Douglas DC-8-73F
Service difficulty reports · 15,471
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA10874Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE BATHTUB FITTING AT STA 300 BETWEEN L34R TO L35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. RECEIVED PART AND INSTALLED IAAW DC-8 SRM 53-2-0, FIG 2B.SDR DHL2001806510Floor Support · crackedC-CHECK: FWD.CARGO BAY. FLOOR SUPPORT ANGLE CRACKED 1 INCH AT STA.480 L-31 TO L-32 RT. PREFORMED STOP HOLE,FABRICATED DOUBLER AND INSTALLED IAW. SRM 53-02-0 FIG 1B. STATUS-CLOSED.SDR RRXA11047Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FITTING AT STA 1230 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20D. (CORRSDR RRXA11045Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON FITTIND AT STA 1150 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20SDR RRXA11030Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FITTING AT STA 1180 AND L36L-L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-1-0, 51-SDR DHL2001806572Floor Support · crackedC-CHECK - MAIN CARGO FLOOR SUPPORT ANGLE CRACKED 1/2 INCH AND DEFORMED BL.0 AT STA 8.000. REMOVED CRACKED FLOOR SUPPORT ANGLE AND FABRICATED FLOOR SUPPORT ANGLE. IAW SRM 53-2-0 PAGE 2E/2F. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED FLOOR SUPPOSDR DHL2001806560Rib · crackedC-CHECK - LT WING LE RIB UPPER PART 1 INCH CRACK AT STA XFS 860. PERFORMED STOP DRILL AND FABRICATED DOUBLER IAW SRM 57-2-0 FIG 2. CLEANED, TREATED & PRIMED IAW SRM 51-1-8B PAGES 1-12, 13. INSTALLED DOUBLER IAW SRM 57-2-0 FIG 2. STATUS-CLOSED.SDR DHL2001806552Angle · crackedC-CHECK - MAIN CARGO FLOOR SUPPORT ANGLE CRACKED 1/2 INCH AND DEFORM BL 0 AT STA 8.000. REMOVED CRACKED FLOOR SUPPORT ANGLE AND FABRICATED FLOOR SUPPORT ANGLE IAW SRM 53-2-0 PAGE 2E/2F. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED FLOOR SUPPORT SDR DHL2001806531Rib · crackedC-CHECK - RT WING INBOARD FLAP INTERIOR SKIN RIB SHOWS CRACKS AT STA XRS 162.263. STOP DRILLED IAW SRM 57-2-0 FIG 2. FABRICATED DOUBLER IAW SRM 57-2-0 FIG 2. TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED DOUBLER IAW SRM 57-2-0 FIG 2. STATUS-CLOSED.SDR UPS01835324Battery · dischargedINSPECTION TYPE LOWER CARGO COMPARTMENT FIRE DETECTOR SN FA2392 HAS LOW BATTERY FAULT. SMOKE DECTOR REMOVED AND REPLACED BATTERIES AT DETECTOR FA2392. FOUND D BATTERY LEVELS LOW. REPLACED BATTERIES, LOWER CARGO SMOKE DETECTOR SYSTEM OPS CKS NORMAL, DSDR DHL2001806599Skin · delaminatedC-CHECK - RT WING FLAP JOINT DELAMINATED. R/R JOINT FLAP IAW MM 57-20-1 PAGE 204-214. STATUS-CLOSED.SDR DHL2001806589Frame · damagedC-CHECK - MAIN CARGO COMPARTMENT - FRAME DEFORMED STA 1580.000 L-20 LT. REMOVED FASTENERS IAW SRM 51-1-20D PAGE 21. REMOVED DAMAGED FRAME IAW SRM 53-20 PAGE 25 THRU 27. FABRICATED NEW FRAME IAW SRM 53-2-0 PAGE 25 THROUGH 27. PERFORMED THERMAL TREATMENT TO SDR DHL2001806584Web · crackedC-CHECK - MAIN CARGO COMPARTMENT SUBFLOOR SHOWS 02 EA CRACKS 1/4 INCH. RBL 52 STA 55.000. PERFORMED STOP HOLE IAW SRM 53-2-0 FIG 1B. FABRICATED DOUBLER IAW SRM 53-2-0 FIG 1B. