Embraer EMB-145LR
Service difficulty reports · 36,799
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20130824001Controller · failedFLIGHT 3051, CREW REPORTED A RAPID DECOMPRESSION AT 34000 FT. CABIN ALTITUDE CLIMBED ABOVE 10000. PERFORMED MEMORY ITEMS AND INITIATED AN EMERGENCY DESCENT. 02 MASK DEPLOYED AUTOMATICALLY. ACFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. ACFT REMOVESDR SIMA20130823004Wire · damagedWIRE HARNESS TO EMERGENCY LIGHT NR 3 HAS DAMAGED INSULATION NEAR THE ELECTRICAL CONNECTOR. REPAIRED WIRE IAW SPWM 20-21-00. OPS TEST GOOD.SDR ASOA20130823100Sign · inoperativeDURING MX INSPECTION, THE SEAT 12BC EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. R & R EMERGENCY EXIT & OPS CHECKED SUCCESSFUL. ACFT RETURNED TO SERVICE.SDR SIMA20130823001Unknown · odorNR 2 PACK IN AUTO MODE, F/A AND PASSENGERS REPORTED A BAD ODOR AND EXCESSIVE HEAT TOWARDS BACK OF ACFT. PERFORMED OPS CHECK OF NR 2 PACK IAW AMM 21-51-00. OPS CHECK GOOD AT THIS TIME COULD NOT DUPLICATE ODOR AND CABIN COOLING PROPERLY.SDR CHQA20130823325Ballast · inoperativeDURING TAXI, CREW REPORTED A BURNING ODOR AND VISIBLE SMOKE IN THE CABIN COMING FROM THE CABIN LIGHTING BALLAST AT ROW 1. RETURNED TO GATE, REPLACED BALLAST. NO FURTHER DEFECTS HAVE BEEN NOTED.SDR CHQA20130822329Frame · damagedDURING INSPECTION, A HOLE WAS FOUND ON THE RT SIDE OF FRAME 65 BETWEEN STRINGERS 12R AND 13R. THE FRAME WAS REPAIRED IAW ETD 2013-145-032262.SDR CHQA20130822328Support · crackedDURING INSPECTION, A CRACK WAS FOUND IN THE RT INBD OMEGA BEAM SUPPORT AT FRAME 47 AND 48. THE OMEGA BEAM SUPPORTS WERE REPLACED IAW SRM 51-40-02.SDR CHQA20130822327Channel · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE REPAIR DOUBLER OF LT OMEGA FRAME 20. THE DOUBLER WAS REPLACED IAW SRM 53-00-10.SDR CHQA20130822326Frame · bentDURING INSPECTION, FRAME 72 WAS FOUND BENT AT STRINGER 16R. FRAME REPAIRED IAW ETD 2013-145-032192-A.SDR ASOA20130822099Wire Harness · arcedPILOT REPORTED A BURNING ODOR IN THE FWD GALLEY NEAR SEAT 1A. MX INSPECTED AND FOUND SEATS 1A, 3A, AND 4A SOCKETS BURNED. R & R SEAT 1A AND 3A LIGHT SOCKETS AND 4A LIGHT SOCKET HARNESS WITH OPS CHECK SUCCESSFUL AND NO BURNED SMELL NOTED. ACFT WAS APPROVED FSDR SIMA20130821003Flashlight Assy · inoperativeFWD F/A EMERGENCY FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT IAW AMM 33-55-16. OPS CHECKED GOOD.SDR SIMA20130821001Roller · lack of lubeF/A REPORTS MAIN DOOR HARD TO OPEN/CLOSE. CLEANED & LUBBED MAIN DOOR ROLLERS IAW MM 52-18-05. OPS CK OF DOOR GOOD AT THIS TIME.SDR SIMA20130821004Lamp · inoperativeSERVICE DOOR EXTERNAL EMERGENCY LIGHT INOPERATIVE. R & R LAMP IAW AMM TASK 33-50-09-000-801-A AND 33-50-09-400-801-A. OPS CHECKED GOOD.SDR SIMA20130820003Stringer · corrodedSTRINGER 20R CORRODED BETWEEN FR 13-17. REPAIRED IAW AEA EO EM-53MR-2183.SDR SIMA20130820002Skin · corrodedEXTERNAL SKIN CORRODED BETWEEN FR 13-14, STR 18R-20R. REPAIRED IAW EO -EM-53MR-2182.SDR ASOA20130820098Unknown · odorCREW REPORTED A BAD ODOR COMING FROM NR 2 PACK DURING DESCENT. MX PERFORMED GROUND OPS CHECK OF NR 2 PACK SYS SUCCESSFUL WITH NO DEFECTS NOTED. