Douglas DC-8-62
Service difficulty reports · 2,778
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC862' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC862' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA001656Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1140, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED MISDRILLED HOLES, FABRICATED SDR RRXA0001653Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1200, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED EXISTING DISCREPANT HOLES, FABSDR RRXA000921Skin · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE R-2 DOOR IN THE LOWER INNER SKIN CENTER OF DOOR BOTTOM, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR DOUBLER FROM 7075-T6 AND INSSDR RRXA001520Attach Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOORBEAM ATTACH FITTING UPPER CHORD (MAIN CABIN) AT STA 717 AND RBL -23 Z AXIS 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM . REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FITTISDR RRXA001516Attach Fitting · misdrilledDURING A MAINTENANCE VISIT FOUND A DRILLED HOLE IN THE FUSELAGE. STRUCTURE FLOORBEAM ATTACH FITTING AT UPPER LEG IN RADIUS OF STA 702 LBL +23, AXIS 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND SDR RRXA000815Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1460, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES WITH AD RIVET MATERIAL, FABSDR RRXA000728Panel · delaminatedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LT WING TRAILING EDGE LOWER PANEL AFT OF DUMP CHUTE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED T/E PANEL IAW DC-8 SRM 51-3-0 ANSDR RRXA001674Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1020, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES, FABRICATED DOUBLERS ASDR RRXA001670Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1360, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATESDR RRXA001667Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1240, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED ALL DISCREPANT HOLES, FABRICSDR RRXA001658Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT ST 1100, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED ALL EXISTING HOLES, FABRICATESDR RRXA001655Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1160, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED ALL DISCREPANT HOLES, FABRICSDR RRXA001649Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1280, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED EXISTING DISCREPANT HOLES, FASDR RRXA000996Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOOR BEAM AT STA 980, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED DOUBLER FROM 7075-T6 ANDSDR RRXA001513Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE RT FLOORBEAM UPPER LOWER CARGO BAY FS 360, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR ANGLE FROM 7075-T6 AND INSTALLED IASDR RRXA000812Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILL HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED EXISTING HOLES USING AD RIVET MATERSDR RRXA001652Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1220, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED EXISTING DISCREPANT HOLES, FASDR RRXA000941Structure · crackedDURING A MAINTENANCE VISIT, FOUND 5 CRACKS TO THE BULKHEAD THRU DOOR AT THE AFT LOWER CARGO BILGE AT STA 1380, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW BULKHEAD DOOR IAW DSDR RRXA000729Panel · delaminatedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LT WING TRAILING EDGE LOWER PANEL AFT OF FUEL DUMP CHUTE HINGED DOOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW WING T/E PASDR RRXA000957Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT TOP OF FLOORBEAM AT STA 620, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED ALL EXISITING HOLES, FABRICASDR RRXA001665Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1040, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED SDR RRXA000963Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 420, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED ALL DISCREPANT HOLES, FABRISDR RRXA000960Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 480, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICASDR RRXA001528Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES IN THE CABIN FLOOR AT STA 834 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED DOUBLER FROM SDR RRXA000731Panel · delaminatedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LT WING TRAILING EDGE UPPER PANEL I/B OF I/B AILERON, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW WING T/E PANEL IAW DC-8 SRMSDR RRXA000730Panel · delaminatedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LT WING AUX SPAR LOWER PANEL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW LT WING LWR AUX APR IAW DC-8 SRM 51-3-0 AND 51-1-21SDR RRXA001699Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE AND POSSIBLE CRACK ON THE ATTACH FITTING AT STA 940 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW ATTACH FITTING AND INSTALLED IAW DC-SDR RRXA001519Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES IN THE CABIN FLOORBEAM AT STA 822 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED DOUBLER FRSDR RRXA000818Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT UPPER CARGO COMPT TOP OF FLOORBEAM AT STA 1420, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED STSDR RRXA001529Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE CABIN FLOORBEAM AT STA 742 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED DOUBLERS WITSDR RRXA000873Spar Cap · gougedDURING A MAINTENANCE VISIT FOUND A GOUGE AT THE SCREW HOLE ON THE LT WING I/B L/E LWR FRONT SPAR CAP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. BLENDED DRILL START SMOOTH AND RETURNED TO SERVICE PSDR RRXA000862Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE IN THE LT WHEEL WELL AT STA 940 AND LONGERON 24 LT. ON LONGERON 24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED FITTING IAW DC-8 SRM 5SDR RRXA000858Shim · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT. WING I/B NR 1 PYLON WING SPAR LWR CHORD SHIM PLATE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED SHIM FROM 7075-T6 AND INSTALLED IAW E.O. #99-236 WSDR RRXA000857Shim · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT. WING I/B NR 4 PYLON WING SPAR LWR CHORD SHIM PLATE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED SHIM FROM 7075-T6 AND INSTALLED IAW DCSDR RRXA000961Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 460, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. PLUGGED EXISITING HOLES, FABRICATED DOUBLERS FRSDR RRXA001524Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES IN THE CABIN FLOORBEAM AT STA 717 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED DOUBLER FSDR RRXA001522Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE CABIN FLOOR BEAM AT STA 781 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED DOUBLER FROMSDR RRXA000867Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE VERTICAL STIFFNER AT STA 188 AND RBL 69 Z AXIS -10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED PLATE & SHIM FROM 2024-T3 AND INSTASDR RRXA002327Attach Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE WEB ATTACH FITTING AT FS 1400 AND L21R FRAME TO PRESS, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-20D, 5SDR RRXA000944Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES TO THE TOP OF FLOORBEAM IN THE FWD. UPPER CARGO COMPT. AT STA 360, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLESSDR RRXA000923Attach Fitting · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK TO THE FLOORBEAM ATTACH FITTING AT STA 759 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW ATTACH FITTING IAW DC-8 SRM, 51-3-0 AND 51-1-20SDR RRXA001515Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED FITTING AT THE PRODUCTION BREAK AT STA 680 - 700 AND LONG 11 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW ATTACH FITTING IAW DC-8 SRM 51SDR RRXA002394Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING O/B LEADING EDGE O/B SEGMENT UPPER RIB AT STA XFS 760.000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8SDR RRXA002393Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING O/B LEADING EDGE O/B SEGMENT UPPER RIB AT STA XFS 772.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8SDR RRXA002392Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING O/B LEADING EDGE O/B SEGMENT UPPER RIB AT STA XFS 822.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8SDR RRXA002391Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING O/B LEADING EDGE O/B SEGMENT UPPER RIB AT STA XFS 828.750, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8SDR RRXA002390Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT O/B LEADING EDGE O/B SEGMENT UPPER RIB AT STA XFS 847.500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM SDR RRXA001698Frame · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK IN THE WHEEL WELL FRAME OUTBD. SIDE NEAR OPENING FOR GEAR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACK, FABRICATED DOUBLER FROM 2024-SDR RRXA001697Pressure Panel · distortedDURING A MAINTENANCE VISIT, FOUND DISTORTED SKIN IN THE RT WHEEL WELL AT FWD AND AFT SIDE OF RT MLG OPENING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED ANGLE FROM 2024-T3 AND INSTALLSDR RRXA001686Skin · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE AROUND THE SCREW HOLES ON THE LT WING CENTER LE UPPER SURFACE AT XFS 325 TO XFS 304, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED DOUB
Back to Douglas DC-8-62