Mcdonnell Douglas DC-10-15
Service difficulty reports · 338
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC1015' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC1015' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA98509Latch Solenoid · inoperativeDURING HEAVY CHECK, THE FLIGHT ATTENDANT L-4 OXYGEN BOX WOULD NOT OPEN DURING OXYGEN DROP CHECK. REMOVED AND REPLACED LATCH SOLENOID AT L-4 FLIGHT ATTENDANT STATION OXYGEN BOX PER MM 35-20-00, OPERATIONAL CHECKS GOOD PER MM 35-20-00.SDR SCNA98508Seat Track · corrdedDURING HEAVY CHECK IN THE WASTE TANK COMPARTMENT RIGHT TUNNEL 186 STATION 2007 AT THE FLOOR LEVEL OUTER FLOORBEAM WAS CORRODED ON THE END. MATERIAL VERIFICATION TO BE 7075 T6511, FOR EACH SEAT TRACK AND MATERIAL VERIFIED FOR EACH U CHANNEL SPLICE TO BE 7075 TSDR SCNA98507Spar Cap · crackedDURING HEAVY CHECK, THE RIGHT HAND HORIZONTAL STABILIZER XFS77 XE57 WAS FOUND TO HAVE A 2 INCH CRACK AS VIEWED FROM INTERSPAR BOX ON TOP OF FORWARD SPAR AT JUNCTION OF FUSELAGE SKIN ON FORWARD SPAR. MATERIAL VERIFIED 7075 T6 .125 FOR REPAIR DOUBLER -11 AND 1SDR SCNA98506Stringer · corrodedDURING HEAVY CHECK, FORWARD CARGO SUMP AREA BETWEEN STA 899 AND 919 STR 52 WAS FOUND TO HAVE LEVEL 2 CORROSION. MATERIAL LOSS IS OUT OF LIMITS. MATEIRIAL VERIFIED AS 7075.160. FABBED TWO EACH STRINGERS TWO EACH SPLICE AND TWO EACH FILLERS PER SRM 53-10-00 FSDR SCNA98048Power Supply · inoperativeDURING A LINE CHECK, THE EMERGENCY LIGHT SELF TEST FAILED IN THE AFT SECTION OF THE CABIN. REMOVED AND REPLACED THE BATTERY POWER SUPPLY AND BATTERY PACK, FUNCTIONALLY TESTED GOOD.SDR SCNA98505Rib · crackedDURING HEAVY CHECK, THE RIGHT HAND LEADING EDGE INTERNAL HAS A THREE INCH CRACK ON THE LOWER RIB APPROX AT STATION 491. FABRICATED TWO EACH DOUBLERS 7975 .063 AND 7075 .025 AND FILLER 7075 T6 .040 HEAT TREATED AND PRIMED IAW SRM 51-21-01 AND INSTALLED IAW SRMSDR SCNA98504Bracket · crackedDURING HEAVY CHECK, RIGHT HAND LATERAL CONTROL SPOILER MIXER BRACKET HAS A .25 CRACK NOTED ON AFT SPOILER BRACKET ON AFT SIDE AT TRANSITION RADII BETWEEN THE LEGS AND BODY OF THE BRACKET INBOARD LEG. REPLACED WITH A NEW AND IMPROVED MIXER BRACKET P/N APH7275-SDR SCNA98503Support · crackedDURING HEAVY CHECK, THE REMOVAL OF A FLOOR PANEL TO FACILITATE MAINTENANCE REVEALED A CRACKED FLOOR SUPPORT UNDER THE PATIO FLOOR PANEL. FABRICATION OF ONE DOUBLER, 2024 T3 .040 AND ONE FILLER 2029 T3 .032 PER SRM 53-00-01 AND TREATED PER SRM 51-21-01 AND INSSDR SCNA98502Support · corrodedDURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON THE RIGHT TUNNEL 186 END AT FLOOR SUPPORT BEAM END IN THE WASTE TANK COMPARTMENT, APPROXIMATELY STATION 2007, FLOOR LEVEL. REMOVED CORRODED SECTION AND SPLICED IN A REPAIR IN ACCORDANCE WITH SRM 53-70-00,SDR SCNA98501Angle · corrodedDURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON THE RIGHT TUNNEL LEG IN THE WASTE TANK COMPARTMENT, APPROXIMATELY STATION 2007, FLOOR LEVEL. REMOVED CORRODED SECTION AND SPLICED IN A REPAIR IN ACCORDANCE WITH SRM 53-40-00, FIGURE 16.SDR SCNA98037Support · brokenDURING DESCENT, PRESSURIZATION WOULD NOT START A NORMAL DESCENT IN THE AUTO/SEMI MODES. UPON LANDING FLIGHT ATTENDANT REPORTED LOUD CONTINUOUS HISS COMING FROM THE L4 DOOR. FOUND LOWER TELEFLEX SUPPORT BROKEN. REPLACED SUPPORT AND OPERATIONALLY CHECKED GOODSDR SCNA98031Smoke Detector · malfunctionedTWO PASSENGERS WERE CAUGHT SMOKING IN THE LAVATORIES AND THE SMOKE DETECTORS FAILED TO GO OFF. ALL LAVATORY SMOKE DETECTORS SUBJECTED TO LIVE SMOKE TEST WITH NO FAULT FOUND. SMOKE DETECTORS INSPECTED FOR TAMPERING AND NO DEFECTS NOTED.SDR SCNA98029Fastener · shearedDURING A SCHEDULED MAINTENANCE INSPECTION, THE AFT LOWER RIGHT HAND FASTENER WAS FOUND SHEARED OFF ON THE NUT SIDE FOR THE NUMBER FOUR BANJO FITTING ATTACHMENT. THE AREA WAS REWORKED IN ACCORDANCE WITH SERVICE BULLETIN DC10-55-023 REVISION TWO.SDR SCNA98018N1 Indicator · inoperativeNR 3 ENGINE N1 INDICATOR STUCK AT 78 PERCENT WITH TAKEOFF POWER. ENGINE FAIL LIGHT ILLUMINATED AND TAKEOFF ABORTED. REMOVED AND REPLACED NR 3 N1 INDICATOR, FUNCTIONALLY CHECK GOOD.SDR SCNA98001Encoder · failedDURING OXYGEN DROP FOR A SEAT REMOVAL, OXYGEN PANEL AT 8D DID NOT DEPLOY. REMOVED AND REPLACED UNDERSEAT ENCODER AT SEAT 8D PERFORMED OXYGEN DROP AGAIN, OPS CHECKED GOOD.SDR SCNA97339Power Supply · inoperativeFOUND MID CABIN EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY, LIGHTS TESTED GOOD.SDR SCNA97338Power Supply · inoperativeFOUND FORWARD CABIN EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY, LIGHTS TESTED GOOD.SDR SCNA97306Power Supply · inoperativeTHE MID CABIN LEFT FORWARD EMERGENCY LIGHTS WERE FOUND INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY AND BATTERY PACK, LIGHTS TESTED GOOD IAW DC-10 MM 33-51-01.SDR SCNA97305Smoke Detector · failedTHE SMOKE DETECTOR IN THE LAVATORY NEAR THE R-2 DOOR WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED SMOKE DETECTOR, OPS CHECKED GOOD.SDR SCNA97304Lamp · failedTHE NUMBER 1 SMOKE DETECTOR IN THE CENTER CARGO COMPARTMENT WOULD NOT TEST. REMOVED AND REPLACED SMOKE DETECTOR LAMP, OPS CHECKED GOOD.SDR SCNA97296Power Supply · inoperativeTHE OVERWING EMERGENCY LIGHT POWER SUPPLY DOES NOT PASS THE EMERGENCY LIGHT TEST. REMOVED AND REPLACED THE POWER SUPPLY AND BATTERY PACK, SYSTEM TESTED GOOD.SDR SCNA97295Pneumatic Valve · lack of lubeWHILE CONDUCTING A TEST SLIDE/RAFT DEPLOYMENT AT THE L-3 DOOR, THE DOOR WOULD NOT OPEN PNEUMATICALLY. DOOR WAS OPERATED MANUALLY AND THE SLIDE/RAFT DEPLOYED NORMALLY. LUBRICATED OVERIDE HANDLE AND PNEUMATIC VALVE FOR THE L-3 DOOR, DOOR OPS CHECKED NORMAL.SDR