Embraer EMB-145XR

Service difficulty reports · 9,191

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'EMB145XR'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR JJBA20260130045Skin · dentedFUSELAGE EXTERNAL MID SKIN AT FR 8, LH, HAS DAMAGE. PERFORMED RECONTOUR TO DENTED AREA BTW FR 8 - 9, AT STGR 17LDec 6, 2025 · N14168 · Emb EMB145XR · Fuselage Main, Plate/SkinSDR JJBA20260130054Gusset · corrodedCORROSION ON THE CENTERLINE GUSSET FRAMES 59-60. REMOVED AND REPLACED WITH NEW FROM STOCK CENTERLINE GUSSET FRAMES 59-60Dec 5, 2025 · N14168 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20260130053Support · corrodedCORROSION ON THE RT SILL AT FRAME 57. REMOVED RH SILL FROM FRAME 53 TO FRAME 59, INSTALLED NEW FROM STOCKDec 5, 2025 · N14168 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20260130050Frame · corrodedCORRODED FRAME 22 STR 17R. REMOVED AND INSTALLED NEW FROM STOCK GUSSET AT FRAME 22 STR 17RDec 4, 2025 · N14168 · Emb EMB145XR · Fuselage Main, FrameSDR JJBA20260130047Skin · dentedFUSELAGE EXTERNAL SKIN AT FR 25, RH, STR 20R, HAS PROTRUSION. RECONTOURED PROTRUSION ON FUSELAGE EXTERNAL SKIN AT FR 25, RH, STR 20RDec 4, 2025 · N14168 · Emb EMB145XR · Fuselage Main, Plate/SkinSDR JJBA20251208018Floor Support · corrodedRIGHT OMEGA BEAM BTW FR 59-61 CORRODED. 2 REPAIR DOUBLERS ON CENTER FUSE IV RT OMEGA BEAM, ON UPPER SURFACE BTW FR 59-60 AND BTW FR 60-61 CUTOUTDec 2, 2025 · N14158 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20251204004Battery Pack · inoperativeMULTIPLE EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BPS NR 3. OPS CHECK SAT.Dec 2, 2025 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20251204003Lamp · inoperativeRH LATERAL WING-TO-FUSELAGE FAIRING EMERGENCY LIGHT INOPERATIVE. RH SIDE CENTER FAIRING EXTERNAL EMERGENCY LIGHT ACCESS PANEL HAS 4 STRIPPED SCREWS. REMOVED AND REPLACED RH LATERAL WTF FAIRING EMERGENCY LIGHT LAMP. OPS CHECK FAIL. FOUND A PIN MISSING ON ELECTRDec 1, 2025 · N23139 · Emb EMB145XR · Emergency LightingSDR JJBA20251208016Floor Support · crackedCENTER FUSE II, LEFT OMEGA BEAM CRACKED AT FRAME 33. CF II, REPAIR DOUBLER ON LT OMEGA BEAM INBD VERT FLANGE AT FR 33.Nov 28, 2025 · N14158 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20251204002Floor Support · crackedCENTER FUSELAGE II, LT OMEGA BEAM CRACKED AT FRAME 34. REPAIR DOUBLER ON LT OMEGA BEAM INBD VERT FLANGE AT FR 34.Nov 28, 2025 · N14158 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20251204012Door · crackedON LH TR UPPER DOOR, FWD INBD EDGE FOUND CRACKED. ON LH TR UPPER DOOR, FWD INBD EDGE OF KICKER PLATE, FASTENERS REMOVED. ON LH TR UPPER DOOR, FWD IB KIKER PLATE REMOVED AND REPLACED.Nov 27, 2025 · N14158 · Emb EMB145XR · Engine Thrust ReverserSDR JJBA20251208019Floor Support · crackedCENTER OMEGA BEAM CRACKED AT FRAME 28. REPAIR DOUBLER INSTALLED ON CTR FUSELAGE II CTR OMEGA BEAM, AT FR 28 INBD VERTICAL FLANGE.Nov 26, 2025 · N14158 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20251204014Floor Support · crackedCENTER FUSE II, LH OMEGA BEAM CRACKED AT FRAME 35. CENTER FUSE II, LH OMEGA BEAM AT FRAME 35 CUT-OUT PERFORMED AND REPAIRED.Nov 26, 2025 · N14158 