Gulfstream Aerospace G-IV
Service difficulty reports · 842
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'GIV' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'GIV' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UG8A2016021101Fitting · wornTHE LEFT RUDDER ATTACH POINT NR 3, LOWER BORE ON THE VERTICAL STABILIZER, IS WORN BEYOND NOMINAL SIZE. OVERSIZED HOLE OF LT LOWER RUDDER FITTING ON VERTICAL STABILIZER TO FIRST OVERSIZE .3125" IAW DWG SE05000102 REVISION INITIAL DATED 8 112015 WITH FAA APPROVSDR WWQA20160303001Fire Detector · looseEN-ROUTE, AT APPROX 1 HOUR INTO FLIGHT AT A CRUISE LEVEL OF 430, THE CREW HAD AN INDICATION OF A APU FIRE. THE APU WAS NOT RUNNING. THE CREW FOLLOWED THE AFM CHECKLIST & DISCHARGED THE FIRE BOTTLE & THE INDICATION REMAINED. AT THAT TIME THEY DECLARED AN EMESDR BKEA20160204Actuator · leakingSHORTLY AFTER TOP OF DESCENT, AT FL400, AN AMBER CAS MESSAGE SHOWED, CHECK HYD FLUID QUANTITY. THE CREW NOTED THE LOW LEVEL OF COMBINED SYSTEM HYDRAULIC FLUID. THE LEVEL WAS DEPLETING RATHER RAPIDLY, UNTIL EVENTUALLY INDICATING ZERO AND FOLLOWED BY A RED CAS SDR DXTA2016010706155Valve · faultyDURING LANDING ON MAIN WHEEL TOUCHDOWN ALL BRAKES SEEMED TO APPLY BRAKING ACTION IN AN EVEN MANNER, CAUSING THE NOSE TO SLAM DOWN. THE BRAKES CONTINUED TO APPLY BRAKING ACTION TO A COMPLETE STOP WHILE ON THE RUNWAY. WE USED CAUTION WHEN APPLYING POWER TO CLESDR BKEA201601040001Cabin Pressure · malfunctionedDEPARTED, EN-ROUTE, ON A PART 91 RE-POSITION. LEVELED OFF AT FL410. ABOUT 28 MINUTES INTO THE FLIGHT AND 4 MINUTES AFTER LEVEL FLIGHT, HEARD 3 BONGS COMBINED WITH A CABIN PRESSURE LOW MESSAGE FOLLOWED BY 9.6 DIFFERENTIAL MESSAGE. CONFIRMED THAT WE WERE INSDR DXTA2015121706139Apu · unserviceableDURING POST FLIGHT, ACFT CABIN FILLED WITH ENVIRONMENTAL SYS SMOKE. SWITCHED OFF THE APU AIR & AFTER 15 MINUTES THE SMOKE DISSIPATED.
REMOVED ACCESS PANELS, REMOVED CANNON PLUGS, DISCONNECTED ALL DRAIN LINES. REMOVED BOLTS FOR APU MOUNTING BRACKET AND REMOVSDR DXTA2015121506138Actuator · leakingAMBER CHECK HYD QTY ILLUMINATED. COMBINED QTY INDICATED LOW, FOLLOWED BY RED ARROW THAT DROPPED TO 0 ON QTY SCALE. SIGNIFICANT AMOUNT OF HYD FLUID UNDER THE FUSELAGE ON THE AFT SIDE OF THE ACFT. OPENED AFT BAY BUT NO LEAKS NOTED. AFTER INSPECTING THE TRAILSDR BTVR2015120200002Fitting · corrodedVISUAL INSPECTION OF RT WINGLET MOUNTING HOLES REVEALED CORROSION IN 3 EA OF THE VERTICAL ATTACH BORES FOR THE MOUNTING HARDWARE. CORROSION VERIFIED TO BE OUT OF LIMITS IAW MFG INSTRUCTIONS. WILL REQUIRE OVERSIZING OF BORES WITH APPROVED DATA.SDR BTVR2015120200001Fitting · corrodedVISUAL INSPECTION OF LT WINGLET MOUNTING HOLES REVEALED CORROSION IN 6 EA OF THE VERTICAL ATTACH BORES FOR THE MOUNTING HARDWARE. CORROSION VERIFIED TO BE OUT OF LIMITS IAW MFG INSTRUCTIONS. WILL REQUIRE OVERSIZING