Douglas DC-9-32
Service difficulty reports · 12,755
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC932' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC932' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MWEA99653Beam · gougedAFT CARGO DOOR TOP BEAM WEB IS GOUGED. MAINTENANCE INSTALLED REPLACEMENT WEB.SDR MWEA99652Bracket · misdrilledAFT CARGO DOOR NR 5 BEAM FROM TOP HAS MISDRILLED HOLE THROUGH AFT END. MAINTENANCE PLUGGED HOLE AND FABRICATED AND INSTALLED NEW BRACKET.SDR MWEA99651Support · corrodedFLOOR BOARD SUPPORT AT FUSELAGE STATION 200 HAS CORROSION ON SEAT TRACKS. MAINTENANCE FABRICATED AND INSTALLED NEW SUPPORT.SDR MWEA99650Support · crackedCENTER LINE FLOOR SUPPORT HAS NUMEROUS CRACKS ON UNDERSIDE OF BEND RADIOUS. MAINTENANCE FABRICATED AND INSTALLED NEW FLOOR SUPPORT.SDR MWEA99649Floor · crackedSUBFLOOR IS CRACKED AT RIVET HOLE AT STATION 205. MAINTENANCE FABRICATED AND INSTALLED NEW FLOOR DOUBLER.SDR MWEA99648Floor · crackedSUBFLOOR CRACKED AT STATION 210 AT NUT PLATE. MAINTENANCE FABRICATED AND INSTALLED DOUBLER.SDR MWEA99647Outer Pan · misinstalledAFT CARGO DOOR OUTER PAN HAS NUMEROUS NUT PLATES IN PLACE OF FASTENERS. MAINTENANCE REMOVED AND REPLACED DOOR OUTER PAN.SDR MWEA99646Bulkhead Web · crackedAFT PRESSURE BULKHEAD WEB IS CRACKED AT VENTRAL DOOR JAMB. MAINTENCANCE REMOVED AND INSTALLED NEW DOOR WEB.SDR MWEA99643Laynard · detachedGALLEY DOOR SLIDE COVER MISSING ATTATCHING PIN AT BOTTOM. REINSTALLED EVAC SLIDE LANYARD.SDR AT9900753Balance Wt · corrodedFOUND RIGHT ELEVATOR BALANCE WEIGHT WAS CORRODED. REMOVED AND REPLACED RIGHT ELEVATOR BALANCE WEIGHT IAW DC9 SRM 55-01 PG 3, 51-30-1.SDR AT9900739Skin · dentedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND DENT THAT WAS FORMED FROM INSIDE. FABRICATED REPAIR DOUBLER AND FILLER IAW RES NR 07421, DC9 SRM 53-04 FIG 1, 51-10-04, AND 51-10-03.SDR MWEA99665Cover · detachedGALLEY DOOR EMERGENCY SLIDE COVER AND GIRT BAR CABLE CAME OFF WHEN SERVICING GALLEY IN DCA. MAINTENANCE REATTACHED EMERGENCY DOOR GIRT BAR AND SIDE.SDR MWEA99642Slide · detachedTHE GALLEY DOOR E. MAINTENANCE REATTACHED EMERGENCY DOOR GIRT BAR.SDR AT9900735Frame · crackedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CRACK IN CANTED FRAME AT BS 1143R. CUT AND REMOVED CANTED FRAME AT BS 1143R IAW EO 99-1285.SDR AT9900733Sub-Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, CORROSION WAS FOUND IN THE SUB FLOOR AT 160-200. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC9 SRM 51-30-02, 51-30-08, AND 53-01 FIG 2.SDR AT9900694Support · corrodedFOUND IN CABIN FORWARD SECTION AT RIGHT FLOOR SUPPORT 10 FROM SERVICE DOOR WAS CORRODED, BS 160-200. REMOVED CORRODED FLOOR SUPPORT, FABRICATED AND INSTALLED REPAIR SUPPORT IAW DC9 SRM 51-10-2, 51-10-4, 51-10-3, 53-01 FIGURE 1, 51-30-5.SDR MWEA99644Striker · defectiveRIGHT MAIN GEAR (RED) UNSAFE LIGHT STAYS ILLUMINATED WITH GEAR RETRACTE. REPLACED MAIN GEAR UPLATCH MECHANISM AND STRIKER ASSEMBLY.SDR AT9900750Floor · corrodedFOUND RT INBOARD FLOOR PANEL AT BS 579-617 CORRODED. FLOOR