SCNA97294Smoke Detector · failedTHE NUMBER 4 SMOKE DETECTOR IN THE AFT CARGO COMPARTMENT WOULD NOT TEST. REMOVED AND REPLACED NUMBER 4 SMOKE DETECTOR, NEW DETECTOR TESTED GOOD PER DC-10 MAINTENANCE MANUAL 26-10-00.SDR SCNA97289Batteries · dischargedTHE R-3 EMERGENCY SLIDE WOULD NOT TEST. REMOVED AND REPLACED TEST BATTERIES, SLIDE TESTED GOOD.SDR SCNA97286Smoke Detector · failedTHE NUMBER 3 AFT CARGO SMOKE DETECTOR WOULD NOT TEST IN FLIGHT. RELAMPED NUMBER 3 AFT CARGO SMOKE DETECTOR, DETECTOR TESTED GOOD.SDR SCNA97279Smoke Detector · failedTHE FORWARD CARGO PIT NUMBER 2 SMOKE DETECTOR DOES NOT TEST. REMOVED AND REPLACED SMOKE DETECTOR, SYSTEM TESTED GOOD.SDR SCNA97276Battery Pack · dischargedTHE EMERGENCY PATH LIGHTING IN THE FORWARD CABIN WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED THE FORWARD CABIN BATTERY PACK, PATH LIGHTING TESTED GOOD.SDR SCNA97136Batteries · dischargedTHE L-3 DOOR SLIDE PRESS TO TEST LIGHT WAS FOUND TO BE DIM. REMOVED AND REPLACED TEST LIGHT BATTERIES. SLIDE TESTED GOOD.SDR SCNA97087Speed Sensor · failedN1 INDICATOR FAILED AND ENGINE FAIL LIGHT ILLUMINATED WHILE ADDING TAKEOFF POWER. REMOVED AND REPLACED NUMBER 1 ENGINE FAN SPEED SENSOR AND TESTED IN ACCORDANCE WITH MM 77-11-01. NO FURTHER DISCREPANCIES NOTED.SDR SCNA97086Light · inoperativeR1 DOOR FORWARD EMERGENCY EXIT LIGHT WAS FOUND INOP. RELAMPED EMERGENCY LIGHT AND FUNCTIONALLY TESTED IN ACCORDANCE WITH MM 33-00. NO DISCREPANCIES NOTED.SDR SCNA97084Smoke Det Lamp · failedPOSITION 2 CARGO SMOKE DETECTOR DID NOT TEST. RELAMPED SMOKE DETECTOR AND FUNCTIONALLY TESTED WITH NO DISCREPANCIES NOTED.SDR SCNA97080Smoke Detector · actuatedSMELLED THE ODOR OF CIGARETTES IN THE VACINITY OF THE LEFT FORWARD LAV. OBSERVED SMOKE AND SMELL WHEN PASSENGER EXITED THE LAV. SMOKE DETECTOR DID NOT ACTIVATE WHEN THE EVENT OCCURRED. FUNCTIONALLY CHECKED THE FORWARD LAV SMOKE DETECTOR IN ACCORDANCE WITHSDR SCNA97072Anti-Skid · failedAFTER LANDING, THE NUMBER 8 TIRE BLEW, CAUSING DAMAGE TO THE RIGHT MAIN LANDING GEAR FLYING DOOR, NUMBER 3 ENGINE THRUST REVERSER BEAVER TAIL, AND THE OUTBOARD CLOSURE RIB OF THE RIGHT INBOARD FLAP. INVESTIGATION REVEALED A DAMAGED TRANSDUCER AT THE NUMBER 8 SDR SCNA97064Battery Pack · dischargedL-3 SLIDE PRESS TO TEST LIGHT DIM. REPLACED BATTERY PACK AND OPS CHECKED GOOD.SDR SCNA97061Coffeemaker · dirtyDURING FLIGHT, THERE WAS AN ELECTRICAL SMOKE SMELL IN THE AFT GALLEY. TURNED GALLEY POWER OFF AND SMELL WENT AWAY. FOUND NUMBER 7 COFFEE MAKER BASE DIRTY, CLEANED BASE AND OPS CHECKED GOOD.SDR SCNA97058Battery · dischargedEXIT LIGHTS AT FORWARD GALLEY L2 AND R2 DOORS DO NOT ILLUMINATE IN TEST POSITION. REMOVED AND REPLACED BATTERY SUPPLY IN ACCORDANCE WITH 33-50-00. OPS TESTED GOOD.SDR SCNA97054Gear Pins · not removedLANDING GEAR WOULD NOT RETRACT