Embraer EMB-145LR
Service difficulty reports · 36,799
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20131207001Battery · dischargedLEFT & RT OVERWING & LAST FLOOR STRIP EMERGENCY LIGHTS INOPERATIVE. R & R NR 4 EMERGENCY BATTERY & CHARGER IAW 145 AMM 33-50-04, OPERATIONS GOOD.SDR ASOA20131207455Threshold · corrodedPAX DOOR THRESHOLD AFT NUT PLATE CORRODED BEYOND LIMITS. R & R CORRODED ANGLE.SDR ASOA20131207454Floor Support · corrodedRIGHT OMEGA BEAM AT FRAME 20 CORRODED BEYOND LIMITS. R & R OMEGA PLATE.SDR ASOA20131207453Floor Support · corrodedRIGHT FLOOR SUPPORT AT FRAME 22 CORRODED BEYOND LIMITS. R & R FLOOR SUPPORT.SDR CHQA20131206442Smoke Detector · false activationCREW REPORTED THAT THEY RECEIVED A LAVATORY SMOKE MESSAGE ON CLIMB OUT. THE CREW FURTHER REPORTED NO VISIBLE SMOKE. THE SMELL OF DE-ICING FLUID WAS REPORTED AS PRESENT IN THE AIRCRAFT. THE CREW RETURNED TO FIELD & LANDED WITHOUT INCIDENT. MX RAN THE ENGS WSDR SIMA20131206001Flashlight · defectiveFLIGHT ATTENDANT`S FLASHLIGHT DOES NOT CHARGE. R & R FLASHLIGHT IAW AMM 33-50-16. OPERATIONS CHECKED GOODSDR SIMA20131206003Flashlight · defectiveAFT CABIN EMERGENCY FLASHLIGHT DIM. R & R AFT CABIN EMERGENCY FLASHLIGHT IAW 145 AMM 33-50-16-000-801-A & 33-50-16-400-801-A. OPERATIONS CHECKED GOOD.SDR ASOA20131203212Skin · crackedDURING A-CHECK INSPECTION, LEFT FUSELAGE SKIN WAS FOUND TO HAVE A FREE FLOATING HORIZONTAL CRACK MEASURING 9.07 MM, 0.35", WITH A 3.47 MM, 0.13", CRACK TRAVELING UP FROM IT AT FRAME 75 ABOVE STRINGER 2L. MAINTENANCE REMOVED THE DAMAGED SECTION OF SKIN AND PERSDR ASOA20131203211Profile · crackedDURING A-CHECK INSPECTION, LEFT L-PROFILE, DRAG ANGLE WAS FOUIND TO BE CRACKED AT FRAME 76. MAINTENANCE R & R PROFILE, AND ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20131203210Skin · crackedDURING A-CHECK INSPECTION, RT SIDE FUSELAGE SKIN WAS FOUND TO BE CRACKED FRAME 75 BELOW STRINGER 2R. MAINTENANCE REMOVED THE DAMAGE AND PERFORMED A DOUBLER REPAIR, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20131206085Power Supply · inoperativeTHE CREW REPORTED LT FORWARD EXTERNAL EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE INSPECTED AND REPLACED THE EMERGENCY LIGHT POWER SUPPLY. OPS CHECKED GOOD.SDR ASOA20131206452Floor Support · corrodedTOP PLATE ON CENTER OMEGA NEAR FRAME 61 CORRODED BEYOND LIMITS. R & R GUSSET.SDR ASOA20131206451Profile · corrodedCORROSION BEYOND LIMITS AROUND NR 2 & NR 3 NUTPLATE HOLES IN MAIN DOOR BOTTOM STRUCTURE. INSTALLED 2 REPAIR DOUBLERS IAW EC5210-01154.SDR ASOA20131206450Floor Support · corrodedTOP PLATE ON LT OMEGA BEAM CORRODED BEYOND LIMITS NEAR FRAME 60. R & R FLOOR SUPPORT.SDR RAIA201312050002Thermal Switch · inoperativeBLEED 2 LEAK DURING CRUISE, ACFT RETURNED. MAINTENANCE INSPECTED AND R & R THERMAL SWITCH AT AIR STARTER INLET AND PERFORMED BLEED LEAK TEST. NO DEFECTS NOTED AT THIS TIME.SDR RAIA201312050001Structure · corrodedPASSENGER DOOR HAS CORROSION. MAINTENANCE REPLACED CORRODED