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR CHQA20130820320Battery Pack · inoperativeDURING INSPECTION, NR 4 AND 5 EMERGENCY LIGHTS FOUND TO BE INOPERATIVE. REPLACED BATTERY PACK AND OPS CHECKED GOOD.SDR SIMA20130819002Skin · damagedCREW REPORTED A BIRD STRIKE AT 12,000 FT, ON LT NOSE. A 6 INCH HOLE IN THE NOSE. ACFT REMOVED FROM SERVICE. REMOVED FUSELAGE SKIN AT FRAMES 1A TO 3 LT IAW SRM 51-40-02. REPLACED SKIN PANEL AND FRAME 2 ON LT FOWARD FUSELAGE 1 IAW SRM 51-40-02. ACFT RETURNED SDR CHQA20130819315Gate · out of rigCREW REPORTED THE MAIN ENTRY DOOR SQUEALED DURING FLIGHT. RETURNED TO FIELD AND LANDED WITHOUT INCIDENT. MX ADJUSTED THE GATE. PRESSURE CHECKED GOOD, NO NOISE OR LEAKS NOTED.SDR ASOA20130818096Light · inoperativeDURING MX INSPECTION THE EMERGENCY LIGHT FLOOR STRIP AT SEATS 18 AND 19A WERE FOUND INOPERATIVE. MX R & R LIGHT, OPS CHECKED SUCCESSFUL. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR CHQA20130818317Sending Unit · faultyDURING DESCENT THEY RECEIVED A FUEL 1 LO LEVEL WARNING AND FUEL IMBALANCE CAUTION MESSAGE. THE CREW DECLARED A FUEL EMERGENCY AND LANDED WITHOUT INCIDENT. MX ISOLATED THE ISSUE TO THE WING TANK FUEL QTY INDICATION AND DEFERRED THE INDICATION. REPLACED THE NRSDR SIMA20130818002Unknown · odorENTIRE PLANE SMELLS LIKE A BAD LAVATORY. R & R TOILET SHROUD FOR GENERAL VISUAL INSPECTION IAW AMM 25-40-04. DID NOT VIEW ANY POSS. LEAKS, OPS CHECK GOOD.SDR SIMA20130818005Light · inoperativeNR 5 FLOOR EMERGENCY LIGHT NOT WORKING. R & R NR 5 EMERGENCY LIGHT IAW AMM 33-50-12.SDR SIMA20130818007Battery · inoperativeCOCKPIT EMERGENCY FLASHLIGHT INOPERATIVE. R & R COCKPIT EMERGENCY FLASHLIGHT BATTERY IAW AMM 33-50-16. OPS CHECKED GOOD.SDR CHQA20130817319Battery · inoperativeDURING INSPECTION, LT OVERWING EMERGENCY EXIT LIGHT FOUND TO BE INOPERATIVE. MX REPLACED LIGHT AND NR 1 BATTERY ASSEMBLY. OPS CHECKED GOOD AND NO FURTHER DEFECTS NOTED.SDR CHQA20130817318Light · inoperativeDURING INSPECTION, LT OVERWING EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. MX REPLACED THE LIGHT AND THE NR 1 BATTERY ASSEMBLY. OPS CHECKED GOOD AND NO FURTHER DEFECTS NOTED.SDR SIMA20130817004Unknown · unknownMULTIPLE EMERGENCY LIGHTS OUT. PERFORMED OPS CHECK OF EMERGENCY LIGHTS IAW AE WC 33-700-17, OPS CHECKED GOOD.SDR SIMA20130817001Engine · leakingAFTER TAKEOFF THEY GOT A LAVATORY SMOKE WARNING. NO SMOKE SEEN, NOTICED AN ELECTRICAL ODOR. RETURNED TO DEPARTURE AND LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. FOUND OIL POOLING BEHIND THE IVG'S AT THE 6 O`CLOCK POSITION IAW ETN-EM-79-014 ON THESDR CHQA20130816316Light · inoperativeDURING INSPECTION, THE LT OVERWING EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. MX REPLACED THE LIGHT. OPS CHECKED GOOD AND NO FURTHER DEFECTS WERE NOTED.SDR SIMA20130816001Sensor · inoperativeCREW REPORTED DURING DESCENT, EXPERIENCED A FLAP AND SPOILER MALFUNCTION. PERFORMED THE PROCEDURES IAW AOM VOL 1, DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. R & R THE LT & RT FLAP VELOCITY SENSOR IAW AMM 27-51-12. THE OPSSDR SIMA20130815012Connector · missingFLOOR PROXIMITY LIGHT STRIP WIRE HARNESS HAS A CONNECTOR MISSING. REPAIRED FLOOR PROXIMITY, EMERGENCY LIGHT STRIP WIRE W192-8760-22 IAW SWPM 20-21-00.SDR SIMA20130815009Cover · crackedEIGHT FLOOR PROXIMITY LIGHT STRIP PANEL COVERS CRACKED. R & R 