Douglas DC-9-83
Service difficulty reports · 16,530
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC983' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR TWAA9902103Skin · crackedVERTICAL STABILIZER UPPER L/E HAD 5 BY 3 BY 0.400 INCH DEEP DENT AND 3 INCH CRACK. REPAIRED PER SPM 55-03, PAGE 5, CLASS B REPAIR. CHECK-C 4-10-98 STL.SDR TWAA9901901Light · inopFOUND FLOOR EGRESS LIGHTS INOPERATIVE FROM CABIN ROW 11 AFT. FOUND WIRE DISCONNECTED AND RECONNECTED SAME. CHECK-C 12-8-98 MCI.SDR ASAA9980031Wire · disconnectedPDX - FLT 583 - CREW REPORTED EMERGENCY EXIT FLOOR TRACK LIGHTS IN FIRST CLASS WERE INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9980032Batteries · dischargedSEA - DURING MAINTENANCE CHECK, THE FORWARD OVERWING EMERGENCY EXIT IDENTIFIERS WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND OPERATED NORMALLY. (M)SDR TWAA9901906Casting · crackedDURING OP 16 MAINT CHECK, THE FWD AIRSTAIRS FORWARD DOOR CASTING WAS CRACKED IN RADIUS APPROXIMATELY 1.5 INCH LONG. REMOVED AND REPLACED CASTING PER STANDARD PROCESSES MANUAL 6-70-01.SDR TWAA9901905Skin · delaminatedDURING OP 16 MAINT CHECK, FOUND RUDDER DELAMINATED ON RT SIDE AT AFT SIDE OF CENTER HINGE. REPAIRED PER SRM 51-90-0, PAGE 49, AND 51-70-1A PAGE 21.SDR TWAA9901707Fitting · corrodedDURING OP 16 MAINT CHECK, FOUND FLOOR FITTING CORRODED AT STA 1193 AT CUSP LINE, RT SIDE OF AFT CARGO BIN. REMOVED LIGHT SURFACE CORROSION USING RUBBER BACK SANDING DISC AND ALUMINUM OXIDE DISC, PER SPM 6-80-01. REINSTALLED ORIGINAL BOLTS AND NUTS IN FITTINGSDR TWAA9901501Battery Pack · dischargedCABIN EGRESS LIGHTS WERE INOPERATIVE FROM ROWS 11 TO 21. REINSERTED WIRES IN EGRESS TRACK LIGHTING AND REPLACED THE BATTERY PACK. CHECK-C 12-8-98 MCI.SDR TWAA9901708Seat Track · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION IN CHAIR TRACK AT STA 1099, 44 IN LBL. REMOVED CORROSION PER TWA SPM 6-80-01. INSTALLED NEW TRACK PER SRM 53-05, FIG 4F.SDR TWAA9901502Light · inopFOUND EGRESS LIGHTS INOPERATIVE AT FORWARD GALLEY AND AT ROWS 4, 5, 17, 22, 26, AND 33. REPLACED LIGHT MODULES, MFG 0105606-002 AND 0105606-003. CHECK-C 10-25-98 STL.SDR ORJA9922Battery Pack · dischargedSJC - EMERGENCY LIGHTS ON SEAT 11 THROUGH 14 ARE INOPERATIVE. REMOVED AND REPLACED FORWARD RIGHT EMERGENCY EXIT BATTERY PACK, OPS CHECK GOOD. (M)SDR TWAA9901706Frame · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION AT STA 1219 APPROXIMATELY RBL 4 IN UNDERNEATH UPPER PART OF FORMER RING. REMOVED CORROSION PER SRM 6-80-01, PG 1 TO 3. REINSTALLED FORMER FOOT, AFTER CLEANING CORROSION, PER SPM 6-70-01, PG 3 AND USED AD FASTENERS.SDR TWAA9901705Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND FLOORBEAM