PARTS OF PASSENGER DOOR.SDR SIMA20131205005Light · inoperativeMAIN DOOR EMERGENCY LIGHT INOPERATIVE. R & R MAIN DOOR EMERGENCY LIGHT LAMP IAW AMM 33-50-06-000-801-A & 33-50-06-400-801-A. OPERATIONS CHECKED GOOD, NO DEFECTS NOTED.SDR SIMA20131205003Light · inoperativeEMERGENCY LIGHT ON PAX DOOR INOPERATIVE. R & R BULB ON PAX DOOR EMERGENCY LIGHT IAW 145 AMM-33-50-06, OPERATIONS CHECKED GOOD.SDR SIMA20131205002Flashlight · inoperativeFLASHLIGHT ABOVE FLIGHT ATTENDANT SEAT INOPERATIVE. R & R FLASHLIGHT IAW 145 AMM 33-50-16, OPERATIONS GOOD.SDR SIMA20131205007Power Supply · inoperativeEMERGENCY LIGHTING SYS OVERWING INOPERATIVE. REMOVED & INSTALLED NEW NR 4 EMERGENCY LIGHTING BATTERY POWER SUPPLY PER WORK CARD 33-700-19.SDR SIMA20131205004Flashlight · inoperativeCOCKPIT FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT IN COCKPIT IAW AMM 33 50 16. OPERATIONS CHECKED GOOD.SDR ASOA20131206449TFloorbeam · corrodedFLOORBEAM AT FRAME 23 BETWEEN RT AND CENTER OMEGA BEAMS CORRODED BEYOND LIMITS. R & R FLOORBEAM ANGLE.SDR SIMA20131203004Light · inoperativeNUMBER 4 LT FLOOR PROXIMITY STRIP LIGHT BROKEN. REPLACED NR 4 LT FLOOR PROXIMITY STRIP LIGHT IAW EMB 145 AMM 33-50-12.SDR ASOA20131202084Sign · inoperativeTHE CREW REPORTED EMERGENCY EXIT LIGHT WAS INOPERATIVE ON BULKHEAD. MAINTEANCE REPLACED THE EMERGENCY EXIT SIGN. OPS CHECKED GOOD.SDR SIMA20131202006Sign · inoperativeEMERGENCY EXIT SIGN OVER SERVICE DOOR INOPERATIVE. R & R EMERGENCY EXIT SIGN OVER SERVICE DOOR IAW EMB AMM 33-50-14-000-801-A & 33-50-14-400-801-A. OPERATIONS CHECKED GOOD.SDR SIMA20131202005Frame · corrodedFR 13 IS CORRODED BETWEEN STRINGER 21L & 21R. REPAIRED FR 13 IAW AE ERS-EM-53MR-053.SDR SIMA20131202004Skin · groovedRUDDER 1 LE GROOVED. REPAIRED RUDDER 1 GROOVED AREA ON LE IAW ERS-EM-55MR-009.SDR SIMA20131202003Frame · gougedMACHINED FRAME AT FR 70 AT APPROXIMATELY STRINGER 13R GOUGED ON FACE. REPAIRED FRAME 70 IAW AE ERS-EM-53MR-052.SDR SIMA20131202002Floorbeam · corrodedRIGHT LAVATORY FLOOR BEAM BETWEEN FR 59 - 61 CORRODED AROUND NUTPLATE HOLES. REPAIRED LAVATORY FLOOR BEAM IAW ERS-EM-53MR -051.SDR SIMA20131202001Light · inoperativeLEFT WING AFT EMERGENCY LIGHT INOPERATIVE. R & R LT WING AFT EMERGENCY LIGHT IAW EMB 145 AMM 33-50-10, OPERATIONS CHECKED GOOD.SDR SIMA20131201002Spar · crackedDURING HMBV INSPECTION LT WING SPAR 3 CRACK REPAIR REQUIRES EO-EM-57MR-682 PT. COMPLETED REPAIR OF LT WING SPAR III WEB IAW EO EM-57MR-682 R2 PTB.SDR CHQA20131201451Fitting · crackedA CRACK WAS FOUND IN THE SHEAR CLIP AT FRAME 25 BETWEEN STRINGERS 15R & 16R. THE SHEAR CLIP WAS REPLACED IAW SRM 51-40-02.SDR CHQA20131201450Fitting · crackedA CRACK WAS FOUND IN THE SHEAR CLIP AT FRAME 24 BETWEEN STRINGERS 15R & 16R. THE SHEAR CLIP WAS REPLACED IAW SRM 51-40-02.SDR CHQA20131201449Sill · crackedA CRACK WAS FOUND IN THE STRINGER FRAME SILL AT STRINGER 3L. THE FRAME SILL WAS REPLACED IAW SRM 51-40-02.SDR CHQA20131201448Floor Support · crackedA CRACK WAS FOUND ON THE