OF BORES WITH APPROVED DATA.SDR W6JA20150923006Sump · leakingSHORTLY AFTER DEPARTURE, PAX OBSERVED FUEL LEAKING FROM RT WING. THE LEAK APPEARED TO BE FROM THE RT AILERON & THE OTBD PORTION OF THE WING. EMER WAS DECLARED DUE TO THE FACT THAT THE CREW COULD NOT DETERMINE THE CAUSE OF THE LEAK. CREW LANDED UNEVENTFULLY SDR CA150917007Hinge Fitting · disconnected(CAN) LOWER RUDDER HINGE FOUND DISCONNECTED DURING A LUBRICATION TASK. FWD END OF HINGE WAS NOT ENGAGED IN VERTICAL STABILIZER FITTING WHEN BOLT WAS INSTALLED. HARDWARE WAS FOUND INSTALLED AND SAFE-TIED THROUGH VERTICAL STABILIZER FITTING ONLY.SDR IEYA2015F00000Inverter · failedNR 1 INERTIAL REF UNIT RACK FAN INVERTER SUFFERED A CATASTROPHIC FAILURE DURING GND OPERATION WITH GND POWER APPLIED. THE ENCLOSED UNIT APPEARS TO HAVE EJECTED ITS COVER, INTERNAL PARTS & POTTING, INCLUDING A TOROIDAL TRANSFORMER. THERE ARE SIGNS OF HEAT DAMSDR COZA20150819061Spinner · crackedAN EXTERNAL ENGINE INSPECTION WAS ACCOMPLISHED. CRACKS WERE FOUND EXTENDING OUT FROM EACH OF THE ATTACH HOLES, 3 EA, ON THE LPC ROTATING NOSE CONE FAIRING. THE NOSE CONE FAIRING WAS REPLACED.SDR DXTR2015061901Skin · dentedFOUND DENT ON LOWER SIDE OF RT WING T/E JUST INBD OF THE FLAP. DENT MEASURES APPROXIMATELY 4.0" L X 3.0" W X 0.12 D. REPAIRED IAW ERO-748763 ON W/O 9674415. OK FOR CONTINUED SERVICE.SDR CA150430004Drive Shaft · worn(CAN) LT & RT OTBD FLAP DRIVE SHAFTS ARE CONTACTING WING T/E STRUCTURE DURING FLAP OPERATION. NOTED DURING FLAP OPS CHECKS. FURTHER INSPECTION OF BOTH DRIVE SHAFTS REQUIRED.SDR DBG2015F00000Channel · crackedFLIGHT CREW WERE UNABLE TO CLOSE THE MAIN ENTRANCE DOOR FOLLOWING COMPLETION OF A FLIGHT. MAINTENANCE PERSONNEL INSPECTED AND DISCOVERED A CRACK IN THE MAIN ENTRANCE DOOR ACTUATOR UPPER ATTACHMENT CHANNEL. THE MAIN ENTRANCE DOOR ACTUATOR UPPER ATTACHMENT CHASDR 2015FA0000172Floorboard · damagedCREW REPORTED A PRESSURIZATION EVENT OCCURRED DURING FLIGHT WITH A POSSIBLE OVER PRESSURIZATION INDICATION. THE SAFETY VALVE WAS CHECKED FOR OPERATION AND WAS FOUND INOPERATIVE DUE TO A PLUGGED UP SENSE LINE. THE SENSE LINE WAS FOUND TO HAVE BUGS AND EVIDENCE SDR DXTA2015031605996Unknown · smokeAFTER STARTING APU, BEFORE POWERING ANY AVIONICS, ETC SMOKE COMING FROM COPILOTS SIDE OF THE INSTRUMENT PANEL. PERFORMED A VISUAL INSPECTION FOR SECURITY, FRAYING OF WIRE BUNDLES, ANY SIGNS OF OVERHEATING OR SMOKE DAMAGE IN THE FOLLOWING AREAS: AFT EQUIPMENT SDR DXTA2015030905990Control Panel · failedDURING LEVEL FLIGHT AT 15,000 FEET, EXPERIENCED AUTO THROTTLES DISCONNECT THREE TIMES, AUTOPILOT DISCONNECT ONE TIME. DADC FAIL CAS MESSAGES, EPR 1 ADC FAIL CAS MESSAGE & FIRE DETECTION LT ENGINE LOOP A ALERT. CAS MSGS WOULD CYCLE ON FOR 3 - 5 SECONDS & TOSDR 9PVA2015021600001Actuator · unwanted deployAT ABOUT 1200 FT ON CLIMB OUT, CREW NOTICED AURAL