SDR HNAA2021051900220Floor Support · corrodedLAV R/H FLOORBOARD SUPPORT HAS CORROSION AT POTABLE WATER ATTACH ELBOWS. REMOVED AND REPLACED LAV R/H FLOORBOARD SUPPORT IAW EMB 145 SRM 51-40-02.SDR HNAA2021051900219Floor Support · corrodedLAV L/H FLOORBOARD SUPPORT AT POTABLE WATER PULL HANDLE MOUNT HAS CORROSION. REMOVED AND REPLACED LAV L/H FLOORBOARD SUPPORT POTABLE WATER PULL HANDLE MOUNT IAW EMB 145 SRM 51-40-02.SDR HNAA2021051900218Floor Support · corrodedL/H #4 FLOORBOARD SUPPORT HAS CORROSION. REMOVED AND REPLACED L/H #4 FLOORBOARD SUPPORT IAW EMB 145 SRM51-20-03 AND SRM 51-40-02SDR HNAA2021051900217Floor Support · corrodedR/H #4 FLOORBOARD SUPPORT HAS CORROSION. REMOVED AND REPLACED RH #4 FLOORBOARD SUPPORT IAW EMB145 SRM 51--40-02.SDR HNAA2021051900216Floor Support · corrodedR/H #3 FLOORBOARD SUPPORT HAS CORROSION. REMOVED UNSERVICEABLE R/H #3 FLOORBOARD SUPPORT IAW EMB 145 SRM 51-40-02.POSITIONED, DRILLED AND INSTALLED SERVICEABLE R/H #3 FLOORBOARD SUPPORT IAW EMB 145 SRM 51-40-02 AND 51-20-03.SDR HNAA2021051900211Floorbeam · corrodedSSI 53-20-11 L/H FLOOR BEAM HAS CORROSION AT CROSS BEAM AT FRAME 54. REPAIRED LH CABIN OMEGA BEAM AFT OF FR 54 CROSS MEMBER IAW ETD2021-145-012775 AND EO1-53-21-0105SDR HNAA2021051900210Door Frame · failedFR 67 BROKE ABOVE CARGO DOOR CUTOUT. REPAIRED FRAME 67 ABOVE CARGO DOOR CUTOUT IAW PIEDMONT EO1-53-21-0109.SDR SIMA20210417005Skin · damagedCARGO DOOR EXTERIOR SKIN HAS A PREVIOUS BLEND (PAINTED OVER AND NOT ADDRESSED IN ADL) APPRX 12? FROM AFT EDGE, 24? FROM TOP-C/A-ACCOMPLISHED PERMANENT REPAIR OF CARGO DOOR EXTERNAL SKIN APPROX.. 12? FROM AFT EDGE AND 24? FROM TOP EDGE IAW EMB 145 SRM 52-30-01 SDR HNAA2021050400191Floor Support · corrodedRH OUTBD FLOOR SILL #2 IS PITTED .... REMOVED AND REPLACED NEW R/H OUTBOARD FLOOR SILL #2 TO IAW EMB 145 SRM 51-40-02SDR HNAA2021050400185Frame · corrodedCROSSBEAM AT FR 20 CORRODED ....REMOVED AND REPLACED SERVICEABLE CROSSBEAM AT FR 20 IAW EMB145 SRM 51-40-02 AND SRM 51-20-01SDR HNAA2021050400184Floor Support · corrodedRH CABIN #4 FLOOR SILL CORRODED. REMOVED AND REPLACED THE RH CABIN #4 FLOOR SILL IAW EMB 145 SRM 51-40-02SDR HNAA2021050400183Floor Support · corrodedLH CABIN #4 FLOOR SILL CORRODED .... REMOVED AND REPLACED NEW L/H CABIN #4 FLOOR SILL IAW EMB 145 SRM 51-40-02SDR HNAA2021050400172Floor Support · corrodedCARGO DOOR LOWER FLOOR SILL CORRODED .... REMOVED AND REPLACED NEW CARGO DOOR LOWER SILL IAW EMB-145 SRM 51-40-02SDR SIMA20210417002Flashlight Assy · inoperativeEMERGENCY FLASHLIGHT NEAR LAV WILL NOT CHARGE. DEFERED AFT EMERGENCY FLASHLIGHT PER MEL 25-32. AUTH # 040240M-C. M PROCEDURES COMPLIED WITH. R & R FLASHLIGHT ASSEMBLY BEHIND LAST ROW DOUBLE SEAT IAW AMM 33-50-16. OPS CHECK GOOD. MEL ITEM RESTORED. DEFERED AFSDR SIMA20210417001Lamp · inoperativePSU EMERGENCY LIGHT AT SEAT 12A INOP.