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. AND INSTALLED DOUBLER IAW SRM 53-2-0 FSDR DHL2001806571Web · crackedC-CHECK - MAIN CARGO SUBFLOOR SHOWS 02 EA CRACKS 3/8 AND 5/8 RBL 8 1/2 STA 25.000. PERFORMED STOP HOLE AND FABRICATED DOUBLER IAW SRM 53-2-0 FIG 1B. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B AND INSTALLED DOUBLER IAW SRM 53-2-0 FIG 1B. STATUS-CLOSED.SDR DHL2001806554Web · crackedC-CHECK - MAIN CARGO COMPARTMENT SUB-FLOOR SHOWS 02 EA CRACKS 1/4 INCH RBL 52 STA 55.000. PERFORMED STOP HOLE IAW 53-2-0 FIG 1B. FABRICATED DOUBLER IAW SRM 53-2-0 FIG 1B. CLEANED, TREATED & PRIMED IAW SRM 51-1-8B. INSTALLED DOUBLER IAW SRM 53-2-0 FIG 1B. SDR DHL2001806553Web · crackedC-CHECK - MAIN CARGO SUB-FLOOR SHOWS 02 EA CRACKS 3/8 AND 5/8 RBL 8 1/2 INCHES STA 25.000. PERFORMED STOP HOLE AND FABRICATED DOUBLER IAW SRM 53-2-0 FIG 1B. CLEANED, TREATED, AND PRIMED IAW SRM 51-1-8B AND INSTALLED DOUBLER IAW SRM 53-2-0 FIG 1B. STATUS-CSDR DHL2001806551Web · crackedC-CHECK - MAIN CARGO SUB-FLOOR AT STA 8.000 RBL 46 CRACKED 3 1/4 INCHES. PERFORMED STOP HOLE AND FABRICATED DOUBLER IAW SRM 53-1-0 FIG 1B. CLEANED, TREATED & PRIMED IAW SRM 51-1-8B. INSTALLED DOUBLER IAW SRM 53-2-0 FIG. 1B. STATUS-CLOSED.SDR DHL2001806546Intercostal · crackedC-CHECK - MAIN CARGO AFT BULKHEAD INTERCOASTAL DOUBLER CRACKED 1 INCH AT STA 1760.00 L-6R. STOP DRILLED IAW SRM 53-2-0 FIG 18. FABRICATED DOUBLER IAW SRM 53-2-0 FIG 1B. TREATED, PRIMED IAW SRM 51-1-8B AND INSTALLED DOUBLER IAW SRM 53-2-0 FIG 1B. STATUS-CSDR DHL2001806521Angle · crackedC-CHECK - FWD. CARGO BAY TRANSVERSAL ANGLE CRACKED 1/2 INCH AT STA 260 L-33RT. PERFORMED STOP HOLE, FABRICATED DOUBLER IAW SRM 53-2-0 FIG 1B. CLEANED, TREATED, AND PRIMED IAW SRM 51-1-8B AND INSTALLED DOUBLER IAW SRM 53-2-0 FIG 1B. STATUS-CLOSED.SDR DHL2001806516Floor Support · brokenFWD CARGO COMPARTMENT SHOWS FLOOR SUPPORT BROKEN BETWEEN STA 120-180, L34L. REMOVED BROKEN FLOOR SUPPORTING ANGLE BETWEEN STA 120.00 AND STA 180.00, L-34L.IAW SRM 51-1-21. FABRICATED NEW FLOOR SUPPORTING ANGLE IAW SRM 53-2-0 FIG 1B. CLEANED, TREATED, AND PSDR UPS01835298Frame · crackedINSPECTION TYPE: PREFLT. PREVIOUS REPAIR BENT AND CRACKED AT STA 1580 LT 2 INCHES ABOVE FLOOR (FUSELAGE FRAME.) SUPPLEMENTAL: REMOVED DAMAGED REPAIR FABRICATED REPAIR DOUBLER AND INSTALLED DOUBLER PER E.O. DC8 5310 13993SDR RRXA11041Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO SEAT TRACK AT STA 590 AND RBL 60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3FIG8A, 51-3-0. (CORROSION DAMAGESDR DHL2001806583Web · crackedC-CHECK - MAIN CARGO COMPARTMENT SUBFLOOR CRACKED 1 3/4 INCH RBL 20, STA 55.000. STOP DRILLED IAW SRM 53-2-3 PAGE 39-40. FABRICATED DOUBLER IAW SRM 53-2-3 PAGE 39-40. TREATED AND PRIMED IAW SRM 51-1-8B. AND INSTALLED DOUBLER IAW SRM 53-2-3 PAGE 39-40. STSDR DHL2001806534Floor Support · crackedC-CHECK - FWD. CARGO COMPT. FLOOR SUPPORT ANGLE CRACKED 2 INCH AT STA 580. L-34 LT. PERFORMED STOP HOLE. FABRICATED DOUBLER AND INSTALLED