Gulfstream Aerospace G-IV
Service difficulty reports · 842
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'GIV' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'GIV' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GR4D20160808005Fitting · corrodedDURING NORMAL SCHEDULED INSPECTION, FOUND CORROSION IN MOUNT BOLT BORE.SDR GR4D20160808004Fitting · corrodedTHE RT C FLAP TRACK UPPER FITTING WAS FOUND TO HAVE CORROSION IN ATTACH BORE DURING NORMAL SCHEDULED INSPECTION OF THAT AREA.SDR GR4D20160808003Fitting · corrodedDURING NORMAL SCHEDULED INSPECTION FOUND LT C-FLAP TRACK UPPER FITTING TO HAVE CORROSION IN ATTACH BORE.SDR GR4D20160808002Flap Track · corrodedDURING NORMAL SCHEDULED INSPECTION THE RT B FLAP TRACK WAS FOUND TO HAVE CORROSION IN ATTACH BOLT HOLE.SDR GR4D20160808001Flap Track · corrodedLEFT B FLAP TRACK WAS FOUND TO HAVE CORROSION IN ATTACH BORE DURING NORMAL SCHEDULED INSPECTION.SDR GR4D20160726004Fitting · corrodedRIGHT B-FLAP TRACK LOWER FITTING WAS FOUND TO HAVE CORROSION IN ATTACH BORE DURING NORMAL SCHEDULED INSPECTION.SDR GR4D20160726003Flap Track · corrodedDURING NORMAL INSPECTION FOUND LEFT HAND LOWER B TRACK FITTING FOUND CORROSION INSIDE MOUNT HOLE.SDR GR4D20160726002Flap Track · corrodedDURING NORMAL SCHEDULED INSPECTION OF THE RIGHT HAND "B" FLAP TRACK, FOUND CORROSION IN MOUNTING HOLE.SDR GR4D20160726001Fitting · corrodedDURING NORMAL SCHEDULED INSPECTION OF THE LT B-FLAP TRACK FITTINGS, FOUND CORROSION IN BORE OF ATTACH HOLES. REV GIV, MSG3, CMP 575111.SDR AOQ2016F00000Fuel Line · chafedWHILE PERFORMING FUSELAGE INTERIOR WING ATTACH INSPECTION TC 532055, FOUND FUEL MAINFOLD LINE CHAFING AGAINST APU IGNITOR, IGNITION LEAD.SDR GR4D20160720006Flap Track · corrodedRIGHT A-FLAP TRACK HAS CORROSION INSIDE BORE OF ATTACH HOLE. CORROSION WAS FOUND DURING NORMAL SCHEDULED INSPECTION OF THAT AREA, REF MSG 3, CMP 575111.SDR GR4D20160720005Flap Track · corrodedLEFT A-FLAP TRACK HAS CORROSION INSIDE BORE OF ATTACH HOLE. CORROSION WAS FOUND DURING NORMAL SCHEDULED INSPECTION OF THAT AREA, REF MSG 3, CMP 575111.SDR GR4D20160720004Fitting · corrodedTHE LOWER A FLAP TRACK FITTING ON THE RT WING HAS CORROSION INSIDE BORE OF ATTACH HOLE. CORROSION WAS FOUND DURING NORMAL SCHEDULED INSPECTION OF THAT AREA, REF MSG 3, CMP 575111.SDR GR4D20160720003Attach Fitting · corrodedTHE LOWER A-FLAP TRACK FITTING ON THE LT WING HAS CORROSION INSIDE BORE OF ATTACH HOLE. CORROSION WAS FOUND DURING NORMAL SCHEDULED INSPECTION OF THAT AREA. REF MSG 3, CMP 575111.SDR GR4D20160720002Attach Fitting · corrodedTHE UPPER A-FLAP TRACK ATTACH FITTING ON THE LT WING HAS CORROSION INSIDE BORE OF ATTACH HOLE. CORROSION WAS