PANEL HAT SECTION CORRODED ON SQUARE ENDS AND ANGLED ENDS. MOST OF THE FASTENER HOLES ON THE TOP OF THE FLOOR PANEL HAVE CORROSION AND CIRCULAR WEAR GROOVES. REMOVED CORROSION FROM AROUND FASTENER SDR AT9900704Bulb · failedFOUND BOTH TAIL CONE SLIDE EMERGENCY LIGHTS WILL NOT ILLUMINATE. REPLACED LAMPS IAW DC9 MM 33-50.SDR AT9900714Window Frame · corrodedFOUND UPPER CORNER OF WINDOW FRAME WAS CRACKED AT BS 699R. REMOVED WINDOW FRAME, INSTALLED NEW WINDOW FRAME IAW DC9 SRM 51-30-5, 53-04 FIGURE 34.SDR ABXA9900726Batteries · dischargedEMERGANCY LIGHTS WOULD NOT TEST. REPLACED POWER SUPPLY BATTERIES.SDR TWAA9917414Frame · crackedDURING OP 16 MAINT CHECK AT STA 83 FORMER CRACKED AT LBL 10. STOP DRILLED CRACK. HFEC STOP DRILL PER TWA NDT PART 6-51-00-03, CRACK CONTAINED. REPAIRED CRACK PER SRM 53-03, FIG 34.SDR TWAA9917413Frame · crackedDURING OP 16 MAINT CHECK AT STA 83 FORMER WAS CRACKED AT RBL 10. STOP DRILLED CRACK AND HIGH FREQ EDDY CURRENT STOP DRILL PER NDT PART 6. CRACK CONTAINED PER 51-00-03. CRACK REPAIRED PER SRM 53-03, FIG 34.SDR TWAA9917406Angle · crackedDURING OP 16 MAINT CHECK, FOUND T ANGLE CRACKED, FORWARD SIDE OF STA 63, RBL 13. REMOVED AND REPLACED PART PER TWA STANDARD PROCESSES MANUAL 6-70-01.SDR TWAA9917405Angle · crackedDURING OP 16 MAINT CHECK, FOUND ANGLE CRACKED, AFT SIDE OF STA 69, LBL 13. REMOVED AND REPLACED PART PER TWA STANDARD PRACTICES MANUAL 6-70-01.SDR MWEA99624Longeron · crackedLONGERON 3R AND 4R IS CRACKED AT STATION 756. MAINTENANCE FABRICATED AND INSTALLED REPAIR SPLICE.SDR AT9900796Doubler · corrodedFOUND MILLED DOUBLERS CORRODED BEYOND LIMITS AT BS 340 LONGERON 30. REMOVED AND REPLACED WITH NEW DOUBLERS IAW DC9 SRM 51-10-3, 51-30-1, 51-30-2.SDR AT9900746Angel · corrodedFOUND CAP L ANGEL CORRODED AND CRACKED 4AT BS 965-BL24R. REMOVED CAP ANGEL AND REPLACED, FABRICATED AND INSTALLED 8 TRACKED ANGLE REPAIR IAW TIMCO RES 07186 AND DC9 SRM 53-30-5.SDR AT9900706Angle · corrodedFOUND AFT AIRSTAIR, FIFTH STEP FROM THE BOTTOM AT SUPPORT ANGLE, WAS CORRODED. REMOVED CORRODED ANGLE, FABRICATED, TREADED, PRIMED, AND INSTALLED NEW ATTACH ANGLE IAW DC9 SRM 51-10-1, 52-60-0, 51-10-3, 51-10-5, 51-30-2, 51-30-5.SDR AT9900688Angle · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY, FL, FOUND SUPPORT ANGLE FOR AFT VENTRAL STAIRS AND 3RD STEP CORRODED. REMOVED, FABRICATED, AND INSTALLED SUPPORT ANGLE ON AFT STAIRS AND NR 3 STEP IAW DC9 SRM 51-10-3, 51-30-2, 51-30-5.SDR AT0000188Channel · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOOR PANEL RIGHT INBOARD HAT SECTION AT BS 579 - 617 CORRODED. FOUND OUT OF LIMITS AFTER CORROSION REMOVAL. INSTALLED NEW HAT SECTIONS IAW DC9 SRM 53-01, 51-10-04, AND 53-21.SDR AT9900708Support · corrodedFOUND FLOOR SUPPORT AT BS 200-218 WAS CORRODED, ABOUT 14 FROM CENTER LINE. REMOVED FLOOR SUPPORT, FABRICATED, TREATED, PRIMED AND INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 51-10-2, 51-10-4, 51-30-1.SDR AT9900707Step · corrodedFOUND AFT AIRSTAIR NR 3 WAS CORRODED. REMOVED AND REPLACED STEP IAW DC9 SRM 51-10-3, 53-01, 