CAP CORRODED AT STA 1156 BETWEEN TRACK LBL 22 AND LBL 42. FABRICATED NEW PART FROM 7075 T6. INSTALLED PER TWA STD PROCESSES MANUAL 6-70-01.SDR TWAA9901704Web · corrodedDURING OP 16 MAINT CHECK, FOUND IN CABIN, WEB CRACKED AND CORRODED AT STA 1156 UNDER FLOOR. REMOVED CORROSION PER SRM 51-10-3, PARA 31 TO 42. REPAIRED WEB PER 53-01, PG 9 FIG 2 SHEET 3.SDR TWAA9901710Angle · corrodedDURING CHECK-C MAINT, FOUND DOOR JAM AT FUSELAGE STA 1155 ATTACH ANGLE WAS CORRODED, AFT CARGO COMPT. REMOVED ANGLE AND INSTALLED NEW ANGLE PER DOUGLAS PRINT 5930483.SDR TWAA9901709Angle · corrodedDURING CHECK-C MAINT, FOUND AFT CARGO BIN DOOR JAM ATTACH ANGLE WITH CORROSION AT STA RW 1203, INTERIOR STRUCTURE OF DOOR JAM LIP. REMOVED ANGLE AND INSTALLED NEW ANGLE PER DOUGLAS PRINT 5930483.SDR ORJA9917Batery Pack · dischargedLAX - SECTIONS 12-16 SHIP RIGHT EMERGENCY EVAC LIGHTS FLICKER ON. REMOVED AND REPLACED BATTERY PACK. OPS CHECK OK. (X)SDR TWAA9901703Membrane · crackedDURING OP 16 MAINT CHECK, FOUND FLOOR MEMBRANE REPAIR DOUBLER CRACKED IN 2 PLACES AT STA 1271 TO 1307. REMOVED OLD DOUBLER AND INSTALLED NEW ONE PER SRM 53-05, PG 347 TO 351. USED AD FASTENERS PER SRM 6-30-07 PAGE 1 AND 2.SDR TWAA9901702Membrane · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOOR MEMBRANE AT STA 927 TO 946, 58.8 LBL. REMOVED 9 INCH BY 13 IN FLOOR MEMBRANE AND INSTALLED NEW 2024-T3 0.040 DOUBLER EXTENDING TWO FASTENER ROWS BEYOND CUT LINE PER SRM 53-01, FIG H, SHEET 3.SDR TWAA9901605Angle · corrodedDURING OP 16 MAINT CHECK, FOUND AFT CARGO COMPT FLOOR SUPPORT ANGLE ON TOP OF FORMER STA 1212 RBL CORRODED. REMOVED AND REINSTALLED ANGLE PER TWA STD PROCESSES 6-70-01.SDR TWAA9901604Membrane · corrodedDURING OP 16 MAINT CHECK, THE CABIN FLOOR MEMBRANE WAS CORRODED AT STA 743 RT SIDE. REMOVED CORROSION PER STANDARD PROCEDURES MANUAL 6-80-01. FABRICATED AND INSTALLED DOUBLER PER SPM 6-70-01, PG 1.SDR ASAA9980026Slide · failed testOAK - DURING C-CHECK, THE R1 DOOR EMERGENCY EVACUATION SLIDE FAILED THE EMERGENCY LIGHT AMP TEST. REPLACED THE R1 DOOR EMERGENCY EVACUATION SLIDE ASSEMBLY. (M)SDR ASAA9980025Batteries · dischargedPDX - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE CATWALK AREA WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND OPERTED NORMALLY. (M)SDR ASAA9980024Power Supply · inoperativePDX - DURING MAINTENANCE CHECK, THE EXTERIOR OVERWING EMERGENCY LIGHTS WERE FOUND INOPERATIVE. REPLACED THE POWER SUPPLY AND OPERATED NORMALLY. (M)SDR TWAA9901606Seat Track · corrodedDURNG OP 16 MAINT CHECK, FOUND IN CABIN, CORROSION IN CHAIR TRACK AT RBL 44 IN, STA 237, 262 TO 264, AND STA 275. REPLACED TRACK RBL 44 FROM STA 237 TO 275 PER SRM 53-005, PG 10G.SDR