Mcdonnell Douglas DC-8-71
Service difficulty reports · 341
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC871' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC871' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA002988Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SKIN AT MARKER BEACON AT STA 680 - 660 AND L36L TO L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA002914Support · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE BULKHEAD MIDDLE RT SUPPORT (HORIZONTAL) AT STA 70, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-4.SDR RRXA002917Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE R/H LWR. ACCESS PANEL 547, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0 AND EO 00-196.SDR RRXA002916Panel · delaminatedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND FASTENERS PULLING THROUGH THE CENTER PANEL BETWEEN MAIN GEAR DOOR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-SDR RRXA002915Web · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO BOTH SIDES ON THE L/H FLOOR BEAM PRESS WEB AT STA 857 AND LONGERON 0 TO =60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-SDR RRXA002880Trunnion · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE TOP LT. SIDE OF NLG TRUNNION FITTING. ------------------------CX----------------------------SDR RRXA002879Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED LOCK HOLES TO THE F/E LT. SEAT TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-3-0.SDR RRXA002878Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SUB-FLOOR ANGLE AT STA -99 FO'S SIDE RBL 48" 12" BELOW AND RT. OF FO'S RUDDER PEDELS, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1SDR RRXA002877Seat Track · wornDURING A MAINTENANCE VISIT FOUND DEEP WEAR AREAS TO THE CAPT. FWD RT. SEAT TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0.SDR RRXA002876Web · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON SUB-FLOOR WEB BELOW RELAY CONTROL PANEL AT STA 8 0 TO -12 FROM CL TO RBL 68", DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. ---------------------CX----------------------SDR RRXA002875Skin · dentedDURING A MAINTENANCE VISIT FOUND A DENT TO THE EXTERIOR SKIN AT STA 1586 BETWEEN L21R-L22R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1SDR RRXA002874Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SKIN AT STA 1296 AND L21R-L20R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. --------------------CX--------------------SDR RRXA002873Frame · crackedDURING A MAINTENANCE VISIT FOUND A CRACK AND SHEARED FASTENERS TO THE EXTERIOR FRAME/WEB AT STA 816 AND XCW 69, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLSDR RRXA002872Skin · dentedDURING A MAINTENANCE VISIT FOUND A DENT TO THE EXTERIOR SKIN AT STA 120 AND L34R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-1, 53-2-0.SDR RRXA002871Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE EXTERIOR SKIN BETWEEN STA 742-781 AND L35L-L35R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA002883Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A 1 1/4 INCH CRACK TO THE TOP FLOORBEAM AT STA -10 IN COCKPIT AND LBL -10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-0.SDR RRXA002882Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGAGED LOCK HOLES AND SCALOPED WEAR AREAS ON THE 2ND OBS SEAT TRACK (RIGHT), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-3-0.SDR RRXA002881Intercostal · crackedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND A CRACK TO THE RIVETS ON INTERCOSTAL AT STA 5 AND L29R. ----------------------------CX-----------------------------SDR RRXA002912Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMGE AND BROKEN OFF SCREWS IN TRACK FLANGE ON SEAT TRACK AT STA Y=1360-1580 AND X-60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATESDR RRXA002911Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND BROKEN OFF SCREWS IN TRACK FLANGE TO SEAT TRACK AT STA Y=1360-1580 AND X-46, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATSDR RRXA002910Seat Track · brokenDURING A MAINTENANCE VISIT FOUND A LUG BROKEN OUT ON THE SEAT TRACK AT STA 1483 AND X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-3-0 AND STC SA180250 ASDR RRXA002909Seat Track · brokenDURING A MAINTENANCE VISIT FOUND A BREAK TO THE SEAT TRACK ON FWD. END. AT STA 1580-1600 AND X-46, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SSDR RRXA002908Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMGE TO THE SEAT TRACK AT STA 70-260 AND X-52, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW TMS 60-6549 FRSDR RRXA002907Seat Track · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE SEAT TRACK AT STA Y=380-440 AND X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW TMS 60-6549 FROM STC SDR RRXA002906Hinge · gougedDURING A MAINTENANCE VISIT FOUND A DEEP GOUGE AT EYEBOLT ATTACK I/B #1 R/H ELEV. HINGE SUPPORT