ingestionHIT BIRD AT ABOUT 135 KTS. HIGH SPEED ABORT ACCOMPLISHED AND PARKED WITH HOT BRAKES. RT ENGINE FLUCTUATED AND HAD NOTICABLE POWER LOSS WITH THE BIRD STRIKE. BRAKE TEMP REACHED 650. REPLACED NR 2 ENGINE.SDR DLM90081247Slide · malfunctionedINADVERTANT DEPLOYMENT OF TAIL CONE FROM EXTERNAL HANDLE, SLIDE DID NOT DEPLOY. RE-INSTALLED TAIL CONE PER AMM. TAIL CONE DISPLACEMENT SYS NITROGEN CYLINDER ALSO SERVICED PER AMM. COMPLIED WITH RII REQUIREMENT FOR TAIL CONE INSTALLATION/SAFETY/SECURITY AND SDR DALA1315349207Door Frame · corrodedFUSELAGE FORWARD CARGO DOOR LOWER FRAME, REPAIRED IAW ERA 470229-14, ERA 470229-14.SDR DLM90081118Ballast · inoperativeBURNING ODOR AFT CABIN NEAR ROW 39 CDE. FOUND 2 EA SIDEWALL LIGHTS INOP AND INOP BALLAST BAD AFT OF O/H BAG BIB 39 CDE. REPLACED BALLEST AND LIGHTS OPS GOOD.SDR DALA1302819201Skin · corrodedCORROSION ON THE FUSELAGE SKIN BETWEEN BS 826-845 AT THE ATTACH POINT FOR THE LOWER WTB FAIRING. REPAIRED IAW ERA 470201-14.SDR DLM90081116Skin · corrodedDURING CURRENT HMV, DAMAGE (CORROSION) WAS FOUND ON FUSELAGE SKIN AT WING TO BODY FAIRING. REPAIR WAS ACCOMPLISHED PER SRM 53-04 FIGURE 53. MANUFACTURER APPROVED USE OF SUBJECT SRM ON 9215 PROVIDED THERE WERE NO DEVIATIONS. ADDRESSED ON ERA 470199-14.SDR 2008FA0000575Shaft · seizedGENERATOR UNIT SEIZED. THE GENERATOR FAILURE ROOT CAUSE WAS DETERMINED TO BE A ROTOR BAND SHAFT WHICH RESULTED IN AN OUT OF BALANCE CONDITION. THE OUT OF BALANCE ROOT CAUSED AN EARLY FAILURE OF THE ADE BEARING. ALL OTHER DAMAGE RESULTED FROM THE BEARING FAILURSDR 2008FA0000551Bearing · seizedPUMP SEIZED, OIL PUMP BEARING BRACKET SHOWED SIGNS OF RUBBING WITH THE OIL PUMP GEAR. PENDING ENGINEERING EVALUATION. (K)SDR DLM90081103Fitting · corrodedFOUND FITTING CORRODED. REPLACED FITTING REF SRM`S 51-30-02, 51-30-05, 53-10-01, & 53-10-02D.
Back to Boeing MD-90-30