ON CLIMB-OUT. RETURNED TO MSP, FOUND GEAR PINS INSTALLED. REMOVED GEAR PINS.SDR SCNA97053Power Supply · inoperativeFORWARD OVERHEAD EMERGENCY LIGHT POWER SUPPLY FAILED SELF TEST. REMOVED AND REPLACED POWER SUPPLY IN ACCORDANCE WITH 33-51-01 AND OPS CHECKED GOOD.SDR SCNA97025Battery Pack · dischargedOVERWING OVERHEAD EMERGENCY LIGHTS FAIL SELF TEST. REMOVED AND REPLACED POWER SUPPLY BATTERY PACK IN ACCORDANCE WITH MM 33-51-01 AND SYSTEM TESTS NORMAL.SDR SCNA97023Spar Cap · crackedFOUND CRACK IN LEFT WING REAR SPAR LOWER CAP AT APPROXIMATE STATION XORS410. INSTALLED TEMPORARY REPAIR WITH PERMANENT REPAIR SCHEDULED WITHIN 5,000 CYCLES.SDR SCNA97020Circut Breaker · failedEMERGENCY LIGHTS WILL NOT TEST IN THE COCKPIT. FOUND BAD BREAKER B1-381. REMOVED AND REPLACED BREAKER AND OPS CHECKED GOOD.SDR SCNA97019Battery Pack · dischargedFORWARD CABIN EMERGENCY LIGHT REMAINED ON WITH TEST SWITCH IN OFF POSITION. FOUND EMERGENCY LIGHT BATTERY PACK TO BE DEFECTIVE AND FOUND CHAFED WIRE L2750AS20 AT DOOR EXIT SIGN. REMOVED AND REPLACED BATTERY PACK AND REPAIRED WIRE IN ACCORDANCE WITH APPROVED SDR SCNA97018Battery Pack · dischargedFOUND FORWARD CABIN EMERGENCY LIGHT INOP DURING LINE CHECK. REMOVED AND REPLACED EMERGENCY BATTERY POWER SUPPLY IN ACCORDANCE WITH DC-10-15, TAFI AND OPS CHECKED GOOD IN ACCORDANCE WITH MM 33-50-00.SDR SCNA97013Battery Pack · dischargedFOUND FORWARD CABIN OVERHEAD EMERGENCY LIGHTS INOP. REMOVED AND REPLACED FORWARD BATTERY POWER SUPPLY IN ACCORDANCE WITH 33-51-01 AND OPS CHECKED GOOD.SDR 97ZZZX524Skin · dentedTEMPORARY REPAIR INSTALLED ON LT HORIZ STAB UPPER SIDE STA XE 103 YA189. REMOVED REPAIR FOUND DENTS. OUT OF LIMITS. CUT OUT DENTED AREAS IAW DOUGLAS DWG 312891/96-10-16-18. FABRICATED DOUBLERS PER SAME DWG. ALODINED AND PRIMED IAW DC 10 SRM 51-21-01. INSSDR SCNA97008Light · inoperativeFORWARD CABIN EMERGENCY TRACK LIGHTING WAS FOUND INOP IN AFT HALF OF FORWARD CABIN. REPAIRED SHORTED SUPPLY WIRING AT SEAT 8HJK, OPS CHECKED GOOD.SDR SCNA97005Switch Assy · inoperativeL1 DOOR EMERGENCY SLIDE PUSH TO TEST BUTTON WAS INOP. REMOVED AND REPLACED COMPLETE BATTERY, PLUG AND SWITCH ASSEMBLY, OPS CHECKED GOOD.SDR SCNA96447Battery · dischargedFOUND L2 DOOR ESCAPE SLIDE PRESS TO TEST LIGHT INOP. RELAMPED AND REPLACED BATTERIES AND OPS CHECKED GOOD IN ACCORDANCE WITH MM 25-61-01.SDR SCNA96445Support · corrodedDURING HEAVY MAINTENANCE, FOUND MID GALLEY FLOOR SUPPORT CORRODED AT FS 879 RBL 36. REMOVED AND REPLACED FLOOR SUPPORT IN ACCORDANCE WITH SRM 53-60-01 AND SRM 51-30-00.SDR SCNA96444Support · corrodedDURING HEAVY MAINTENANCE, FOUND CORROSION ON FLOOR SUPPORT AT FS 824, RBL 36 UNDER MID GALLEY. REMOVED FLOOR SUPPORT, FABRICATED AND INSTALLED A NEW FLOOR SUPPORT IN ACCORDANCE WITH SRM 51-21-01 AND 51-33-01.
Back to Mcdonnell Douglas DC-10-15