8 EA PANEL COVERS FOR FLOOR LIGHT PROXIMITY STRIPS AS REQUIRED SEE BOW 136806 FOR REMOVAL AND REINSTALLATION OF PROXIMTY FLOOR LIGHT STRIPS.SDR SIMA20130815011Wire · damagedNR 8 FLOOR PROXIMITY LIGHT STRIP HAS DAMAGED WIRE. R & R NR 8 EMERGENCY PROXIMITY LIGHT STRIP FROM THE PANEL COVER AS REQUIRED, BOW136806 FOR EMERGENCY LIGHT STRIPS REMOVAL AND REINSTALLMENT.SDR SIMA20130815008Battery · inoperativeR & R EMERGENCY LIGHTING BATTERY ASSY, BATTERY CHARGER, WC 33-700-19, WC 33-002, NR 4 PN 2013-1A, SN 68535- EMERGENCY LIGHTING BATTERY ASSY/ BATTERY CHARGER, WC 33-700-19, NR 4, PN 2013-1A, SN 68535 WAS REPLACED AT SGF ON 07 AUG 2013. VERIFIED ON VISUAL INSPESDR SIMA20130815007Structure · crackedREAR ELECTRONICS COMPARTMENT DOOR INNER EDGE CRACKED AROUND 2 RIVETS ON UPPER MOUNTING CLIP. REPAIRED CRACK IAW EO EM-52MR-366. WC 52-200-07, CRACK LENGTHS .20, .23, .30, .25.SDR SIMA20130815006Battery · inoperativeBATTERY DID NOT CHARGE. REMOVED BATTERY.SDR SIMA20130815005Charger · inoperativeEMERGENCY LIGHT BATTERY CHARGER DOESN'T CHARGE. REMOVED BATTERY CHARGER.SDR CHQA20130815314Valve · leakingCREW REPORTED DURING CLIMB, FUEL REPORTED TO BE LEAKING FROM LEFT WING. VERIFIED VAPOR COMING FROM THE LT WING AND RETURNED TO FIELD, LANDED WITHOUT INCIDENT. MX REPLACED THE FUEL TANK VALVE AT THE LT WING RIB 19. OPS CHECKED GOOD WITH NO LEAKS NOTED.SDR SIMA20130815003Lamp · inoperativeINTERIOR EMERGENCY LIGHT OVER RT WING DOOR INOPERATIVE. R & R BULB IAW MM 33-50-07, OPS CHECKED GOOD IAW MM 33-50-00.SDR SIMA20130814018Shear Tie · corrodedCORROSION ON SHEAR TIE 65 AT CARGO DOOR CUTOUT BETWEEN 16L-18L. REPAIRED SHEAR TIE FRAME 65 IAW AEA EO EM-53MR-1129, PART A.SDR SIMA20130814015Liner · out of positionRT EMERGENCY EXIT HARD TO OPEN. REMOVED AFT UPPER SCREW OF RT EMERGENCY EXIT LINING, REPOSITIONED LINING, AND REINSTALLED AFT UPPER SCREW OF RT EMERGENCY EXIT LINING IAW AMM 25-23-03.SDR SIMA20130814017Lens · crackedSERVICE DOOR EMERGENCY LIGHT LENS CRACKED. R & R LENS IAW AMM 33-50-10, OPS CHECKED GOOD IAW AMM 33-50-00.SDR SIMA20130814016Bulb · inoperativeSERVICE DOOR BOTTOM EMERGENCY LIGHT INOPERATIVE. R & R BULB IAW AMM 33-50-10. OPS CHECKED GOOD IAW AMM 33-50-00.SDR SIMA20130814014Holder · malfunctionedLIGHT STRIP NR 2 & NR 3 INOPERATIVE. REMOVED BATTERY HOLDER ASSY.SDR SIMA20130814013Battery Pack · inoperativeEMERGENCY LIGHT NR 2 & 3 INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY BATTERY.SDR SIMA20130814012Structure · crackedCRACK ON FWD AVIONICS DOOR OPENING. PERFORMED DVI IAW EO-EM-53MR-2092 PTB. NO FURTHER DAMAGE NOTED.SDR SIMA20130814008Lamp · inoperativeRIGHT AFT OVERWING EMERGENCY LIGHT INOPERATIVE. R & R LAMP IAW AMM 33-50-10. OPS CHECKED GOOD.SDR SIMA20130814010Screw · missingCREW REPORTED EMERGENCY FLASHLIGHT ASSY ABOVE F/A CHAIR WAS DETACHED FROM THE WALL. INSTALLED MISSING SCREW IN FLASHLIGHT ASSEMBLY. IAW AMM 20-00-00. ACFT RETURNED TO SERVICE.SDR SIMA20130814009Inverter · inoperativeEMERGENCY EXIT SIGN BEHIND GALLEY AT PAX SEAT 3 INOPERTIVE. R & R NR 3 INVERTER IAW AMM 33-50-11. OPS CHECKED GOOD.SDR SIMA20130814004Roller · lack of lubeF/A REPORTS PASSENGER DOOR IS HARD TO OPEN. LUBRICATED FRAME ROLLERS IAW AMM 53-21-02, OPS CHECK GOOD.
Back to Embraer EMB-145LR