WARNING & THE CAS SHOWED A RED L REV UNLOCKED INDICATION.SDR BKE2014F00000Line · failedSMOKING OUT OF RT ENG. FOUND FAILED AIR CONDITIONING LINE & REFRIGERANT OIL OUT OF COWLING. RETURNED TO SERVICE.SDR WWQA20141203001Unknown · malfunctionedDEPARTED & SELECTED GEAR UP & LT MLG DID NOT RETRACT. LANDED & MX ISSUED A FERRY PERMIT WHERE THE ACFT COULD BE REPAIRED. PUT ACFT ON JACKS INSPECTED THE MLG & FOUND NO DEFECTS. CLEANED & LUBED ALL ACTUATORS & SWITCHES IAW ACFT AMM. PERFORMED SEVERAL GEAR SDR GR4D2014112400002Flap Track · corrodedLEFT D FLAP TRACK UPPER FITTING CORRODED, REPLACED UPPER FITTING WITH A NEW ONE.SDR GR4D201411240003Flap Track · corrodedLT WING C FLAP TRACK UPPER FITTING CORRODED, REPLACED UPPER FITTING WITH NEW ONE.SDR 2014FA0000686Control Box · malfunctionedDURING APPROACH, FLAPS FAILED TO EXTEND BEYOUND 8 DEGREES ON TWO OCCASSIONS. THE ACFT LANDED WITHOUT INCIDENT. TROUBLESHOOTING REVEALED THAT THE DWELL BOX WAS AT FAULT. THE DWELL BOX CHANGE AND THE ACFT WAS RETURNED TO SERVICE.SDR GR4D2014100810002Failsafe · corrodedFAILSAFE FITTING SHOWS EVIDENCE OF CORROSION. R & R FITTING IAW DWG 1159CS20052.SDR GR4D201410080003Failsafe · corrodedFAILSAFE FITTING SHOWS EVIDENCE OF CORROSION. R & R FITTING, PN 1159CSM20022-19 IAW DWG 1159CS20052, REF. WO SC2663.15.16SDR GR4D2014FA0000582Angle · crackedCAP ANGLE, CRACKED AT BS 793. REPAIRED IAW ASC 488, REF SC2663.15.7.SDR 2014FA0000581Shear Web · crackedSHEAR WEB, HAS APPROXIMATELY .7500 INCH CRACK AT BS 733.75, REPAIRED IAW SC2663.15.7.27.SDR BKEA2014090301Control Box · malfunctionedAPPROXIMATELY 1 HOUR AFTER DEPARTURE, THE AMBER ANTI-SKID FAIL MSG CAME ON. AFTER CONSULTING THE CHECKLIST, THE CREW ELECTED TO RETURN TO BASE. IT WAS DETERMINED TO BE AN ANTI-SKID CONTROL BOX ASSEMBLY THAT IS THE LIKELY CAUSE. A REPLACEMENT UNIT HAS BEEN OSDR GR4D201408221408Fitting · corrodedLEFT FLAP TRACK LOWER ATTACH FITTING CORRODED, R & R FITTING.SDR GR4D201408220408Attach Fitting · corrodedRT D TRACK UPPER ATTACH FITTING CORRODED, REPLACED ATTACH FITTING REF W/O SC2617.22.20.SDR GR4D201408220001Flap Track · corrodedLT FLAP TRACK CORRODED, REPLACED FLAP TRACK.SDR DXTA2014072105825Unknown · malfunctionedON LANDING ROLL OUT, APPLIED THE BRAKES AT 70 KTS. NO BRAKING ACTION UNTIL BRAKE PEDALS WERE FULLY DEPRESSED. BRAKES GRABBED & IMMEDIATELY RELEASED. OCCURRED THROUGHOUT THE LANDING ROLLOUT & ON TAXI TO THE RAMP. FELT LIKE THE ANTI-SKID SYS WAS RELEASING SDR DXTA2014020505637Acm · malfunctionedCOCKPIT FILLED WITH SMOKE RAPIDLY 10 MINUTES AFTER APU STARTED UP FOLLOW BY BURNING SMELL. WE SHUT DOWN THE ACFT RIGHT AWAY. ALSO SMOKE IN THE MAIN CABIN. UNABLE TO DETERMINE WHERE THE SMOKE IS COMING FROM. COMPLIED WITH AIR CYCLE MACHINE REPLACEMENT IAW CSDR DXTA2014032105694Brake Sys · malfunctionedAFTER LANDING, BRAKE TEMPERATURES WERE LESS THAN 