Mcdonnell Douglas MD 83
Service difficulty reports · 3,415
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD83' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'MD83' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YYFA20140105001A/C Pack · shutdownLEFT PACK SHUT DOWN AT 4000, UNABLE TO CONTROL PRESS AT FL240 USING RT PACK.SDR WX0A071812Battery · dischargedEMERGENCY LIGHTS AT ROW 37 & ABOVE AFT FLIGHT ATTENDANT`S STATION INOPERATIVE. R & R BATTERIES IN BATTERY PACK B5-27 IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.SDR WX0A071811Battery · dischargedEMERGENCY LIGHTS AT ROWS 27 & 31 INOPERATIVE. R & R BATTERIES IN BATTERY PACK B5-106 IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.SDR WX0A071809Battery · dischargedAFT FLIGHT ATTENDANT`S FLASHLIGHT INOPERATIVE. R & R AFT FLIGHT ATTENDANT`S FLASHLIGHT BATTERY IAW AMM 25-60-00, OPERATIONS CHECKED GOOD.SDR WX0A071814Battery · dischargedROW 24 & 25 OVERHEAD EMERGENCY LIGHT INOPERATIVE. R & R BATTERIES AT ROW 24 & 25. OPERATIONS CHECKED NORMAL IAW AMM 33-50-00.SDR WX0A071813Battery · dischargedEMERGENCY LIGHT OUT IN TAIL COMPARTMENT. R & R EMERGENCY BATTERY POWER SUPPLY IAW AMM 33-53-01. OPERATIONS CHECKED GOOD.SDR WX0A071808Beam · corrodedAFT CARGO DOOR CUTOUT LOWER JAMB BEAM CORRODED. REMOVED CORROSION & CUTOUT SMALL SECTION AT AFT DOOR STOP ON BEAM. FABRICATED REPAIR DOUBLER & REPAIR PARTS, LOCATED, DRILLED & INSTALLED PERMANENT REPAIR IAW MD80 SRM 53-05 FIGURE 123A OPTION 2SDR WX0A071807Power Supply · inoperativeEMERGENCY OVERWING LIGHTS INOPERATIVE. R & R OVERWING POWER SUPPLY & OPERATIONS CHECKED GOOD IAW AMM 33-53-00.SDR YYFA20131231002Tire · blownLEFT NUMBER TWO TIRE BLOWN.SDR YYFA20131231001Warning System · activatedAFTER LANDING LOOP A FAULT LIGHT FWD BIN SMOKE DETECTOR.SDR WX0A071806Power Supply · inoperativeOVERWING EMERGENCY LIGHTS INOPERATIVE, LT & RT SIDES. REMOVED POWER SUPPLY CONTROLLER FOR EXTERNAL EMERGENCY LIGHTS. REPLACED POWER SUPPLY FOR EXTERIOR LIGHTS IAW MM 33-53-00. REMOVED RELAY FOR EXTERIOR EMERGENCY LIGHTS IAW MM 33-53-00. R & R OVERWING POWESDR WX0A071803Cover · looseL2 DOOR SLIDE PACK COVER LOOSE & INTERFERES WITH OPENING & CLOSING. SECURED L2 DOOR SLIDE COVER IAW AMM 25-62-00. ACFT OK FOR CONTINUED SERVICE.SDR WX0A071802Lanyard · brokenRIGHT R1 DOOR EVAC SLIDE LANYARD BROKEN. REPLACED R1 DOOR EVAC SLIDE LANYARD IAW AMM 25-62-00.SDR WX0A071801Fitting · brokenR1 DOOR EVAC SLIDE INTERLOCKING CLIP