RT OMEGA BEAM OTBD SUPPORT BETWEEN FRAMES 47 & 48. THE OMEGA BEAM SUPPORT WAS REPLACED IAW SRM 51-40-02.SDR CHQA20131201447Floor Support · crackedA CRACK WAS FOUND ON THE LT OMEGA BEAM OTBD SUPPORT BETWEEN FRAMES 47 & 48. THE OMEGA BEAM SUPPORT WAS REPLACED IAW SRM 51-40-02.SDR SIMA20131201001Light · inoperativeAFT CABIN CEILING EMERGENCY LAMP INOPERATIVE. R & R AFT CABIN CEILING EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-08-000-801-A & 33-50-08-400-801-A. OPERATIONS CHECKED GOOD.SDR SIMA20131130004Light · inoperativeBACK LIGHTING AROUND EMERGENCY LIGHT SWITCH IS INOPERATIVE. R & R EMERGENCY LIGHT PANEL ILLUMINATED PLACARD ASSEMBLY IAW AMM 20-13-10, OPERATIONAL TEST GOOD.SDR SIMA20131130003Holder · failedBATTERY HOLDER ASSEMBLY FAILS CHECKS. R & R BATTERY HOLDER ASSEMBLY.SDR SIMA20131130002Sign · unsecureOVERHEAD EXIT SIGN IN CEILING FALLING DOWN 12A. SECURED CTR AISLE EXIT SIGN AT ROW 12 IAW STANDARD MTX PRACTICES.SDR SIMA20131130001Handle · crackedMAIN CABIN DOOR INNER HANDLE CRACKED, CAUSING DOOR NOT TO OPEN. R & R MAIN CABIN DOOR INNER ACTUATING HANDLE IAW EMB-145 AMM 52-18-05. OPERATIONS CHECKED GOOD, NO FURTHER DEFECTS NOTED.SDR RAIA201311300002Bulb · inoperativeRIGHT OVERWING EMERGENCY EXIT LIGHT, FWD OF WING, IS INOPERATIVE. MAINTENANCE REPLACED RIGHT OVERWING EXIT BULB, OPS CHECKED GOOD.SDR RAIA201311300001Bulb · inoperativeLEFT OVERWING EMERGENCY EXIT LIGHT IS INOPERATIVE. MAINTENANCE REPLACED BULB, OPS CHECKED GOOD.SDR SIMA20131129010Battery · dischargedEMERGENCY LIGHTING SYS BATTERY CHARGER ASSEMBLIES FOR BATTERY NR 3 & BATTERY NR 4 ARE INOPERATIVE. R & R EMERGENCY LIGHTING SYS BATTERY POWER SUPPLIES & BATTERY PACKS FOR BATTERIES NR 3 & NR 4 IAW AMM 33-50-04, OPERATIONS CHECKED GOOD.SDR SIMA20131129009Charger · failedBATTERY CHARGER ASSEMBLY FAILS CHECK. R & R BATTERY CHARGER ASSEMBLY.SDR SIMA20131129007Connector · not seatedFORWARD GALLEY CEILING PANEL EMERGENCY LIGHT INOPERATIVE. FOUND CONNECTOR TO NR 1 EMERGENCY POWER SUPPLY NOT CONNECTED CORRECTLY. RESEATED THE CONNECT TO THE NR 1 EMERGENCY POWER SUPPLY IAW EMB145 FIM 33-50-00-810-804-A, SYS CHECKED GOOD IAW EMB145 AMM 33-50SDR SIMA20131129008Connector · not seatedLEFT FWD BELLY EMERGENCY LIGHT INOPERATIVE. TROUBLESHOOT THE LT FWD BELLY EMERGENCY LIGHT INOPERATIVE IAW EMB145 FIM 33-50-00-810-804-A. FOUND CONNECTOR TO NR 1 EMERGENCY POWER SUPPLY NOT CONNECTED CORRECTLY. RESEATED THE CONNECTOR TO THE NR 1 EMERGENCY POWSDR SIMA20131129006Light · inoperativeEMERGENCY LIGHT STRIP AT ROW 11 & 12 IS INOPERATIVE. R & R FLOOR PROXIMITY LIGHT AT ROW 11 & 12 IAW EMB-145 AMM 33-50-12, OPERATIONS CHECKED GOOD.SDR SIMA20131129004Flashlight · looseAFT CABIN FLASHLIGHT IS LOOSE. R & R EMERGENCY FLASHLIGHT AFT CABIN IAW EMB AMM 33-50-16.SDR SIMA20131129003Light · inoperativeRIGHT WING UPPER EMERGENCY LIGHT INOPERATIVE. R & R RT WING UPPER EMERGENCY LIGHT BULB IAW EMB AMM 33-50-10. OPERATIONS CHECKED GOOD IAW AE WC 33-700-17.
Back to Embraer EMB-145LR