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20251204013Rib · crackedRH ENGINE UPPER COWLING, FWD RIB AT XN810 FOUND CRACKED. ON RH ENGINE UPPER COWLING, FWD RIB AT XN810 REMOVED AND REPLACED.Nov 26, 2025 · N14158 · Emb EMB145XR · Nacelle/Pylon, Frame/Spar/RibSDR JJBA20251204011Spar Cap · corrodedLT AND RT WING SPAR II CAP SURFACE TO BE CLEAN AND REPROTECTED AT LOCATION OF AILERON LOWER SHROUD. AT LT & RT WING SPAR II CAP SURFACE FOUND CORRODED, LH WING SPAR II CAP SURFACE CORRODED OUT OF LIMIT AND RH WING SPAR II CAP SURFACE BLENDED WITHIN LIMIT. AT TNov 26, 2025 · N14158 · Emb EMB145XR · Wing SparSDR JJBA20251125110Battery Pack · inoperativeEMERGENCY LIGHT #2 BPS INOPERATIVE. REMOVED AND REPLACED #2 BPS. OPS CHECK GOOD.Nov 25, 2025 · N14125 · Emb EMB145XR · Emergency LightingSDR JJBA20251209025Seat Track · corrodedRIGHT INBD SEAT TRACK NR 2, 4, 6, 10, 18, 20, 26, 28 FOUND CORRODED. RT INBD SEAT TRACK NR 2, 4, 6, 10, 18, 20, 26, 28 BLENDED. RT INBD SEAT TRACK NR 2, 4, 10, 18, 20, 26, 28 REPROTECTED. AT RT INBD SEAT TRACK NR 6 REMOVED AND INSTALLED.Nov 24, 2025 · N14158 · Emb EMB145XR · Fuselage, Seat/Cargo Attach FittingsSDR JJBA20251209024Seat Track · corrodedLEFT INBD SEAT TRACK NR 2, 4, 5, 6, 7, 15, 20, 21, 29, 33 FOUND CORRODED. AT LT INBD SEAT TRACK NR 2, 4, 5, 6, 7, 15, 20, 21, 29, AND 33 REMOVED FOR INSPECTION. SEAT TRACKS BLENDED OUT OF LIMITS. AT LT INBD SEAT TRACK NR 15 NEW SEAT TRACK INSTALLED.Nov 24, 2025 · N14158 · Emb EMB145XR · Fuselage, Seat/Cargo Attach FittingsSDR JJBA20251125109Fuel Sys · false indicationFUEL WING 1 INDICATED ZERO ON DEPARTURE FOLLOWED BY FUEL LOW LEVEL 1/2 EICAS MESSAGE. INSPECTED AND FOUND REFUEL SWITCH IN THE OPEN POSITION ON REFUEL PANEL. CLOSED REFUEL SWITCH. NO FAULTS ON REPEATER. FUEL INDICATIONS OPS CHECK OKAY AT THIS TIME. NO FAULTS NNov 22, 2025 · N12201 · Emb EMB145XR · Fuel Indicating SystemSDR JJBA20251125108Control Unit · inoperativePITCH TRIM INOPERATIVE MESSAGE AT V1. REMOVED AND REPLACED HORIZONTAL STAB CONTROL UNIT. OPS/INDICATION CHECK SAT.Nov 22, 2025 · N27190 · Emb EMB145XR · Elevator Control SystemSDR JJBA20251204009Floor Support · damagedCENTER OMEGA BEAM BETWEEN 58-63 DAMAGED DURING REPAIR. CTR OMEGA BEAM BTW 58-63 FR REPAIRED.Nov 20, 2025 · N14158 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20251120094Floorbeam · crackedMID FLOOR SUPPORT AT FRAME 20 HAS CRACK. REMOVED AND REPLACED MID FLOOR ANGLE AND ATTACHED SUPPORT AT FR20.Nov 20, 2025 · N12195 · Emb EMB145XR · Fuselage Main, Floor BeamSDR JJBA20251208020Floorbeam · corrodedCENTER FUSE I, CENTER CROSSBEAM AT FRAME 20, LOWER AND UPPER SURFACE CORRODED. CENTER FUSE I CENTER CROSSBEAM AT FR20 BLENDED OUT OF LIMITS. CENTER FUSE I, CENTER CROSSBEAM AT FRAME 20 MADE REPAIR PART FABRICATED. CENTER FUSE I, CENTER CROSSBEAM AT FRAME 20 MANov 19, 2025 · N14158 · Emb EMB145XR · Fuselage Main, Floor BeamSDR JJBA20251125104Gusset · corrodedCENTER GUSSET BTW FR 59-61 FOUND CORRODED. CENTER GUSSET BTW FR 59-61 BLENDED AND FOUND OUT OF LIMIT. CENTER GUSSET BTW FR 59-61 REMOVED AND REPLACED.Nov 19, 2025 · N14158 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20251209023Floor Support · corrodedCENTER OMEGA BEAM AT FR59 FOUND CORRODED. CF4, CENTER