TWAA9901602Angle · crackedDURING OP 16 MAINT CHECK, FOUND FUSELAGE TO VERTICAL STABILIZER TIE ANGLE CRACKED APPROX 1.5 INCH LONG AT STA 1426 BETWEEN LONGERON 1L AND 2L, INSIDE LOWER STABILIZER. REPLACED ANGLE PART NR 5912188-35 PER STANDARD PROCESSES MANUAL 6-70-01.SDR TWAA9901105Retract Mech · iced upTHE LANDING GEAR HANDLE WAS DIFFICULT TO MOVE TO THE DOWN POSITION. REQUIRED TWO HANDS AND SOME FORCE. MAINTENANCE PERFORMED NORMAL AND EMERGENCY GEAR EXTENSION AND FOUND NORMAL. CHECKED CABLE RUNS IN ELECTRONIC COMPT AND FOUND NORMAL. POSSIBLE ICE AFTER HESDR TWAA9901309Structure · corrodedDURING OP 16 MAINT CHECK, FOUND IN FWD LT CABIN DOOR WHERE SEAL CONTROL SHAFT PASSES THRU INTERNAL STRUCTURE TO CONNECT WITH SEAL ACTUATING LINK, STRUCTURE HAS CORROSION APPROXIMATELY 17 INCHES FROM LE OF DOOR AND 4 INCHES FROM BOTTOM OF DOOR. INSTALLED NEW SSDR TWAA9901307Membrane · corrodedDURING OP 16 MAINT CHECK, FOUND FLOOR MEMBRANE CORRODED AT STA 522 TO 541, RT SIDE. REMOVED CORROSION PER STD PROCESSES MANUAL 6-80-1, PARA B PG 1. REPAIRED PER SRM 53-01, PG 18.SDR TWAA9901306Membrane · corrodedDURING OP 16 MAINT CHECK, FOUND SIDEWALL FLOOR MEMBRANE WITH CORROSION BETWEEN LONGERON 655 AND 658. CUT OUT CORRODED AREA, INSTALLED 3 INCH BY 16 INCH 2024T3 0.032 DOUBLER, PER SRM 53-01, PG 18 FIG 4.SDR TWAA9901001Lamp · failedTHE EGRESS LIGHTS WERE INOPERATIVE AT CABIN ROWS 9, 22, 27, AND 28. REPLACED THE LAMP FOR EACH OF THE INOPERATIVE LIGHTS. CHECK-C 11-3-98 MCI.SDR AALA990069Light · defectiveDFW - DURING MAINTENANCE CHECK, EMERGENCY EXIT FLOOR PATH LIGHTS IN FIRST CLASS CABIN WERE INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP IN FIRST CLASS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR TWAA9901305Membrane · damagedDURING OP 16 MAINT CHECK, FOUND HOLE IN MEMBRANE AT STA 199, APPROXIMATELY LBL 16 INCHES. CUT OUT DAMAGE AND INSTALLED DOUBLER PER SRM 53-01, PAGE 18 FIG 4.SDR TWAA9901209Intercostal · corrodedDURING OP 16 MAINT CHECK, FOUND INTERCOSTAL FOOT CORRODED BETWEEN STA 1212 AND 1219, RBL 4 IN. INSTALLED NEW FOOT PER SRM 6-70-0 PG 3 AND USED FASTENERS PER SPM 6-30-01 PAGE 1 AND 2.SDR TWAA9901208Membrane · corrodedDURING OP 16 MAINT CHECK, FOUND FLOOR MEMBRANE CORRODED STA 465 TO 475 ON LT SIDE. CUT OUT CORRODED SECTION AND INSTALLED TWO ROW REPAIR DOUBLER PER SRM 53-01, PG 18.SDR TWAA9901207Membrane · corrodedDURING OP 16 MAINT CHECK, FOUND FLOOR MEMBRANE CORRODED AT STA 400 TO 408, LT SIDE. CUT OUT CORRODED SECTION AND INSTALLED TWO ROW REPAIR DOUBLER PER SRM 53-01, PG 18.SDR TWAA9901206Membrane · crackedDURING OP 16 MAINT CHECK, FOUND I/B EDGE OF MEMBRANE CRACKED BENEATH CHAIR TRACK AT STA 1063, LBL 42 IN. REPAIRED MEMBRANE PER SRM 