-C/A-RAR OVERWING EMERGENCY LIGHT LAMP AT SEAT 12A IAW EMB145 AMM 33-50-07. OPC GOOD.SDR HNAA2021051900209Bumper · corrodedL/H EMERGENCY EXIT HAS CORROSION AT LOWER AFT BUMPER. REMOVED AND INSTALLED SERVICEABLE L/H EMERGENCY EXIT LOWER AFT BUMPER PROFILE "L" IAW EMB145 SRM 51-40-02.SDR HNAA2021051900208Web · chafedBAGGAGE DOOR INNER WEBBING FRAME HAS TWO CHAFE SPOTS. REPAIRED BAGGAGE DOOR INNER WEBBING FRAME CHAFES IAW PIEDMONT EO-1-52-21-0106.SDR SIMA20210416010Shear Tie · crackedCRACKED SHEAR CLIP AT FR 21 BETWEEN STR 1 RT AND STR 2 RT. -C/A-TRIMMED, DRILLED, AND INSTALLED SERVICEABLE FABRICATED SHEAR CLIP IAW SRM 51-40-02.SDR SIMA20210416009Firewall · crackedAPU FIREWALL HAS A CRACK PROTRUDING FROM THE UPPER R/H MOUNT-C/A-REPAIRED APU FIREWALL ON RH UPPER MOUNT IAW ETN-EM-53-244 R3.SDR SIMA20210416005Skin · crackedFUSELAGE SKIN HAS 4 EACH CRACKS AROUND RIVET (APPROX. 1/16" LONG) AT FRAME 79 BETWEEN STR 6R-7R. -C/A-REPAIRED SKIN AT FRAME 79 BETWEEN STR 6R-7R IAW SRM 53-32-01.SDR SIMA20210416008Skin · crackedFUSELAGE SKIN HAS 13 EACH CRACKS AROUND RIVET (APPROX. 1/16" LONG) AT FRAME 77 BETWEEN STR 3L-7L. E854459, E854460, E854461, AND E854462-C/A-REPAIRED SKIN AT FRAME 77 BETWEEN STR 3L-4L IAW SRM 53-32-01.-REPAIRED SKIN AT FRAME 77 BETWEEN STR 4L-5L IAW SRM 53-32SDR SIMA20210416007Skin · crackedFUSELAGE SKIN HAS 9 EACH CRACKS AROUND RIVET (APPROX. 1/16" LONG) AT FRAME 78 BETWEEN STR 5L-7L. (E854463, E854464) -C/A-REPAIRED SKIN AT FRAME 78 BETWEEN STR 6L-7L IAW SRM 53-32-01. AND REPAIRED SKIN AT FRAME 78 BETWEEN STR 5L-6L IAW SRM 53-32-01.SDR SIMA20210416006Skin · crackedFUSELAGE SKIN HAS 4 EACH CRACKS AROUND RIVET (APPROX. 1/16" LONG) AT FRAME 77 BETWEEN STR 3R-4R. -C/A-REPAIRED SKIN AT FRAME 77 BETWEEN STR 3R-4R IAW SRM 53-32-01.SDR SIMA20210416003Warning Message · false activationBLEED 1 LEAK EICAS MSG IN AIR. HAPPENED AFTER OR DIRECTLY AFTER ENTERING ICING DID NOT DECLARE EMERGENCY-C/A-PERFORMED DUCT LINE INSPECTION AND CHECK IAW EMB 145 36-11-09 AND PERFORMED ENGINE BLEED VALVE OPERATIONAL CHECK IAW 36-11-05. OPS CHECK GOODSDR SIMA20210416001Light · inoperativeEMERGENCY GALLEY LIGHT PLACARD INOP-C/A-T/S IAW EMB WM 33-50-50-005. RAR #2 EMERGENCY LIGHT DC INVERTER IAW EMB AMM 33-50-11-000-801-A AND 33-50-11-400-801-A. OPC GOOD.SDR SIMA20210416002Charger · inoperativeRH LWR EXTERIOR EMERGENCY LIGHT INOP-C/A-RAR #2 EMERGENCY LIGHT BATT AND CHARGER OPC GOOD IAW W/C 33-700-19SDR HNAA2021051900207Yoke · crackedLH ENGINE LWR FWD YOKE CRACKED. REMOVED AND REPLACED L/H FORWARD LOWER YOKE FITTING AND GUSSET PLATE IAW ETD2021-145-012599 AND EO1--54-21-0104.SDR HNAA2021051900206Drag Angle · crackedRH FUSELAGE TO VERTICAL STAB DRAG ANGLE IS CRACKED AT FWD FITTING AFT END. REMOVED AND REPLACED FWD RH FUSELAGE TO