FITTING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW SDR RRXA002905Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND BROKEN OFF SCREWS IN TRACK FLANGE ON SEAT TRACK AT STA Y=1160-1380 AND X=+60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICASDR RRXA002904Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND BROKEN OFF SCREWS IN TRACK FLANGE ON SEAT TRACK AT STA Y=940-1160 AND X=+60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATSDR RRXA002903Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND BROKEN OFF SCREWS IN TRACK FLANGE ON SEAT TRACK AT STA Y=1060-1300 AND X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATESDR RRXA002902Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND BROKEN OFF SCREWS IN TRACK FLANGE ON SEAT TRACK AT STA Y=1140-1460 AND X=-60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICASDR RRXA002901Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND BROKEN OFF SCREWS IN TRACK FLANGE TO SEAT TRACK AT STA Y=480-700 AND X=-60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATESDR RRXA002900Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND BROKEN OFF SCREWS IN TRACK FLANGE AT SEAT TRACK AT STA Y=70-380 AND X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PSDR RRXA002899Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMGE AND BROKEN OFF SCREWS IN TRACK FLANGE TO THE SEAT TRACK AT STA Y=70-240 AND X=+46, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICASDR RRXA002898Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND BROKEN OFF SCREWS IN TRACK FLANGE TO THE SEAT TRACK AT STA Y=380-600 AND X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICASDR RRXA002897Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND BROKEN OFF SCREWS IN TRACK FLANGE ON SEAT TRACK AT STA 380-620 AND X+25, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PSDR RRXA002896Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND BROKEN OFF SCREWS IN TRACK FLANGE TO THE SEAT TRACK AT STA Y=70-380 AND X+25, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICASDR RRXA002895Seat Track · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED LOCK HOLES TO THE FE'S RT. SEAT TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-20D.SDR RRXA002894Seat Track · wornDURING A MAINTENANCE VISIT FOUND ELONGATED LOCK HOLES AND SCALLOPED WEAR AREA TO THE 2ND OBSERVERS SEAT TRACK (LT), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-3-0.SDR RRXA002893Seat Track · wornDURING A MAINTENANCE VISIT FOUND DEEP WEAR AREAS TO THE FO'S FWD. RT SEAT TRACK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-3-0.SDR RRXA002884Skin · misrepairedDURING A MAINTENANCE VISIT FOUND AN IMPROPER REPAIR AT INTERNAL SKIN DOUBLER AT STA 1380 TO 1400 AND L27R TO L26R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21 SDR RRXA003819Skin · puncturedDURING A MAINTENANCE VISIT FOUND PUNCTURE DAMAGE TO O/B END OF #2 GROUND SPOILER ON L/H WING AT STA. XRS162.263, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTASDR RRXA003811Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO ENGINE INLET COWL AT 5:30 POSITION, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW EO#00-196 WITH APPROVSDR RRXA002892Fitting · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE "C" PIT DOOR WELL STOP FITTING AT STA 1180 AND L27L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SSDR RRXA002891Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND SCREWS BROKEN OFF IN TRACK FLANGE AT STA Y=1140-1460 AND X=-46, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PARTAND INSDR RRXA002890Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND SCREWS BROKEN OFF IN TRACK FLANGE AT STA Y=620-717 AND X=+25, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSSDR RRXA002889Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMGE AND SCREWS BROKEN OFF IN TRACK FLANGE AT STA Y=160-240 AND X=-25, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTSDR RRXA002888Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND SCREWS BROKEN OFF IN TRACK FLANGE AT STA Y=70-140 AND X=-25, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTSDR RRXA002887Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND SCREWS BROKEN OFF IN TRACK FLANGE AT STA Y=70-240 AND X=-46, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTSDR RRXA002886Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE SEAT TRACK AT STA 1220-1340 AND RBL 25", DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRSDR RRXA002885Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON THE VERTICAL ANGLE AT STA -67 AND LBL 58" 10" BELOW LEVEL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLSDR RRXA002865Clip · crackedDURING A MAINTENANCE VISIT FOUND CRACKED CAN'T LWR. CLIPS FOR STRINGERS 60-64 AT TOP OF RT WING ACCESS HOLE 505A AT STA XW 508, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-
Back to Mcdonnell Douglas DC-8-71