OMEGA BEAM AT FR59 BLENDED AND FOUND OUT OF LIMIT. CF4, CENTER OMEGA BEAM AT FR59 CUTOUT PERFORMED. CF4 CENTER OMEGA BEAM AT FR59, OMEGA BEAM DAMAGED DURING REPAIR. CENTER OMEGA BEAM AT FR59 REPAIRED.Nov 18, 2025 · N14158 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20251119104Tee Angle · corrodedAT FRAME 61 BETWEEN LT SILL & LT OMEGA BEAM, TEE PROFILE. TEE PROFILE WAS REPLACED.Nov 17, 2025 · N14158 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20251117102Lamp · inoperativeRIGHT EMERGENCY LIGHT OF FORWARD LOWER FAIRING INOPERATIVE. REMOVED AND REPLACED RT EMERGENCY LIGHT LAMP. OPS CHECK SAT.Nov 16, 2025 · N16170 · Emb EMB145XR · Emergency LightingSDR JJBA20251117103Oil System · leakingSMOKE ODOR IN COCKPIT & CABIN DURING CRUISE AT FLT LEVEL 220. OPS BOTH PACKS WITH NO FAULTS. FOUND BOTH MUFFLERS TO HAVE TEARS & EVIDENCE OF BURNS. R & R BOTH RECIRC MUFFLERS. PERFORMED OPS CHECK OF PACK SYS. FAULT PERSISTS, RAN PACK 1 & 2 ON BOTH APU & ENGS INov 15, 2025 · N11165 · Emb EMB145XR · Turbine Engine Oil SystemSDR JJBA20251114101Oxygen Bottle · inoperativeCREW OXYGEN PRESSURE IS AT ZERO PSI. REMOVED AND REPLACED CREW OXYGEN CYLINDER. LEAK CHECK SATNov 14, 2025 · N21154 · Emb EMB145XR · Crew Oxygen SystemSDR JJBA20251204010Doubler · corrodedRIGHT FR61 AT FLOOR LEVEL FRAME DOUBLER FOUND CORRODED. RT FR61 AT FLOOR LEVEL, FRAME DOUBLER BLENDED OUT OF LIMIT. RH FR61 AT FLOOR LEVEL, FRAME DOUBLER REPLACED WITH NEW PARTNov 13, 2025 · N14158 · Emb EMB145XR · Fuselage Main, FrameSDR JJBA20251204007Support · corrodedCENTER FUSE I, LT SILL BTW FRAME 19-23 FOUND CORRODED. LT SILL BTW FRAME 19-23 REPLACED WITH NEW.Nov 12, 2025 · N14158 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20251204005Doubler · corrodedLH FR 61 AT FLOOR LEVEL, FRAME DOUBLER CORRODED. LT FR 61 AT FLOOR LEVEL, FRAME DOUBLER IS OUT OF LIMIT. LT FR 61 AT FLOOR LEVEL, FRAME DOUBLER REPLACED.Nov 12, 2025 · N14158 · Emb EMB145XR · Fuselage Main, FrameSDR JJBA20251204001Floor Support · corrodedLEFT GUSSET BTW FRAME 19-23 FOUND CORRODED. LT GUSSET BTW FR 19-23, GUSSET REMOVED AND REPLACED.Nov 12, 2025 · N14158 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20251125105Floor Support · corrodedRH SILL #6 CORRODED BTW FR 53-59. BTW FR 53-54 RH SILL #6 BLENDED OUT OF LIMITS. RH SILL #6 BTW FR 53-39 REMOVED AND REPLACEDNov 12, 2025 · N14158 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20251112063Elec Connector · disconnectedBOTH EMERGENCY LIGHTS NEAR RH WING ROOT IS INOPERATIVE. RECONNECTED CANNON PLUGS OF BOTH RH WING-TO-FUSELAGE FAIRING EMERGENCY LIGHTS.Nov 12, 2025 · N21154 · Emb EMB145XR · Light System WiringSDR JJBA20251125095Window Frame · corrodedFOUND CORROSION AROUND MULTIPLE SCREW HOLES BY THE RH DV WINDOW FRAME. RECEIVED NEW OUTER FRAME HALF FOR RH DV WINDOW, LOCATED AND DRILLED NEW HALF FOR INSULATION.Nov 11, 2025 · N12195 · Emb EMB145XR · Fuselage Main, StructureSDR JJBA20251120089Rib · damagedRIGHT HAND MIDDLE LEADING EDGE DAMAGED ON REMOVAL AND HAS DAMAGE ON INBOARD EDGE. REMOVED AND REPLACED RH MIDDLE LEADING EDGE INBD RIB.Nov 10, 2025 · N12195 · Emb EMB145XR · Wing, Rib/BulkheadSDR JJBA20251111044Door · no discrepancyMCD HARD TO OPEN/CLOSE. PERFORMED