SDR SIMA20140430005Grill · damagedAFTER WE LEVELED OFF AT CRUSE AT FL 270 & BEGAN ACCELERATING THROUGH ABOUT 280 KIAS WE HEARD A VIBRATION THAT WAS LOUDER THAN NORMAL, ALSO FOUND A STRONG RAPID VIBRATION IN BOTH CONTROL YOKES. SLOWED ACFT TO ABOUT 240 KIAS WHICH LESSENED THE STRENGTH OF THE VSDR ASOA20140430038Control Module · failedTHE CREW REPORTED AN ENGINE NR 2 FIRE DETECTOR FAILED MESSAGE DURING CRUISE. LASTED FOR FIVE MINUTES THEN WENT AWAY FOR ONE MINUTE THEN CAME BACK ON. THE ACFT LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE FIRE CONTROL MODULE IAW 26SDR SIMA20140430001Light · inoperativeSERVICE DOOR FAIRING EMERGENCY LIGHT INOPERATIVE. R & R EMERGENCY LIGHT LAMP IN SERVICE DOOR FAIRING IAW AMM 33-50-09-000-801-A & 33-50-09-400-801-A. OPERATIONS CHECKED GOOD AT THIS TIME.SDR SIMA20140429006Support · corrodedLEFT OMEGA BEAM AFT RAMP SUPPORT CORRODED FORWARD OF FRAME 20. R & R LT OMEGA BEAM AFT RAMP SUPPORT FWD FRAME 20 IAW SRM 51-20-01 & 51-40-02.SDR SIMA20140429004Wire · brokenEMERGENCY LIGHT STRIP NR 5 HAS A BROKEN WIRE ON FUSELAGE SIDE. REPAIRED EMERGENCY LIGHT STRIP NR 5 BROKEN WIRE CONNECTOR IAW SWPM 20-00-03, SWPM 20-21-00 & WM 91-10-02. SEE BOW 155716 FOR OPERATIONAL CHECK.SDR SIMA20140429005Support · crackedLEFT OTBD BEAM SUPPORT CRACKED AT FRAME 47. REMOVED CRACKED SUPPORT & INSTALLED SERVICEABLE BEAM SUPPORTS ON LT OTBD BEAM BETWEEN FRAMES 45 - 50 IAW SRM 53-23-02.SDR SIMA20140429007Support · crackedRIGHT INBD BEAM SUPPORT CRACKED AT FRAME 47. REMOVED CRACKED SUPPORT & INSTALLED SERVICEABLE BEAM SUPPORTS ON RT INBD BEAM BETWEEN FRAMES 45 - 50 IAW SRM 53-23-02.SDR SIMA20140429008Support · crackedRIGHT OTBD BEAM SUPPORT CRACKED AT FRAME 47. REMOVED CRACKED SUPPORT & INSTALLED SERVICEABLE BEAM SUPPORTS ON RT OTBD BEAM BETWEEN FRAMES 45 - 50 IAW SRM 53-23-02.SDR RAIA201404290001Rivet · corrodedTWO RIVETS HAVE CORROSION ON LOWER FUSELAGE BY FRAME 33. MAINTENANCE REPLACED TWO RIVETS.SDR CHQA20140429127Transceiver · faultyCREW REPORTED THAT THE WEATHER RADAR WAS INOPERATIVE. THE CREW DIVERTED THE ACFT & LANDED WITHOUT INCIDENT. REPLACED THE WEATHER RADAR RECEIVER & TRANSMITTER ASSEMBLY. OPERATIONAL CHECKS WERE GOOD WITH NO FURTHER DEFECTS NOTED.SDR SIMA20140429001Charger · inoperativeLT & RT OVERWING EMERGENCY LIGHTS INOPERATIVE. R & R BATTERY EMERGENCY LIGHT & BATTERY CHARGER ASSEMBLY IAW WC 33-700-19, OPERATIONS CHECKED GOOD.SDR SIMA20140429002Control Unit · failedON LANDING BRAKE DEGRADE MSG FLASHED ON EICAS BRAKES WORKED ABOUT 1/2 NORMAL. USED