Embraer EMB-145LR
Service difficulty reports · 36,875
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'EMB145LR' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR C2XA01TY033Skin · damagedTYS DURING A SCHEDULE INSPECTION THE LEFT HAND OVERWING EMERGENCY EXIT DOOR, INNER SKIN BY WINDOW WAS FOUND TO BE DAMAGED. MAINTENANCE REPAIRED SKIN BY BLENDING IAW EMB GST-0720/01 AND EMB-145 CPM 51-21-03,04,06. REPAIR WAS SATISFACTORY, AIRCRAFT WILL BE RESDR C2XA01TY032Floorbeam · corrodedTYS DURING A SCHEDULED INSPECTION THE SUPPORT STRUCTURE FOR THE LEFT HAND OMEGA BEAM WAS FOUND TO BE CORRODED. MAINTENANCE REPAIRED SUPPORT STRUCTURE BY INSTALLING DOUBLER IAW EMB-145 SRM 53-21-10 AND 53-40-02. REPAIR WAS SATISFACTORY, AIRCRAFT WILL BE RELESDR C2XA01IA148Nozzle · defectiveIAH - FLIGHT 3937, THE CREW REPORTED A FUEL SMELL IN THE COCKPIT. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE REMOVED AND REPLACED THE NUMBER ONE ENGINE FUEL NOZZLES, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR RAIA00103005Control Handle · failed7626-XNA- DURING TAXI OUT NOSE WHEEL STEERING FAILED. MAINTENANCE REMOVED AND REPLACED THE NOSE WHEEL STEERING CONTROL KNOB IAW EMB145 MAINTENANCE MANUAL.SDR C2XA01TY029Light · inoperativeTYS DURING A SCHEDULED INSPECTION THE FORWARD RIGHT HAND EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE FORWARD RIGHT HAND EMERGENCY EXIT LIGHT ASSEMBLY IAW EMB-145 MM 33-50-10. OPERATIONAL CHECKS WERE SATISFACTORY, ASDR C2XA01TY031Flight Recorder · failedTYS DURING A SCHEDULE INSPECTION THE FLIGHT DATA RECORDER FAILED FUNCTIONAL CHECKS, REFER TO CONTINENTAL EXPRESS TASK CARD 31-31-00-720-001-A00. MAINTENANCE REMOVED AND REPLACED THE FLIGHT DATA RECORDER IAW EMB-145 MM 31-31-01, OPERATIONAL CHECKS WERE SATISFSDR C2XA01TY028Light · inoperativeTYS DURING A SCHEDULED INSPECTION THE LEFT HAND OVERWING EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE LEFT HAND OVERWING EMERGENCY EXIT LIGHT BULB IAW EMB-145 MM 33-50-10. OPERATIONAL CHECKS WERE SATISFACTORY, AIRCSDR C2XA01TY030Heat Shield · gougedTYS DURING A SCHEDULED INSPECTION THE APU FIREWALL HEAT BLANKET WAS FOUND GOUGED AT THE BLEED VALVE MOUNT BRACKET. MAINTENANCE REMOVED AND REPLACED THE APU FIREWALL HEAT BLANKET IAW EMB-145 SB 145-53-0004. REPAIR WAS SATISFACTORY, AIRCRAFT WILL BE RELEASED SDR SIMA0621Seal · leakingDFW - FLT 3593 - DURING CRUISE FLIGHT, CREW REPORTED NR 2 BLEED LEAK. AIRCRAFT WAS RETURNED TO DFW. MAINTENANCE REPLACED THE BLEED DUCT SEALS. OPERATIONAL CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR SIMA200106102Windshield · crackedHRL - FLT 3724 - ON CLIMB-OUT, CREW NOTED SPARKS CAME FROM FIRST OFFICERS WINDSHIELD SIDE AREA THEY THEN TURNED WINDSHIELD HEAT OFF. AT THAT TIME THE WINDSHIELD CRACKED ALL OVER, SO THE CREW COMPLETED A EMERGENCY LANDING SAFELY. MAINTENANCE REMOVED AND