GVI AND PERFORMED MULTIPLE OPS CHECK. OPS CHECK SAT. NO FURTHER DEFECTS NOTED. PRESSURIZED, PERFORMED MULTIPLE OPS CHECK OF MCD. LEAK CHECK SAT AND OPS CHECK SAT. NO DEFECTS NOTED.Nov 9, 2025 · N11191 · Emb EMB145XR · Passenger/Crew DoorsSDR JJBA20251111062Elec Connector · inoperativeLH FWD EXTERIOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BULB. NO FIX. FOUND PIN ON HOUSING BURNT (NPIS). REMOVED AND REPLACED LH EXT EMERGENCY LIGHT ASSEMBLY. NO FIX. FOUND NO VOLTAGE ON CANNON PLUG. REMOVED AND REPALCED FUSE ON #1 EMERGENCY BATTERY Nov 8, 2025 · N14168 · Emb EMB145XR · Light System WiringSDR JJBA20251120065Skin · corrodedFUSELAGE EXTERNAL LOWER SKIN LH AT FR 61, STR 18L, HAS CORROSION. COMPLIED WITH REAR FUSELAGE I - PERMANENT REINFORCING REPAIR OF SKIN AT FRAME 61 AND STRINGER 18LNov 7, 2025 · N12195 · Emb EMB145XR · Fuselage Main, Plate/SkinSDR JJBA20251120072Floorbeam · corrodedLH FLOOR BEAM LOWER IB LIP DOUBLER AT FR 22, STR 4L, HAS CORROSION. REMOVED CORRODED DOUBLER, FABRICATED AND INSTALLED NEW LH FLOOR BEAM LWR IB LIP DOUBLER AT FR22Nov 6, 2025 · N12195 · Emb EMB145XR · Fuselage Main, Floor BeamSDR JJBA20251120070Floorbeam · corrodedLH FLOOR BEAM LOWER IB LIP AT FR 20, STR 4L, HAS CORROSION. REMOVED CORRODED DOUBLER, FABRICATED AND INSTALLED NEW LH FLOOR BEAM LWR IB LIP DOUBLER AT FR20Nov 6, 2025 · N12195 · Emb EMB145XR · Fuselage Main, Floor BeamSDR JJBA20251125093Floor Support · crackedCRACK IN THE OMEGA BEAM SPLICE DOUBLER AT MOST FWD IB FASTENER HOLE AT FR 23 / STR 15L. REMOVED AND REPLACED OMEGA BEAM SPLICE DOUBLER.Nov 5, 2025 · N12195 · Emb EMB145XR · Fuselage Miscellaneous StructureSDR JJBA20251125092Access Panel · wornACCESS PANEL #412 CL SHOWS BARE METAL. RECEIVED NEW PANEL AND PAINTED.Nov 5, 2025 · N12195 · Emb EMB145XR · Fuselage Main, Plate/SkinSDR JJBA20251120097Mount · corrodedRADIO ALTIMETER (RAR 2) MOUNT HAS CORROSION/PITTING ON CONNECTOR HOLE LOWER EDGE. INSTALLED COMPLETE RADIO ALTIMETER (RAR 2) MOUNTNov 5, 2025 · N12195 · Emb EMB145XR · Ground Proximity SystemSDR JJBA20251120090Skin · corrodedRH AILERON IB SKIN HAS CORROSION. NEW RH AILERON INSTALLED.Nov 5, 2025 · N12195 · Emb EMB145XR · AileronsSDR JJBA20251120074Floorbeam · corrodedLH FLOOR BEAM LOWER IB LIP DOUBLER AT FR 23, STR 4L, HAS CORROSION. REMOVED CORRODED DOUBLER, FABRICATED AND INSTALLED NEW LH FLOOR BEAM LWR IB LIP DOUBLER AT FR23Nov 5, 2025 · N12195 · Emb EMB145XR · Fuselage Main, Floor BeamSDR JJBA20251120073Floorbeam · corrodedLH FLOOR BEAM LOWER IB LIP AT FR 22, STR 4L, HAS CORROSION. REMOVED CORRODED DOUBLER, FABRICATED AND INSTALLED NEW LH FLOOR BEAM LWR IB LIP DOUBLER AT FR22Nov 5, 2025 · N12195 · Emb EMB145XR · Fuselage Main, Floor BeamSDR JJBA20251120071Floorbeam · corrodedLH FLOOR BEAM LOWER IB LIP DOUBLER AT FR 21, STR 4L, HAS CORROSION. REMOVED CORRODED DOUBLER, FABRICATED AND INSTALLED NEW LH FLOOR BEAM LWR IB LIP DOUBLER AT FR 21Nov 5, 2025 · N12195 · Emb EMB145XR · Fuselage Main, Floor BeamSDR JJBA20251106007Battery Pack · dischargedNR 2 EMERGENCT LIGHT BATTERY PACKS NOT HOLDING CHARGE. R & R THE NR 2 BATTERY PACKS. OP CHECKED GOOD.Nov 5, 2025 · N17196 · Emb EMB145XR · Emergency Lighting
Back to Embraer EMB-145XR