THRUST REVERSE TO STOP. BRAKE TEMP ON OTBD BRAKES HIGH TO MID AMBER RANGE. INBD BRAKE TEMP LOW TO MID GREEN RANGE. R & R BCU IAW AMM 32-41-02, OPERATIONS CHECKED GOOD.SDR SIMA20140428008Frame · crackedCOCKPIT UNDERFLOOR ACCESS HATCH FRAME IS CRACKED UNDER ATTACHMENT PIN BRACKET. COMPLIED WITH ERS-EM-5200-140.SDR SIMA20140428006Stringer · corrodedSTRINGER 21R IS CORRODED BETWEEN FRAMES 12 - 13. REMOVED & INSTALLED NEW STRINGER 21R IAW SRM 51-40-02, SEE TURNOVER FOR DETAILS.SDR SIMA20140428009Gusset · corrodedDIAMOND GUSSET ON RT FLOORBEAM & FRAME 20 IS CORRODED. R & R DIAMOND GUSSET ON RT FLOORBEAM & FRAME 20 IAW SRM 51-20-01, 51-40-02 & 51-20-03. RESTORED SURFACE PROTECTION TO DIAMOND GUSSET ON RT FLOORBEAM & FRAME 20 IAW CPM 51-21-06 & ETN'S GN-51-011R4, EM-51SDR SIMA20140428007Connector · brokenPANEL 811XW EMERGENCY LIGHT CONNECTOR BROKEN. R & R ELEC CONNECTOR, PLASTIC FEMALE RECEPTACLE ONLY, ON PAX DOOR EMERGENCY LIGHT, PANEL 811XW IAW SWPM 20-50-00 & 20-21-00 & IAW AMM 33-50-00. OPERATIONAL TEST GOOD.SDR SIMA20140428003Battery Pack · dischargedLT & RT OVERWING EMERGENCY LIGHTS INOPERATIVE. R & R BATTERY PACK & CHARGER FOR LT & RT OVERWING EMERGENCY LIGHTS IAW AMM 33-51-17.SDR SIMA20140428001Battery · dischargedLT & RT OVERWING EMERGENCY LIGHTS INOPERATIVE. R & R NR 4 BATTERY PACK & CHARGER ASSEMBLY.SDR SIMA20140428004Charger · inoperativeEMERGENCY CEILING LIGHT AT PAX SEAT 16A INOPERATIVE BULB WAS REPLACED LIGHT STILL NOT WORKING. R & R BATTERY PACK & CHARGER FOR EMERGENCY CEILING LIGHT AT PAX SEAT 16A IAW AMM 33-51-17. IAW NRWC 675-MQT-01527 FOR PART R & R INFORMATION.SDR SIMA20140428002Light · malfunctionedRIGHT LARGE EMERGENCY LIGHT AT RT WING EXIT HATCH INOPERATIVE. RESET EXTERNAL DC POWER SUPPLY & PERFORMED EMERGENCY LIGHT OPERATIONAL CHECK IAW AMM 33-50-00. OPERATIONS CHECKED GOOD, NO DEFECTS NOTED.SDR SIMA20140428005Light · inoperativeEMERGENCY LIGHTING STRIP ROW 16 INOPERATIVE. R & R LIGHTING STRIP IAW AMM 33-50-12, OPERATIONS CHECKED GOOD.SDR ASOA20140428064Skin · crackedDURING 4A, INSPECTION THE LT AFT FUSELAGE SKIN WAS FOUND TO BE CRACKED 2.81MM LONG AT A RIVET ON FRAME 79, 1 RIVET BELOW STRINGER 6L. MAINTENANCE REMOVED THE DAMAGE AND PERFORMED A BUSHING REPAIR IAW DER APPROVED ETD2014-145-035517, AND THE ACFT WAS APPROVED SDR ASOA20140428065Attach Angle · crackedDURING 4A INSPECTION, THE RT VERTICLE STAB TO FUSELAGE ATTACH ANGLE WAS FOUND TO HAVE A CRACK EXTENDING 22.43MM. MAINTENANCE R & R THE AFFECTED ANGLE, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR CHQA20140427142Structure · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE LOWER FWD PAX DOOR STRUCTURE. THE LOWER FWD PAX DOOR STRUCTURE WAS REPLACED IAW SRM 51-40-02.SDR RAIA201404270005Channel · corrodedLOWER SERVICE DOOR CHANNEL, DOOR FRAME HAS CORROSION. MAINTENANCRE REPLACED LOWER SERVICE DOOR FRAME.SDR RAIA201404270004Door Sill · corrodedFORWARD SERVICE DOOR SILL HAS CORROSION. MAINTENANCE REPLACED FORWARD SERVICE DOOR SILL.SDR RAIA201404270003Floor Support · corrodedLT OMEGA BEAM HAS CORROSION AT FR20. MAINTENANCE REPLACED LT OMEGA BEAM AT FR20.SDR RAIA201404270002Support · corrodedCENTER RAMP SUPPORT HAS CORROSION AT FRAME 20. MAINTENANCE REPLACED CENTER RAMP SUPPORT.SDR RAIA201404270001Gusset · corrodedCENTER GUSSET HAS CORROSION BETWEEN FRAMES 20 AND 22. MAINTENANCE REPLACED CENTER GUSSET.SDR SIMA20140427003Charger · inoperativeBOTH AFT WING EMERGENCY LIGHTS INOPERATIVE. R & R NR 4 EMERGENCY BATTERY & CHARGER ASSEMBLY IAW WC 33-700-19. OPERATIONS CHECKED GOOD IAW WC 33-700-17.SDR SIMA20140427004Battery · dischargedEMERGENCY BATTERY POWER SUPPLY NR 3 INOPERATIVE. R & R BATTERY ASSEMBLY & CHARGER FOR EMERGENCY BATTERY POWER SUPPLY NR 3 IAW WC 33-700-19. OPERATIONS CHECKED IAW WC 33-700-17.SDR RAIA201404260002Housing · corrodedLAVATORY DRAIN CUP HOUSING CORRODED. MAINTENANCE REPLACED LAVATORY DRAIN CUP HOUSING.SDR RAIA201404260001Door Sill · corrodedCARGO BAY SILL PLATE HAS CORROSION. MAINTENANCE REPLACED CARGO BAY SILL PLATE.SDR SIMA20140426003Sill · corrodedDURING HMBV INSPECTION FOUND CARGO DOOR SILL IS CORRODED IN SEVERAL SPOTS. R & R CARGO DOOR SILL IAW SRM CHAPTER 51-40-02.SDR SIMA20140426002Battery · dischargedFLOOR PROXIMITY LIGHTS AT 251FF, 251HF & 261BF INOPERATIVE. R & R NR 4 EMERGENCY LIGHT BATTERY & CHARGER IAW AMM 33-50-04, OPERATIONS CHECKED GOOD.SDR CHQA20140425132Fitting · crackedDURING INSPECTION, THE SHEAR CLIP AT FRAME 81 & STRINGER 10L WAS FOUND TO BE CRACKED. THE SHEAR CLIP WAS REPLACED IAW SRM 51-40-02.SDR CHQA20140425131Fitting · crackedDURING INSPECTION, THE SHEAR CLIP AT FRAME 81 & STRINGER 10R WAS FOUND TO BE CRACKED. THE SHEAR CLIP WAS REPLACED IAW SRM 51-40-02.SDR RAIA201404250002Bulb · inoperativeCEILING EMERGENCY EXIT LIGHT AT ROW 23 IS INOPERATIVE. MAINTENANCE REPLACED BULB, OPS CHECK GOOD.SDR CHQA20140425124Light · inoperativeDURING INSPECTION, THE EMERGENCY FLOOR PROXIMITY STRIP LIGHT AT ROWS 8 & 9 WAS FOUND TO BE INOPERATIVE. REPLACED THE EMERGENCY FLOOR STRIP LIGHT. OPERATIONAL CHECKS WERE GOOD WITH