VERTICAL STABILIZER DRAG ANGLE IAW EMB 145 SRM 51-40-02.SDR SIMA20210415009Mount · crackedCARGO DOOR TORSION BAR MOUNT FLANGE IS CRACKED ON THE FWD. END AT FR 61RH. -C/A-RAI CARGO DOOR TORSION BAR MOUNT AT FRAME 61 IAW SRM 51-40-02.SDR SIMA20210415008Floor Support · crackedSSI CENTER OMEGA BEAM OUTBD SUPPORT ANGLE IS CRACKED JUST AFT OF FRAME 46 -C/A-REPAIRED CENTER OMEGA BEAM OUTBD SUPPORT ANGLE JUST AFT OF FR46 IAW SRM 53-23-02-RE AND SRM 51-40-02.SDR SIMA20210415007Bracket · crackedCARGO DOOR HOLD OPEN ROD BRACKET IS CRACKED ON THE FUSELAGE. -C/A-RAR'D CARGO DOOR HOLD OPEN ROD BRACKET IAW SRM 51-40-02.SDR SIMA20210415005Channel · crackedR/H HAT BEAM SUPPORT IS CRACKED BETWEEN FRAMES 47 AND 48. -C/A-REPAIRED RH HAT BEAM SUPPORT IAW SRM 53-23-02. AND SRM 51-40-02.SDR SIMA20210415006Support · corrodedCPCP SSI R/H FLOOR/WALL SUPPORT IS CORRODED FROM FRAMES 50-57.-C/A-RAR RH FLOOR/WALL SUPPORT FROM FRAMES 50-57 IAW EMB 145 SRM 51-40-02.SDR SIMA20210415002Battery Pack · inoperativeEMERGENCY FLOOR STRIPS 2 AND 3 INOP-C/A-RAR #2 BATTERY POWER SUPPLY AND #2 BATTERY IAW ENVOY WC 33-700-19. OPC GOOD. END.SDR SIMA20210415001Lamp · inoperativeMAIN DOOR EXTERNAL EMERGENCY LIGHT INOP-C/A-RAR MAIN DOOR EXTERNAL EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.SDR SIMA20210415004Warning Message · false activationBLD 2 LEAK ON CLIMB OUT DECLARED EMERGENCY -C/A-SUSPECT BAD DUCT LEAK DETECTOR.PERFORMED CONTINUITY TEST FORM CONNECTOR J1020 PN A-6 TO GROUND IAW SWPM 20-20-03. CONTINUITY TEST GOOD PIN A-6 HAS NO CONTINUITY TO GROUND.SDR HNAA2021051900205Skin · crackedREAR FUSELAGE II SKIN HAS POSSIBLE CRACKS AROUND 1 RIVET AT FR 78 BTW STRINGERS 4L-5L.REPAIRED REAR FUSELAGE II SKIN CRACKS AROUND 1 RIVET AT FR 78 BETWEEN STRINGERS 4L-5L IAW PIEDMONT EO1-53-21--0110.SDR HNAA2021051900204Skin · crackedREAR FUSELAGE II SKIN HAS POSSIBLE CRACKS AROUND 1 RIVET AT FR 78 BTW STRINGERS 6L-7L. REPAIRED REAR FUSELAGE II SKIN CRACKS AROUND 1 RIVET AT FR 78 BETWEEN STRINGERS 6L-7L IAW PIEDMONT EO1-53-21--0110.SDR HNAA2021051900202Skin · crackedREAR FUSELAGE II SKIN HAS POSSIBLE CRACKS AROUND 1 RIVET AT FR 77 BTW STRINGERS 8L-9L. REPAIRED REAR FUSELAGE II SKIN CRACKS AROUND 1 RIVET AT FR 77 BETWEEN STRINGERS 8L-9L IAW PIEDMONT EO1-53-21--0110.SDR JJBA20210414050Sealant · missingSEALANT MISSING FROM RIGHT LANDING GEAR NUT WHERE MAIN BRACE STRUT AND LOWER SIDE ARM CONNECT. APPLIED SEALANT TO RLG NUT.SDR HNAA2021041500156Anti-Ice Valve · inoperativeBLEED VALVE 1 CLOSED ON EICAS WITH ICE CONT- A/I INOP + WING A/I FAIL TROUBLE SHOOTING. R+R PNEUMATIC OVERHEAD PANEL AS REQ. OK FOR SERVICE.SDR HNAA2021041500155Warning Message · illuminatedPDIS 641 36-11 2387341 14APR21 RIC ASSGN
BLEED 1 VLV CLOSED MSG DISPLAYED ON EICAS IN FLIGHT
WITH WITH ICE COND A/I INOP AND WING A/I FAIL.