FOUND DURING SCHEDULED INSPECTION OF THAT AREA, REF MSG 3 CMP 575111.SDR GR4D20160720001Attach Fitting · corrodedTHE UPPER A-FLAP TRACK ATTACH FITTING ON THE LT WING HAS CORROSION INSIDE BORE OF ATTACH HOLE. CORROSION WAS FOUND DURING SCHEDULED INSPECTION OF THAT AREA, REF MSG 3, CMP 575111.SDR DXTA2016062906263Fitting · corrodedHORIZONTAL / VERTICAL STABILIZER ATTACH PIVOT FITTING HAS RUST BLEED FROM LT AND RT FITTINGS. COMPLIED WITH REPAIR OF HORIZONTAL / VERTICAL STABILIZER ATTACH PIVOT FITTINGS IAW ENGINEERING DISPOSITION TO USE DRAWING SE05455106SDR DXTA2016062906262Fitting · corrodedCORROSION FOUND AT FLAP TRACK SUPPORT FITTING BOLT HOLE ON LT FLAP TRACK FITTINGS A, B, C, D AND RT FLAP TRACK FITTINGS A, B, C, D. REQUESTED ENGINEERING DISPOSITION FOR REPAIRS. REMOVED CORROSION AND NDT AS REQUIRED. REPLACED UPPER/LOWER FITTINGS AND TRACKSSDR ZLWA20160926001Bleed Air Sys · lowDURING MAINTENANCE INVESTIGATION OF REPORTED LOW APU BLEED AIR PRESSURE DURING ENGINE START CYCLE, A DISCREPANCY BETWEEN AFM REV 49 DATED 10 DEC 2012 AND AMM REV 26 DATED SEPT 2015 FOR APU BLEED AIR PRESSURES REQUIRED FOR ENGINE START WAS DISCOVERED. AMM ENGISDR DXTA2016062406260Unknown · malfunctionedPOWER LEVERS HARD STUCK IN IDLE ON FINAL APPROACH. THRUST REVERSERS WERE DOWN AND AUTOTHROTTLES WERE OFF. VERY HARD PUSH TO GET LEVERS TO MOVE FWD. AFTERWARD LEVERS OPERATED NORMAL. PERFORMED A VISUAL INSPECTION OF THE THROTTLE QUADRANT AND ALL AUTOTHROTTLSDR GR4D20160804001Strap · corrodedHORIZONTAL STABILIZER T/E LT UPPER OVERHANG STRAPS HAVE CORROSION AROUND SEVERAL SCREW HOLES. REQUIRES MAJOR REPAIR DOCUMENTED ON FORM 8100-9.SDR DVYA201606190002Fitting · looseCOMBINED HYDRAULIC SYSTEM FLUID LOSS DUE TO FITTING BECOMING LOOSE AT FLIGHT POWER SHUTOFF VALVE. SECURED FITTING, SERVICED AND TESTED SYSTEM, SUBSEQUENT OPERATION NORMAL.SDR GR4D20160713001Channel · crackedBS 169 CHANNEL CRACKED BETWEEN MAIN ENTRANCE DOOR ACTUATOR ATTACH POINTS. APPROXIMATE LENGTH IS 0.75 INCH.SDR GR4D20160719006Hinge Fitting · corrodedLEFT ELEVATOR HINGE NR 4, ATTACHED TO HORIZONTAL STABILIZER SIDE, CORRODED INSIDE ATTACH BOLT BORE.SDR GR4D20160719005Hinge Fitting · corrodedLEFT ELEVATOR HINGE NR 3, ATTACHED TO HORIZONTAL STABILIZER SIDE, CORRODED INSIDE ATTACH BOLT BORE.SDR GR4D20160719004Hinge Fitting · corrodedLEFT ELEVATOR HINGE NR 2, HORIZONTAL STABILIZER SIDE, CORRODED INSIDE ATTACH BOLT BORE.SDR GR4D20160719003Hinge Fitting · corrodedRIGHT ELEVATOR HINGE NR 4, HORIZONTAL STABILIZER SIDE, CORRODED INSIDE ATTACH BOLT BORE.SDR GR4D20160719002Hinge Fitting · corrodedRIGHT ELEVATOR HINGE NR 3, HORIZONTAL STABILIZER SIDE, CORRODED INSIDE ATTACH BOLT BORE.SDR