NO FURTHER DEFECTS NOTED.SDR SIMA20140425007Beam · corrodedGALLEY RT HAT BEAM HAS CORROSION AT NUTPLATE HOLE AT FRAME 23. REPAIRED IAW ERS-EM-53MR-407.SDR SIMA20140425005Charger · inoperativeDURING PS 2, FOUND REAR EXTERIOR OVERWING EMERGENCY LIGHTS INOPERATIVE. R & R NR 4 EMERGENCY BATTERY & BATTERY CHARGER IAW AMM 33-50-04. R & R RT EXTERIOR OVERWING EMERGENCY LIGHT ASSEMBLY IAW AMM 33-50-10, OPERATIONS CHECKED GOOD.SDR SIMA20140425004Unknown · odorAFTER SETTING TAKEOFF POWER INTENSE BURNING ODOR THROUGHOUT ENTIRE ACFT. NO VISIBLE SMOKE OR FUMES HIGHEST SPEED ABORT. ACCOMPLISHED ODOR DISSIPATED AT IDLE THRUST. A FLUSH OF INTERNAL SURFACE OF BOTH ENGS USING FOAM, COMP WASH, WAS PERFORMED LAST NIGHT. SSDR SIMA20140425006Flashlight · looseAFT CABIN FLASHLIGHT IS LOOSE IN HOLDER, SAFETY HAZARD. R & R AFT CABIN FLASHLIGHT & CHARGER ASSEMBLY, OPERATIONS CHECKED GOOD IAW AMM 33-50-16.SDR SIMA20140425003Pitot Line · contaminatedIAS MSG ON BOTH CAPTAIN & FIRST OFFICER AIRSPEED, PERFORMED A CHECKLIST & CAPTAIN`S WAS CORRECT. FOUND WATER IN PITOT LINES & DRAINED IAW AMM 34-13-00. PERFORMED OPERATIONAL CHECK OF PITOT STATIC SYS IAW AMM 34-13-00.SDR CHQA20140424123Proximity Switch · faultyCREW REPORTED THAT THEY RECEIVED A LG AIR & GND FAIL MSG IN FLIGHT. THE CREW RETURNED TO FIELD & LANDED WITHOUT INCIDENT. FOUND THE NLG WEIGHT ON WHEELS SWITCH TO BE FAULTY. THE SWITCH WAS SWAPPED WITH THE LT MLG DOWNLOCK PROXIMITY SWITCH & DEFERRED. THE DSDR SIMA20140424003Acm · damagedWHILE CRUISING AT FL250, WE ENCOUNTERED INSTANTANEOUS SMOKE IN THE COCKPIT & CABIN. VISUAL INSPECTION FOUND LT ACM DAMAGE. R & R LT ACM IAW AMM 21-51-03. OPERATIONAL CHECK FOUND OK. NO SMOKE IN THE COCKPIT OR CABIN AT THIS TIME.SDR SIMA20140424001Roller · dirtyPAX DOOR HARD TO OPEN. PERFORMED CLEANING & LUBE DOOR ROLLERS IAW AMM 53-21-02, OPERATIONS CHECKED GOOD.SDR SIMA20140423008Door Sill · corrodedDURING HMBV INSPECTION FOUND THE SERVICE DOOR SILL HAS AREAS OF CORROSION BETWEEN FRAMES 20 - 22. R & R SERVICE DOOR SILL IAW SRM 51-40-02.SDR CHQA20140423144Structure · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE INNER STRUCTURE OF THE LOWER AFT CORNER OF THE MAIN ENTRY DOOR. THE LOWER AFT CORNER STRUCTURE OF THE LOWER MAIN ENTRY DOOR WAS REPLACED IAW SRM 51-40-02.SDR CHQA20140423143Reinforcement · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE DOOR STOP REINFORCEMENT INSIDE OF THE FWD FRAME OF THE MAIN ENTRY DOOR. THE DOOR STOP REINFORCEMENT WAS REPLACED IAW SRM 51-40-02.
Back to Embraer EMB-145LR