200 DEGREES. AFTER TURNING OFF RUNWAY & DURING TAXING BRAKES STARTED TO HAVE PRESSURE APPLIED ON THEIR OWN. FEET WERE FLAT ON THE FLOOR, RT BRAKE WAS SHOWING ALMOST 300 PSI LT ALMOST 100 PSI. PUMPED THE BRAKSDR Y3PR201403040001Wedge · corrodedLEFT WHEEL WELL, CORROSION ABOVE REAR BEAM ON BOTTOM SIDE OF T/E BOX AT LBL 63. . REMOVED CORRODED WING WEDGE AND REPLACED WITH NEW WING WEDGE.SDR DXTA2014022405666Oven · defectiveOVEN IS INTERMITTENTLY INOPERATIVE. WHEN IT WORKS & IS USE THERE IS AN ODOR OF BURNING ELECTRONICS OR WIRING. REMOVED OVEN PN 50231L-OVS280, SN 0099 & INSTALLED A REPAIRED OVEN PN 50231L-OVS280, SN 0201, OPERATIONS CHECKED GOOD.SDR DXTA2014031005682Plate · corrodedSEVERAL AREAS OF CORROSION LOCATED ON THE NLG AREA, DISCOVERED DURING SCHEDULED INSPECTION. REMOVE CORROSION FROM LT MLG DOOR STRIKE PLATE AND TREATED STEEL ALLOY IAW SRM 51-13-23 51-21-23.SDR PRIA2014F00072Unknown · unknownAIRCRAFT DEPARTED, ENROUTE, AT 25 MINUTES INTO FLIGHT AND AT FL450 PIC NOTICED A 1500LB FUEL IMBALANCE WITH THE LT SIDE READING LOW. FUEL QUANTITY ON LT SIDE CONTINUED TO DECREASE ON BOTH THE PRIMARY AND STANDBY INDICATIONS. IT WAS AT THIS TIME THE PIC SUSPESDR NOZR20140120001Fitting · defectiveAIRCRAFT DEPARTED IAD AT 1657 UTC FOR A SCHEDULED TRIP TO TEB IN ROUTE THE, CHECK HYD QTY, CAS MESSAGE CAME ON. THROUGH CHECKLIST PROCEDURES, IT WAS DETERMINED THE FLT SYS HYD QTY WAS LOW & DECREASING. CREW FOLLOWED QRH PROCEDURES & DIVERTED TO BWI. IN FLIGHSDR DXTA2014012805629Actuator · failedCOULD NOT GET THE HYDRAULICS TO BRING THE DOOR UP TO CLOSE. CLOSES ABOUT 2/3 OF THE WAY & BINDS. R & R THE MED ACTUATOR IAW CMP 521010, MM 52-14-01 & OPERATIONS CHECKED IAW CMP 521005. OPERATIONS CHECKED GOOD.SDR 2014FA0000026Valve · inoperativeANTI-ROTATION VALVE FAILURE TO RELEASE BRAKE PRESSURE TO PERMIT WHEEL ROTATION DURING EXTENSION AND LANDING WHICH DESTROYED BOTH LT LANDING GEAR TIRES.SDR DXTA2013110705560Apu · odorAIR CONDITIONING SYSTEM PRODUCED A DIRTY SOCK ODOR. REMOVED LEFT AND RIGHT WATER SEPARATOR COALESCER BAG AND INSTALLED NEW. COMPLIED WITH CMP 215005 AIR CONDITIONING SYSTEM OPS TEST WITH NO DEFECTS NOTED. THERE IS STILL AN ODOR PRESENT ONLY WHEN THE APU IS RSDR GR4D20131022001Plate · corrodedRIGHT FLIGHT SPOILER SUPPORT PLATE CORRODED.SDR DXTA2013101165539Brake · stickingRIGHT BRAKE STICKING AND PULLING TO RIGHT.SDR 9PVA2014F00043Bleed Band · debondedGRADUAL DECREASE IN POWER TO RIGHT ENGINE. FOUND BLEED BAND DEBONDED.SDR GR4D2014F00008Fitting · corrodedLEFT FLAP "C" TRACK LOWER ATTACH FITTING CORRODED BEYOND REPAIR, IAW WO 2530.19.11.SDR GR4D2014F00007Fitting · corrodedRIGHT FLAP UPPER "D" TRACK FITTING CORRODED BEYOND REPAIR, IAW WO 2530.19.12.SDR GR4D2014F00006Fitting · corrodedLT "D" FLAP TRACK LOWER FITTING WORN BEYOND REPAIR, SEE WO 2530.19.5.
Back to Gulfstream Aerospace G-IV