GR4D20160719001Hinge Fitting · corrodedRIGHT ELEVATOR HINGE NR2, HORIZONTAL STABILIZER SIDE, CORRODED INSIDE ATTACH BOLT BORE.SDR GR4D2016071900001Hinge Fitting · corrodedRIGHT ELEVATOR HINGE NR 2, HORIZONTAL STABILIZER SIDE. CORRODED INSIDE ATTACH BOLT BORE.SDR GR4D20160718003Fitting · corrodedRIGHT VERTICAL STABILIZER FITTING FOR HORIZONTAL STABILIZER ATTACHMENT BLEEDING RUST FROM PIVOT BORE.SDR GR4D20160718002Fitting · corrodedLEFT VERTICAL STABILIZER FITTING FOR HORIZONTAL STABILIZER ATTACHMENT BLEEDING RUST FROM PIVOT BEARING BORE.SDR GR4D20160718001Attach Fitting · corrodedHORIZONTAL STABILIZER PIVOT FITTING CORRODED AND BLEEDING RUST FROM LT AND RT LUG ATTACH POINTS. REQUIRES MAJOR REPAIR DOCUMENTED ON FAA FORM 8100-9.SDR 9PVA2016052600001Fuel Control · failedAFTER A NORMAL TAKEOFF, THE AUTO-THROTTLES ATTEMPTED TO REDUCE THE POWER FOR A CLIMB POWER SETTING. THE LT ENGINE RESPONDED ACCORDINGLY; THE RT ENGINE, HOWEVER, REMAINED AT FULL TAKEOFF POWER.SDR BKEA2016040400001O-Ring · damagedHYDRAULIC QUANTITY, FLIGHT SYS, LOW PRESSURE NEVER DROPPED BELOW 2500 PSI. FOUND UNION EXCESSIVELY LEAKING HYDRAULIC FLUID. ENTIRE TAIL COMPARTMENT WAS CONTAMINATED WITH HYDRAULIC FLUID. REMOVED PRESSURE TRANSMITTER FOR FURTHER INSPECTION, FOUND DAMAGED O-RSDR DXTA2016050206217Link · corrodedRIGHT FWD UPPER WING ATTACH LINK IS CORRODED TO A POINT WHERE REPLACEMENT IS NECESSARY. INSTALLED NEW RT UPPER OTBD FWD WING LINK, PN 1159BM20532-3, USING NEW ATTACHING HARDWARE IAW DWG 1159W20000.SDR DXTA201603256217Link · corrodedRIGHT FWD UPPER WING ATTACH LINK IS CORRODED TO A POINT WHERE REPLACEMENT IS NECESSARY.SDR DXTA2016031906206Pin · wornRIGHT REVERSER UNLOCK CAS MSG CLIMBING THRU 28000 FT AT 300 KT. COMPLIED WITH QRH CHECKLIST & LANDED. ACTIVATED RT THRUST REVERSER IAW CMP 780012. PERFORMED T/R UNLOCK OPERATIONAL TEST IAW MM 78-00-00, ALL SWITCHES CHECKED GOOD. DURING OPERATIONS CHECK FOUSDR DXTA2016030706203Flap Track · corrodedRIGHT FLAP TRACK SUPPORT FITTING D, CORROSION FOUND AT FLAP TRACK SUPPORT FITTING BOLT HOLE. AFTER CORROSION WAS REMOVED FROM BORE OF "D" FLAP TRACK UPPER ASSEMBLY FOUND BUSHINGS TO MEASURE BEYOND LIMITS OF .6245 - .6255 PER DRAWING 1159WM20107. RT "D" TRACKSDR DXTA2016030706202Flap Track · corrodedRIGHT FLAP TRACK SUPPORT FITTING C, CORROSION FOUND AT FLAP TRACK SUPPORT FITTING BOLT HOLE. AFTER CORROSION WAS REMOVED FROM BORE OF "C" FLAP TRACK UPPER ASSEMBLY FOUND BUSHINGS TO MEASURE BEYOND LIMITS OF .7495 - 07505 PER DRAWING 1159WM20105. RT "C" TRACKSDR DXTA2016030706201Flap Track · corrodedRIGHT FLAP TRACK SUPPORT FITTING B, CORROSION FOUND AT FLAP TRACK SUPPORT FITTING BOLT HOLE. AFTER CORROSION WAS REMOVED