IAW SRM 53-2-0 FIG 1B. STATUS-CLOSED.SDR DHL2001806522Floor Support · crackedC-CHECK - FWD. CARGO COMPARTMENT - FLOOR SUPPORT ANGLE CRACKED 2 INCHES AT STA 200 L-35RT. PERFORMED STOP HOLE, FABRICATED DOUBLER AND INSTALLED IAW SRM 53-2-0 FIG 1B. STATUS-CLOSED.SDR DHL2001806512Fitting · crackedFWD. CARGO COMPARTMENT - FITTING CRACKED 3 INCH BETWEEN STA. 440.000 AND STA. 460.000. L-31L REMOVED CRACKED FITTING FROM FWD CARGO COMPT. STA. 440-460 L-31L IAW SRM 51-1-20D PAGE 21 CLEANED, TREATED, AND PRIMED IAW SRM 51-1-8 PAGE 12-15 INSTALLED NEW FITTINSDR RRXA11043Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO ALL 6 T-BOLT FITTINGS AT STA 1160-1220 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SSDR RRXA11042Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO RH VERT STAB SKATE ANGLE AT STA 1766-1780 AND L2R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.FABRICATED PART AND INSTALLED IAW DC-SDR DHL2001806550Floor Panel · crackedC-CHECK - MAIN CARGO D FLOOR AT STA 887.000 CRACKED 2 INCHES. CUTOUT DAMAGED AREA OF FLOOR PANEL D AT STA 887 AND FABRICATED FILLER AND DOUBLER IAW SRM 53-2-3 PAGE 39-40. CLEANED, TREATED & PRIMED IAW SRM 51-1-8B, PAGES 1,12&13. INSTALLED FILLER AND DOUBLSDR DHL2001806593Fitting · crackedMAIN CARGO BAY SPLICE FITTING CRACKED 2 INCH AT STA 900 - 920 L-1. REMOVED CRACKED SPLICE FITTING AT STA 900 - 920 L-1 IAW SRM 51-1-200 PAGE 21. CLEANED, TREATED & PRIMED IAW SRM 51-1-8B. INSTALLED NEW FITTING IAW SRM 51-1-20D PAGE 9. STATUS-CLOSED.SDR DHL2001806585Cargo Track · crackedC-CHECK - MAIN CARGO NR 3 TRACK SHOWS A BREAK OF 2 INCHES AND POINTS OF CORROSION BETWEEN STA 640.000 - STA 718.000. REMOVED DAMAGED AREA OF FLOOR TRACK 3 RT AND FABRICATED SPLICE IAW SRM 53-2-3 PAGE 49-50. FABRICATED TRACK IAW SRM 53-2-3 PAGE 49-50. CLEASDR DHL2001806785Cargo Track · brokenC-CHECK - MAIN CARGO NR 3 TRACK SHOWS A BREAK OF 2 INCH AND POINTS OF CORROSION BETWEEN STA 640.000 - STA 718.000. REMOVED DAMAGED AREA OF FLOOR TRACK 3 RT AND FABRICATED SPLICE IAW SRM 53-2-3 PAGE 49-50. FABRICATED TRACK IAW SRM 53-2-3 PAGE 49-50. CLEANED, SDR DHL2001706550Floor Support · crackedC-CHECK - MAIN CARGO D FLOOR AT STA 887.000 CRACKED 2 INCHES. CUTOUT DAMAGED AREA OF FLOOR PANEL D AT STA 887 AND FABRICATED FILLER AND DOUBLER IAW SRM 53-2-3 PAGE 39-40. CLEANED, TREATED & PRIMED IAW SRM 51-1-8B, PAGES 1,12&13. INSTALLED FILLER AND DOUBSDR DHL2001806548Angle · crackedC-CHECK - MAIN CARGO COMPT FLOOR E COUPLING ANGLE CRACKED 1 INCH STA 720.00. REMOVED ANGLE DETERIORATED IAW SRM 51-3-0. FABRICATED ANGLE IAW SRM 53-2-0 FIG 1B. CLEANED, TREATED, AND PRIMED IAW SRM 51-1-8B. INSTALLED ANGLE IAW SRM 53-2-0 FIG 1B. STATUS-CLSDR DHL2001806524Floor Support · crackedC-CHECK - FWD CARGO COMPARTMENT - FLOOR SUPPORT ANGLE CRACKED 1/2 INCH AT STA 360.000 L-33R. PERFORMED STOP HOLE IAW SRM 53-2-0 FIG 1B. FABRICATED DOUBLER AND INSTALLED IAW SRM 53-2-0 FIG 1B. STATUS-CLOSED.SDR DHL2001806517Fairing · brokenC-CHECK - LT WING TE LOWER FAIRING BROKEN 1 INCH AT XW 106.000. PERFORMED