IN WORK AT RICSDR HNAA2021041501550Warning Message · illuminatedPDIS 626 78-30 2443681 14APR21 ERI ASSGN
E1 REV DISAGREE MSG ON EICAS .... MEL ASSIGNED - DEACTIVATED AND STOWED #1 T/R IAW AMM 78-31-01-980-801-ASDR HNAA2021041400154Switch · odorPDIS 602 05-00 14APR21 MDT, CLOSE STRONG ODOR IN BAGGAGE COMPARTMENT. FACT 14APR21 10:01 MDT, AFTER AIR OF COMPARTMENT NO ODOR NOTICED. SUSPECT LUBING OF BAG DOOR SWITCH DURING OVERNIGHT MTC.SDR SIMA20210413001Light · damagedLH EMERGENCY FLOOR LIGHT STRIP EXTRUSIONS #1,2,3,4,7,AND 8 ARE DAMAGED-C/A-COMPLETE:REPLACED L/H EMERGENCY FLOOR LIGHT STRIP EXTRUSIONS #1,#2,#3,#4,#7 AND #8 IAW AMM 33-50-12.SDR SIMA20210413002Stud · missingCEILING PANEL 253CLC AFT EMERGENCY EXIT SIGN MISSING MOUNTING STUD-C/A-COMPLETE:RAR CEILING PANEL 253CLC AFT EMERGENCY EXIT SIGN IAW AMM 20-10-01SDR SIMA20210413003Light · missing3 EMERGENCY FLOOR LIGHT INTERCONNECT STRIPS MISSING (STANDARD LENGTH)-C/A-COMPLETE:INSTALLED 3 EMERGENCY FLOOR LIGHT INTERCONNECT STRIPS DURING LIGHT STRIP INSTALL IAW AMM 33-50-12.SDR HNAA2021041400153Eicas · faultyPDIS 650, 31-41, 13APR21 PHL CLOSE, 300 FEET AFTER ROTATION, EICAS DISPLAY FLASHED BRIGHTLY AND WENT BLANK MOMENTARILY FOLLOWED BY AN ELECTRICAL ODOR. R&R'D EICAS DISPLAY UNIT AS REQUIRED PER AMM 34-22-01-400-801-A, OPS CHECK IAW 34-22-00-700-801A GOOD ON GROSDR HNAA2021041300141Smoke Detector · false activationLAV SMOKE EICAS MSG DISPLAYED IN FLT. PERFORMED INSPECTION OF LAV SMOKE DETECTOR. NO DEFECTS NOTED. C/W LAV SMOKE DETECTION SYSTEM IAW 26-14-00. SYS OPS NORMAL. OK FOR SERVICE. SUSPECT VAPING IN LAVSDR SIMA20210412002Battery Pack · misinstalledLAST 3 FLOOR EMERGENCY LIGHT STRIP INOP-C/A-T/S IAW EMB FIM 33-50-00-810-804-A. FOUND #4 BATTERY TO BE INSTALLED IMPROPERLY. INSTALLED BATTERY PACK IAW EMB AMM 33-50-04-400-802-A. OPS CHECK GOOD. NO DEFECTS NOTED. END.