REPLASDR SIMA200106101Control Unit · failedORD - FLT 4406 - DURING CLIMB-OUT, CREW NOTED ON EICAS PITCH TRIM 1 FAIL. NOTE YOKE SWITCHES DID NOT WORK BUT THE BACK UP TRIM DID. AIRCRAFT RETURNED TO ORD SAFELY. NO FURTHER INCIDENTS WERE REPORTED. MAINTENANCE REMOVED AND REPLACED HSCU IAW EMB MM. OPERSDR C2XA01BT030Tube · faultyEWR - FLT 3811 - CREW REPORTED NR 1 BLEED VALVE LIGHT AND LOST NR 1 ENGINE SHORTLY AFTER TAKEOFF. AIRCRAFT AIR RETURNED TO EWR SAFELY. MAINTENANCE TROUBLESHOT NR 1 ENGINE SHUTDOWN AND REMOVED AND REPLACED NR 1 ENGINE 9TH STAGE CHECK VALVE AND BLEED AIR TUBE.SDR C2XA01IA143Fan · inoperativeEWR - FLIGHT 4148, THE CREW REPORTED THAT DURING THE IN-FLIGHT PORTION OF THE ICE TEST THE CABIN BEGAN TO FILL WITH SMOKE AND A STRONG ODOR. THE AIRCRAFT LANDED AT EWR WITHOUT INCIDENT WHERE MAINTENANCE PLACED THE NUMBER TWO RECIRCULATION FAN ON MEL 21-24-01 SDR C2XA01IA131Unknown · odorIAH - FLIGHT 4205, THE CREW REPORTED A STRONG ODOR IN THE COCKPIT AND CABIN. MAINTENANCE PERFORMED OPERATIONAL CHECKS ON THE AIR CONDITIONING SYSTEM WITH NO DEFECTS NOTED, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA01IA128Smoke · detectedCAE - FLIGHT 4205, THE CREW REPORTED SMOKE IN THE CABIN, THE AIRCRAFT DIVERTED TO CAE WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED THE AIRCRAFT, AND OPERATIONALLY CHECKED THE AIR CONDITIONING SYSTEM WITH NO DEFECTS NOTED. THE AIRCRAFT WAS THEN APPSDR C2XA01IA126Unknown · odorIAH - FLIGHT 4175, THE CREW REPORTED THAT WITH DEICING SYSTEM ON THERE WAS A STRONG ODOR LIKE BURNING PAPER IN THE COCKPIT AND CABIN THAT SUBSIDED DURING FLIGHT. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE PERFORMED OPERATIONAL TESTS OF THE SDR C2XA01CL033Battery Pack · dischargedCLE FLIGHT 3901 THE CREW REPORTED THE AFT EMERGENCY LIGHTS WERE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE NR 4 EMERGENCY LIGHT BATTERY PACK. OPERATIONAL CHECKS WERE GOOD. THE AIRCRAFT WAS RELEASED FOR SERVICE.SDR C2XA01IA130Compressor · contaminatedIAH - FLIGHT 375, THE CREW REPORTED A STRONG ODOR COMING FROM THE NR 1 PACK WHEN SUPPLIED BY ENGINE BLEED AIR. MAINTENANCE INSPECTED THE AIRCRAFT AND DETERMINED THAT THE ODOR WAS CAUSED BY RESIDUAL FLUID FROM THE PREVIOUS NIGHT COMPRESSOR WASH, AND THE AIRCRASDR C2XA01CL031Roller · lack of lubeEWR FLIGHT 4258 THE CREW REPORTED THE FORWARD DOOR IS VERY DIFFICULT TO OPEN. MAINTENANCE INSPECTED AND LUBED THE DOOR ROLLERS. OPERATIONAL CHECKS WERE GOOD. THE AIRCRAFT WAS RELEASED FOR SERVICE.SDR C2XA01TY026Support Bracket · chafedTYS - DURING A SCHEDULED 1C INSPECTION, THE LEFT ENGINE LOWER COWLING CHAFFED AT EDGE SUPPORT AFT OF REAR HINGE. MAINTENANCE BLENDED AREA AND INSTALLED AN L SHAPED SUPPORT OVER THE AFFECTED AREA IAW EMB RED GST 0519/01. PROCEDURES WERE SATISFACTORY. AIRCRAFSDR C2XA01IA115Apu · malfunctionedIAH - FLIGHT 3781, THE CREW REPORTED A VERY STRONG FUEL SMELL IMMEDIATELY AFTER STARTING THE APU IN FLIGHT. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE OPERATIONALLY CHECKED THE APU WITH NO DEFECTS NOTED, AND THE AIRCRAFT WAS APPROVED FOR RESDR RAIA00102003Wheel · vibratesBOS-5272- DURING TAXI NOSE WHEEL VIBRATES AND GRINDS. WHILE STEERING, NOSE GEAR MAKES A GRINDING METAL TO METAL NOISE AND COULD BE FELT THROUGH RUDDER PEDALS AND TILLER. MAINTENANCE REMOVED AND REPLACED BOTH NOSE LANDING GEAR WHEEL/TIRE ASSEMBLIES IAW EMB145SDR SIMA200104601Heater · failedORD - FLT 4114 - IN CRUISE WINDSHIELD 1 HEAT FAILED. RETURN TO ORD FOR MAINTENANCE REPAIR. MAINTENANCE COMPLIED WITH ENGINEERING ORDER EM 3000-018, WINDSHIELD HEATING IMPROVEMENT. OPS CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR C2XA01CL027Strut · lowEWR FLIGHT 4036 THE CREW REPORTED A LANDING GEAR AIR/GROUND FAIL MESSAGE ALONG WITH A THRUST REVERSER 1/2 DISAGREE. THE AIRCRAFT RETURNED TO EWR AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTED AND SERVICED THE NOSE LANDING GEAR SHOCK ABSORBER. OSDR C2XA01IA091Door · malfunctionedIAH - FLIGHT 4240, THE CREW REPORTED THAT THE NOSE LANDING GEAR DOORS OPENED IN FLIGHT. THE AIRCRAFT RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE PERFORMED AN OPERATIONAL CHECK OF THE LANDING GEAR WITH NO DEFECTS NOTED, AND THE AIRCRAFT WAS SDR C2XA01TY024Floor Support · gougedTYS - DURING A SCHEDULED 1C INSPECTIN, THE OMEGA BEAM TOP CAP BETWEEN FRAMES 19 AND 23, STRINGERS 21E AND 20R WAS FOUND TO BE GOUGED. MAINTENANCE REMOVED AND REPLACED OMEGA BEAM TOP CAP IAW EMB-145-SRM 51-40-02. REPAIR PROCEDURES WERE SATISFACTORY, AIRCRAFT SDR C2XA01TY025Frame · gougedTYS - DURING A SCHEDULED 1C INSPECTION, A GOUGE WAS FOUND ON FRAME 63 IN CARGO BAY, RIGHT PYLON ATTACHMENT POINT. MAINTENANCE BLENDED GOUGE AND PERFORMED NDT INSPECTION IAW EMB REF GST 0467/01. ALODINE AND PRIMED AREA IAW EMB CPM 51-21-31 AND 04. REPAIR PROSDR C2XA01IA089Switch · malfunctionedIAH - FLIGHT 4027, THE CREW REPORTED THAT THE EMERGENCY LIGHTS FLASHED INTERMITTENTLY DURING FLIGHT. MAINTENANCE RESET THE FLIGHT ATTENDANTS EMERGENCY LIGHT SWITCH, OPERATIONALLY CHECKED THE EMERGENCY LIGHTS WITH NO DEFECTS NOTED. AIRCRAFT WAS APPROVED FOR RSDR SIMA0432Skin · gougedSAW - DURING PS-2 INSPECTION MAINTENANCE REPAIRED TDMI 706530052. GOUGE IN LEFT CENTER FUSELAGE BETWEEN FRAMES 16 AND 20 STRINGERS 15 AND 16. MAINTENANCE REPAIRED THE GOUGE IAW EO EB-53MR-012. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR C2XA01BT021Fuel Line · looseSTL/EWR - FLT 4271 - CREW REPORTED ''STRONG SMELL OF FUEL AFTER STARTING THE APU IN FLIGHT''. MAINTENANCE CONTROL MEL''D AIRCRAFT PER MEL 49-00-00 PLACARD PLACARD NR 009259. AIRCRAFT RETURNED TO EWR. MAINTENANCE SECURED FUEL LINE AT FUEL FILTER, AND GROUND SDR C2XA01TY019Strap · damagedTYS - DURING A SCHEDULED 1C INSPECTION, THE LEFT LOWER COWLING AFT FASTENER STRUCTURE HAS A TEAR IN THE METAL. MAINTENANCE REMOVED AND REPLACED STRAP IAW EMB 145 MM 51-40-02. FABRICATED NEW STRAP IAW EMB REF GST 0438/01. PROCEDURES WERE SATISFACTORY. AIRCRSDR C2XA01TY020Attach Fitting · gougedTYS - DURING A SCHEDULED 1C INSPECTION, THE RIGHT AILERON INBOARD ATTACH BRACKET WAS FOUND TO BE GOUGED. MAINTENANCE BLENDED AND DYE PENETRANT THE ATTACH BRACKET IAW EMB REF GST 0421/01, ALODINED AND PRIMED AREA IAW EMB 145 CMP 51-21-03, 51-21-04 AND 51-21-06SDR C2XA01TY023Hinge · gougedTYS - DURING A SCHEDUELD 1C INSPECTION, A GOUGE WAS FOUND IN THE PASSENGER DOOR FRAME LOWER HINGE. MAINTENANCE BLENDED GOUGE, DYE-PENNED IAW EMB 145 REF GST 0422/01, RESTORED THE REWORKED AREA IAW EMB 145-CPM-51-21-03, -04 AND -06. NO FURTHER ACTION REQUIREDSDR C2XA01TY022Hinge · gougedTYS - DURING A SCHEDULED 1C INSPECTION, A GOUGE WAS FOUND IN THE PASSENGER ENTRY DOOR FRAME UPPER HINGE. MAINTENANCE BLENDED GOUGE, DYE-PENNED IAW EMB 145 REF GS 0422/01, RESTORED THE REWORKED AREA IAW EMB 145 CPM 51-21-03, -04 AND -06. NO FURTHER ACTION REQSDR C2XA01TY021Strut · gougedTYS - DURING A SCHEDULED 1C INSPECTION, SEVERAL GOUGES WERE FOUND IN THE NOSE LANDING GEAR STRUT ASSY, MAINTENANCE BLENDED GOUGES, DYE-PENNED IAW EMB 145 REF GST 0401/01, RESTORED THE REWORKED AREA IAW EMB 145 CPM 51-21-03,-04 AND -06. NO FURTHER ACTION REQUISDR C2XA01TY017Firewall · gougedTYS - DURING A SCHEDULED 1C INSPECTION, A GOUGE IN THE APU FIREWALL BELOW UPPER APU MOUNT. MAINTENANCE BLENDED AND DYE-PENNED, AND NO DEFECTS NOTED IAW EMB 145 REF GST 0433/01. PROCEDURES WERE SATISFACTORY. AIRCRAFT WILL BE RELEASED FOR SERVICE UPON COMPLETSDR C2XA01TY016Frame · gougedTYS - DURING A SCHEDULED 1C INSPECTION, A GOUGE WAS FOUND IN FRAME 70 BETWEEN BLEED LINE AND CARGO FLOOR. MAINTENANCE BLENDED GOUGE, DYE PENETRANT INSPECTED, ALODINED AND PRIMED AREA IAW EMB REF GST 0427/01, 145-NDI MANUAL 53-31-00, CMP 51-21-03 AND 51-21-05.SDR C2XA01TY015Beam · corrodedTYS - DURING A SCHEDULED 1C INSPECTION, RIGHT OMEGA BEAM AT FRAME 20 BETWEEN STRINGERS 21R AND 20R WAS FOUND TO HAVE CORROSION. MAINTENANCE BLENDED OMEGA BEAM, PERFORMED DYE PENETRANT INSPECTION. ALODINED AND PRIMED IAW EMB REF GST 0409/01, EMB 145 NDI MM 53SDR C2XA01TY018Fire Loop · chafedTYS - DURING A SCHEDULED 1C INSPECTION, THE APU FIRE LOOP WAS FOUND CHAFED. MAINTENANCE REMVOED AND REPLACED THE FIRE LOOP IAW EMB 145 MM 26-12-01. PROCEDURES WERE SATISFACTORY, AIRCRAFT WILL BE RELEASED FOR SERVICE UPON COMPLETION OF C-CHECK. (M)SDR C2XA01IA080Unknown · odorIAH - FLIGHT 3938, THE CREW REPORTED AN ELECTRIC ODOR IN THE CABIN AND COCKPIT DURING TAXI. THE AIRCRAFT RETURNED TO THE GATE WHERE MAINTENANCE INSPECTED THE AIRCRAFT, FOUND NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR 20010525SG001Duct · leakingCMH - FLT 5346 - CREW RETURNED TO FIELD DUE TO BAGGAGE SMOKE INDICATION FOLLOWED BY ENGINE TWO BLEED LEAK. MAINTENANCE REMOVED AND REPLACED THE NR 2 FUSELAGE THROUGH PYLON BLEED LINE AND THE CARGO DUCT ASSEMBLY. OPS CHECK WAS GOOD, FIRE BOTTLES WERE REPLACED SDR SIMA200104103Line · leakingCMH - FLT 5346 - CREW RETURNED TO FIELD DUE TO BAGGAGE SMOKE INDICATION FOLLOWED BY ENGINE TWO BLEED LEAK. MAINTENANCE REMOVED AND REPLACED THE NR 2 FUSELAGE THROUGH PYLON BLEED LINE AND THE CARGO DUCT ASSEMBLY. OPS CHECK WAS GOOD, FIRE BOTTLES WERE REPLACED SDR MASA02018Smoke Detector · malfunctionedFLT 5808 - RETURNED TO THE FIELD AFTER THE LAV SMOKE DETECTOR WENT OFF INFLIGHT. THE F/A INSPECTED THE LAVATORY AND FOUND NO SMOKE OR EVIDENCE OF FIRE. MAINTENANCE PERFORMED AN INSPECTION IAW WITH THE MAINTENANCE PROCEDURES. MAINTENANCE MEL''D THE DISCREPANSDR SIMA200003901Smoke Detector · malfunctionedORD - FLT 4401 - DURING CLIMB, CREW REPORTED THE LAV SMOKE CAUTION LIGHT ILLUMINATED. AIRCRAFT RETURNED TO ORD, LIGHT EXTINGUISHED DURING APPROACH. MAINTENANCE COULD NOT DUPLICATE DISCREPANCY. OPS CHECK WAS GOOD AND AIRCRAFT WAS RELEASED FOR FLIGHT. NEXT FSDR C2XA01BT013Fire Loop · failedLGA - FLT 4161 - CREW REPORTED ''E1 FIRE DETECTOR FAIL'', LGA MAINTENANCE REMVOED AND REPLACED NR 1 ENGINE FIRE LOOP IAW EMB145 MM 26-11-01, OPS CHECKED GOOD. (M)SDR C2XA01IA077A/C Pack · failedIAH - FLIGHT 3761, THE CREW REPORTED A STRONG ODOR IN THE CABIN WITH THE NUMBER ONE PACK RUNNING. THE AIRCRAFT LANDED AT OAH WITHOUT INCIDENT WHERE MAINTENANCE PLACED THE NUMBER ON PACK ON MEL 21-51-00 CAT-C CONTROL NUMBER 00962, AND THE AIRCRAFT WAS APPROVEDSDR C2XA01BT015Warning System · activatedRIC - FLT 3669 - CREW REPORTED ''RIGHT AFTER V1 ON GROUND ON TAKEOFF, RECEIVED MASTER WARNING (NO EICAS MESSAGES) PITCH TRIM HAD RUN FROM 7 UNITS UP TO 2 UNITS UP WITHIN 2 SECONDS. AIRCRAFT COULD NOT BE TRIMMED AGAIN UNTIL APPROXIMATELY 500 FEET, 160 KNOTS. NSDR C2XA01BT007Fire Loop · faultyYHZ - CREW REPORTED E2 FIRE DETECTOR FAILED. DISPATCHED MAINTENANCE TO HALIFAX. TROUBLESHOT PROBLEM AND FOUND A BAD NR 2 ENGINE FIRE LOOP. MAINTENANCE REMOVED AND REPLACED NR 2 ENGINE PYLON FIRE LOOP. OPS CHECKED GOOD IAW EMB 145 AMM, JIC 26-11-02. AIRCRASDR SIMA200103601Actuator · malfunctionedSGF - FLT 3560 - ON TAKEOFF ROLL, HAD TR1 DISAGREE, ABORTED TAKEOFF AND RETURNED TO GATE. ENGINE 1 THRUST REVERSER PUT ON MEL AT THIS TIME. MAINTENANCE ADJUSTED UPPER AND LOWER T/R ACTUATORS ON NR 1 ENGINE IAW EMB MM. OPS CHECK WAS GOOD AND AIRCRAFT WAS RETSDR SIMA0364Duct · damagedXNA - FLT 3721 - ON TOUCHDOWN, THE CREW REPORTED THE NR 2 ENGINE FIRE WARNING INDICATION. THE CREW PULLED THE FIRE BOTTLE HANDLES AND RELEASED THE AGENT. AFTER THE AIRCRAFT WAS PARKED, THE CREW AND CRASH FIRE AND RESCUE WALKED AROUND AND FOUND NO VISIBLE EVI
Back to Embraer EMB-145LR