53-30-1.SDR AT9900692Support · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY, FL, FOUND FLOOR SUPPORT AT LBL 50 BS 160-200 WAS CORRODED. REMOVED, FABRICATED, AND INSTALLED FLOOR SUPPORT IAW DC9 SRM 51-10-3, 51-30-2, 53-11-1.SDR AT9900690Suport · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY, FL, FOUND FLOOR SUPPORT CORRODED AT BS 205, RBL 0-40. REMOVED, FABRICATED, AND INSTALLED FLOOR SUPPORT IAW DC9 SRM 51-10-3, 51-10-4, 51-30-5.SDR GTIA9901145Wire · failedMYR - ONE EMERGENCY 'WHITE' FLOOR TRACK LIGHTING INOPERATIVE IN TAILCONE. FOUND WIRES BAD AT DIGITAL. REMOVED AND REPLACED AS NEEDED. OPS CHECK GOOD. (M)SDR ATT9900673Switch · failedSHUTDOWN NR 2 ENGINE IN FLIGHT DUE TO OIL QUANTITY LOSS. FOUND OIL PRESSURE SWITCH DISINTEGRATED.SDR AT9900752Support · corrodedFOUND CABIN FLOOR SUPPORT BS 200 BL 0-BL 42L WAS CORRODED BEYOND LIMITS. REMOVED CORRODED SECTION OF FLOOR SUPPORT, FABRICATED AND INSTALLED REPAIR FLOOR SUPPORT IAW DC9 SRM 53-11-1, 51-10-3, 51-10-4, 51-30-5.SDR AT9900673R1Switch · malfunctionedSHUT DOWN NR 2 ENGINE IN FLIGHT DUE TO OIL QUANTITY LOSS. FOUND OIL PRESSURE SWITCH DISINTEGRATED. REMOVED AND REPLACED OIL PRESSURE DIFFERENTIAL SWITCH AND LOW OIL PRESSURE SWITCH IAW MM 79-32.SDR ABXA9900732Splice · crackedDURING C-CHECK, FOUND FLOORBEAM TO FRAME SPLICE PLATE CRACKED STATION 718 LEFT SIDE. REPLACE SPLICE PLATE IAW DC9 SRM.SDR ABXA9900731Pan · crackedDURING C-CHECK, FOUND FORWARD LOWER CARGO DOOR PAN CRACKED AT NR 5 BEAM AT THE FORWARD UPPER CORNER AND THE FORWARD LOWER CORNER. REPAIRED DOOR PAN IAW DC9 SRM 52-03.SDR ABXA9900729Intercostal · crackedDURING C-CHECK, FOUND INTERCOSTAL CRACKED BETWEEN STATION 200 AND 207 AT LONGERON 11 RIGHT. REPAIRED INTERCOSTAL IAW DC9 SRM DWG 05159.SDR AT9900734Frame · crackedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, BS 737 MAINFRAME LEFT SIDE HAS THREE CRACKS. REMOVED AND REPLACED LEFT MAINFRAME BS 737 IAW DC9 EO 12-5311-29-B1044.SDR 9904449923Frame · crackedDURING MAINTENANCE INSPECTION, NOSE LANDING GEAR JAMB BEAM AT FS 47 WAS FOUND CRACKED AT BOTH LEFT AND RIGHT DOOR JAMBS. REPAIRED PER EA 99-169112.SDR TWAA9913201Conductor · wornTHE FWD SECTION OF COACH FLOOR EGRESS LIGHTING WAS INOPERATIVE IN TEST. REPLACED THE CONDUCTOR STRIP FROM THE BATTERY TO THE LIGHT STRIP. CHECK-C 3-26-99 MCI.SDR MWEA99623Panel · chafedVERTICAL STABILIZER CANOE PANEL WAS CHAFED AT AFT END FROM HORIZONTAL STABILIZER FAIRINGS ON LEFT AND RIGHT SIDE. MTC FABRICATED AND INSTALLED REPLACEMENT PANEL.SDR MWEA99622Skin · chafedVERTICAL STABILIZER WAS CHAFED AT AFT END FROM HORIZONTAL STABILIZER FAIRINGS ON RIGHT SIDE. MTC FABRICATED AND INSTALLED NEW SKIN AND ANGLE.SDR MWEA99621Frame · crackedFRAME WAS CRACKED AT STATION 120. MTC FABRICATED AND INSTALLED REPAIR ANGLES.SDR MWEA99620Skin · dentedTWO DENTS ON SKIN AFT OF STATION 945 BELOW LONGERON 25R. MTC FABRICATED AND INSTALLED DOUBLER REPAIR.SDR MWEA99619Skin · chafedVERTICAL STABILIZER IS CHAFED AT AFT END. MTC FABRICATED AND INSTALLED NEW SKIN AND ANGLE.
Back to Douglas DC-9-32