STOP HOLE AND FABRICATED DOUBLER IAW SRM 57-2-0 PAGE 1B. CLEANED, TREATED, AND PRIMED IAW SRM 51-1-0 PAGE 12-13. INSTALLED DOUBLER IAW SRM 57-2-0 FIG 1B. STATUS-CLOSED.SDR DHL2001806513Fitting · crackedFWD CARGO COMPARTMENT - FITTING CRACKED 6 INCHES BETWEEN STA 600.000 AND STA 620.000. L-31R. REMOVED CRACKED FITTING (FWD CARGO COMPT STA 600-620, L-31R) IAW SRM 51-1-20D PAGE 21. CLEANED, TREATED, AND PRIMED AREA IAW SRM 51-1-8 PAGE 12-13. INSTALLED FITTISDR RRXA11044Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO C-PIT DOOR LWR #6 LATCH BACK UP FITTING AT STA Y=1210, X=24R, Z=-30, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND SDR DHL2001806598Seat Track · crackedC-CHECK - MAIN CARGO COMPT. SEAT TRACK 1 LH LUGS BROKEN (STA 504 - 512). CUT OUT DAMAGED AREA OF SEAT TRACK (STA 504-512) AND FABRICATED SPLICE IAW SRM 53-2-3 PAGE 49-50 FABRICATED TRACK (P/N 52772660) IAW SRM 53-2-3 PAGE 49-50. CLEANED, TREATED AND PRIMED SDR RRXA010020Fire Loop · malfunctionedSHORTLY AFTER DEPARTURE FROM IAH, EB127/796FT AIR RETURNED TO IAH DUE TO NR 4 FIRE WARNING. REPLACED O/B LOOP ASSY ON LOWER FAN CASE, ADJUSTED WIRE BUNDLES NEXT TO START VALVE DUCT. RAN ENGINE NO MALFUNCTION FOUND. DID BLEED AIR LEAK CHECK. NO LEAK NOTED. SDR UPS01835285Smoke Detector · failedINSPECTION TYPE:PFLT PIT 31 SMOKE DETECTOR FAILED AT DEPARTURE. REPLACED BATTERIES IN PIT 31 SMOKE DETECTOR FA3450 IAW MM 26-18-02. THIS CLEARS M211233, PLACARD REMOVED.SDR RRXA11050Latch · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO A-PIT DOOR FRAME LWR NR 1 LATCH AT STA Y=285, X=24R, Z=-30, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-20D,SDR RRXA11049Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO A-PIT DOOR FITTING AT STA Y=350, X=24R, Z=-30, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRMSDR RRXA11048Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BATHTUB FITTING AT STA 300 AND L33R-L34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1SDR RRXA11038Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO SKIN DOUBLER AT STA 70-80 AND L31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DWG#5649028. (CORSDR RRXA11037Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO ANTENNA PAD AT STA 87-93 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-11, 51-3-0.SDR RRXA11036Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO ANTENNA MOUNT PLATE AND SKIN AT STA 367-373, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-3-01.SDR RRXA11035Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BULGING SKIN AT STA 180-190 AND L31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21SDR RRXA11034Doubler · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FINGER DOUBLER AT STA 180-200 AND L31R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-0 1F, 51-1-21, 51-1-20D.SDR DHL2001806592Floor Support · brokenC-CHECK - MAIN CARGO FLOOR SUPPORT ANGLE AT STA 8.000 RBL 46 BROKEN. STOP DRILLED IAW SRM 53-2-0 FIG 1B. FABRICATED REINFORCING ANGLE.
Back to Douglas DC-8-73F