FROM BORE OF "B" FLAP TRACK UPPER ASSEMBLY FOUND BUSHINGS TO MEASURE BEYOND LIMITS OF .8760 -.8770 PER DRAWING 1159WM20056. RT "B" TRACK SDR DXTA2016030706200Flap Track · corrodedRIGHT FLAP TRACK SUPPORT FITTING A, CORROSION FOUND AT FLAP TRACK SUPPORT FITTING BOLT HOLE. AFTER CORROSION WAS REMOVED FROM BORE OF "A" FLAP TRACK UPPER ASSEMBLY FOUND BUSHINGS TO MEASURE BEYOND LIMITS OF .6245-.6255 PER DRAWING 1159VVM20054. NEW UPPER FITSDR DXTA2016030706199Flap Track · corrodedLEFT FLAP TRACK SUPPORT FITTING D, CORROSION FOUND AT FLAP TRACK SUPPORT FITTING BOLT HOLE. AFTER CORROSION WAS REMOVED FROM BORE OF "D" FLAP TRACK UPPER ASSEMBLY FOUND BUSHINGS TO MEASURE BEYOND LIMITS OF .6245-.6255 PER DRAWING 1159WM20107. REMOVED LT "D" SDR DXTA2016030706198Flap Track · corrodedLEFT FLAP TRACK SUPPORT FITTING C, CORROSION FOUND AT FLAP TRACK SUPPORT FITTING BOLT HOLE. AFTER CORROSION WAS REMOVED FROM BORE OF "C" FLAP TRACK UPPER ASSEMBLY FOUND BUSHINGS TO MEASURE BEYOND LIMITS OF .7495-.7505 PER DRAWING 1159WM20105. REMOVED LT "C" SDR DXTA2016030706197Flap Track · corrodedLEFT FLAP TRACK SUPPORT FITTING B, CORROSION FOUND AT FLAP TRACK SUPPORT FITTING BOLT HOLE. AFTER CORROSION WAS REMOVED FROM BORE OF "B" FLAP TRACK UPPER ASSEMBLY FOUND BUSHINGS TO MEASURE BEYOND LIMITS OF .8760-.8770 PER DRAWING 1159WM20056. LT FLAP TRACK "BSDR DXTA2016030806196Support Fitting · corrodedLEFT FLAP TRACK SUPPORT FITTING A, CORROSION FOUND AT FLAP TRACK SUPPORT FITTING BOLT HOLE. AFTER CORROSION WAS REMOVED FROM BORE OF A FLAP TRACK UPPER ASSEMBLY FOUND BUSHINGS TO MEASURE BEYOND LIMITS OF .6245-.6255 IAW DWG 1159WM20054. INSTALLED LT A TRACK SDR DXTA2016030706196Support Fitting · corrodedLEFT FLAP TRACK SUPPORT FITTING A, CORROSION FOUND AT FLAP TRACK SUPPORT FITTING BOLT HOLE.SDR DVYA201602250001Trunnion · corrodedCORROSION AT LT AND RT MLG TRUNNION RIB FITTING ATTACH LUGS, FORWARD AND AFT LOCATIONS, DISCOVERED DURING 5000 LANDING INSPECTION. REPAIR ACCOMPLISHED IAW WO CS451500 AND REPAIR DWGS SE45732903 AND SE05732105.SDR UG8A2016030401Attach Fitting · wornTHE LT RUDDER ATTACH POINT NR 3, LOWER BORE ON THE VERTICAL STABILIZER IS WORN BEYOND NOMINAL SIZE. OVERSIZED HOLE OF LT LOWER RUDDER FITTING OF VERTICAL STABILIZER TO FIRST OVERSIZE 0.3125", IAW DWG SE05000102 REV. INITIAL DATED 8 11 2015 WITH FAA APPROVAL SDR UG8A2016021102Hinge Fitting · wornTHE RIGHT ELEVATOR HINGE NR 4 FITTING WAS PREVIOUSLY OVERSIZED WITH A REPAIR BUSHING, THE FITTING ATTACH HOLES BOTH UPPER & LOWER ARE ELONGATED & TAPERED. ENLARGED TWO EACH BORES IN THE RT ELEVATOR NR 4 HINGE FITTING TO SECOND OVERSIZE & ENLARGED UPPER & LOWE
Back to Gulfstream Aerospace G-IV