53-01, PG 9.SDR TWAA9901205Membrane · corrodedDURING OP 16 MAINT CHECK, FOUND FLOOR MEMBRANE WITH CORROSION BETWEEN STA 598 AND 617 AT CABIN SIDEWALL AREA. CUT OUT DAMAGED AREAS AND INSTALLED DOUBLER PER SRM 53-01, FIG 2.SDR ORJA9910Battery Charger · dischargedIN RNO - EMERGENCY EXIT ROW LIGHTS AT SEAT 12, 13, 14, 15 CAME ON COULD NOT EXTINGUISH. REMOVED AND REPLACED BATTERY CHARGER AT SEAT 20A, SYSTEM OPS CHECK NORMAL AT THIS TIME. (M)SDR TWAA9901204Membrane · corrodedDURING OP 16 MAINT CHECK, FOUND FLOOR MEMBRANE CORROSION AT STA 484 TO 502 ON RT SIDE. REMOVED CORROSION PER SPM 6-80-01. REPAIRED PER SRM 53-01, PG 9.SDR TWAA9901203Seat Track · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION IN CHAIR TRACK AT STA 1206, LBL 22 IN. REPLACED CORRODED SECTION OF CHAIR TRACK PER SRM 53-05, PG 10G.SDR TWAA9901007Angle · corrodedDURING OP 15 MAINT CHECK, FOUND CORROSION ON AFT SIDE OF FORMER SUPPORT ANGLE, STA 1322 LONGERON 28R TO 27L. REMOVED CORROSION PER STRUCTURAL PROCEDURES MANUAL 6-70-1. CUTOUT AREA BEYOND LIMITS RBL 4 TO LBL 9. REPAIRED PER SRM 53-05, PAGE 6.SDR TWAA9900901Wire · brokenSEVERAL EGRESS LIGHTS WERE INOPERATIVE IN THE FWD CABIN. REPAIRED BROKEN WIRE AT THE END OF THE FIRST CLASS SECTION. CHECK-C 10-25-98 STL.SDR ORJA9916Door · not closedSEA - AT START OF TAKEOFF ROLL IN ANC, FORWARD CARGO DOOR LIGHT ILLUMINATED. DISCONTINUED TAKEOFF AT APPROXIMATELY TAXI SPEED. RETURNED TO TERMINAL AND HAD DOOR OPENED AND RECLOSED. LIGHT WENT OUT AND A/C PRESSURIZED MANUALLY. CONTINUED TO SEA IAW MD80 QRHSDR TWAA9901202Seat Track · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION IN CHAIR TRACK AT RBL 22 IN STA 237. REMOVED APPROX 60 INCHES OF SEAT TRACK STARTING AT STA 200. INSTALLED NEW TRACK AND SPLICE PER SRM 53-05, FIG 4F.SDR ASAA9980019Wire · disconnectedPDX - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE FOUND INOPERATIVE. RECONNECTED WIRING IN FLOOR TRACK AND OPERATED NORMALLY. (X)SDR TWAA9901201Rib · crackedDURING OP 16 MAINT CHECK, FOUND ON RT WING 2 CRACKS ON RIB LOCATED ONE FT O/B OF NR 8 TRACK. STOP DRILLED CRACKS AND INSTALLED DOUBLER PER SRM 57-01, FIG 3 SHEET 3.SDR ASAA9980017Wire · disconnectedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK RED LIGHTS IN THE AFT CABIN WERE FOUND INOPERATIVE. RECONNECTED WIRING IN FLOOR TRACK AND OPERATED NORMALLY. (X)SDR ASAA9980016Wire · disconnectedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE FOUD INOPERATIVE. RECONNECTED WIRING IN FLOOR TRACK AND OPERATED NORMALLY. (X)SDR ASAA9980014Wire · damagedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE FOUND INOPERATIVE. REPAIRED WIRING IN FLOOR TRACK AND OPERATED NORMALLY. (X)
Back to Douglas DC-9-83