BROKEN. REPLACED R1 DOOR EVAC SLIDE BRACKET IAW SRM 53-30-01 & IPC 25-60-00-42D.SDR WX0A20131231001Slide · unsecureL1 DOOR SLIDE FELL OUT OF COMPARTMENT. INSTALLED L1 DOOR EVAC SLIDE IAW 25-62-00, NO DEFECTS NOTED.SDR YYFA20131229001Engine · power lossLEFT ENGINE FAILED TO ACCELERATE.SDR WX0A071805Skin · crackedL1 DOOR SKIN CRACKED AT HOLD OPEN CUTOUT. FABRICATED REPAIR DOUBLER & INSTALLED REPAIR DOUBLER IAW MD-80 SRM 52-05 FIG 20A.SDR WX0A071804Lock · dirtyL1 GIRT BAR DIFFICULT TO ARM & DISARM. CLEANED GIRT BAR LOCKS, ARM & DISARM GIRT BAR, OPERATIONS CHECKED GOOD IAW MM 25-62-00.SDR WX0A071800Latch · dirtyFLIGHT ATTENDANT`S REPORT L2 DOOR GIRT BAR IS DIFFICULT TO ENGAGE & DISENGAGE. CLEANED DEBRIS OUT OF GIRT BAR LATCH IAW AMM 25-62-01, OPERATIONS CHECKED GOOD.SDR YYFA20131226001Warning Light · activatedTHRUST REVERSER UNLOCK LIGHT CAME ON & STAYS ON WHEN TAKEOFF POWER IS APPLIED.SDR WX0A2013122371797Coalescer Bag · contaminatedFLIGHT ATTENDANT’S SITTING IN AFT CABIN JUMP SEATS REPORT STRONG CHEMICAL EXHAUST FUMES. INSPECTED RT & LT ENGINE INLETS NO OIL LEAKS NOTED AT THIS TIME. OIL RESIDUE ON RT PACK ACM, RAN LT PACK & NO ODOR NOTED AT THIS TIME. REMOVED AND REPLACED LT & RT A/C SDR WX0A071796Light · inoperativeESCAPE PATH LIGHTING IS NO LONGER ILLUMINATED UPON TAKEOFF. AFTER DIMING THE CABIN LIGHTS WE NOTICED THAT THE ESCAPE LIGHTING WAS NOT ILLUMINATED. TURNED ON ALL CABIN LIGHTING & OPENED WINDOW SHADES & ALLOWED PHOTO ILLUMINATION FLOOR ESCAPE PATH LIGHT STRIPSDR YYFA20131221001Fire Warning · activatedAFT CARGO FIRE LOOP B LIGHT ILLUMINATED INFLIGHT & WOULD NOT GO OUT AFTER QRH PROCEDURES.SDR WX0A071831Seat Track · corrodedSEAT TRACK AT LBL 54 & FS 237 CORRODED. R & R SECTION OF SEAT TRACK AT LBL 54, FS 200 TO FS 237 IAW SRM 53-05 PARA 4.SDR WX0A071793Fairing · corrodedRIGHT FUSELAGE AT WING BODY FAIRINGS HAS NUMEROUS SPOTS OF CORROSION AT ATTACHMENT POINTS. FABRICATED DOUBLER, LOCATED, DRILLED PARTS & INSTALLED PERMANENT REPAIR IAW MD80 SRM 51-30-5 & 53-04, PAR 7, FIG 57.SDR WX0A071795Battery · dischargedR1 DOOR EMERGENCY LIGHT INOPERATIVE. R & R ONE EACH BATTERY IN R1 DOOR EMERGENCY LIGHT IAW AMM 33-53-00, CHECKED GOOD.SDR WX0A2013122071794Acm · odorBOTH APU`S RUNNING A/C PACKS, EXHAUST ODOR IN CABIN. REMOVED AND REPLACED LEFT AIR CYCLE MACHINE. OPS AND LEAK CHECKED OK IAW AMM 21-51-01.SDR WX0A071791Battery · dischargedVENTRAL STAIRS OVERHEAD EMERGENCY LIGHTS INOPERATIVE & WILL NOT TEST. R & R BATTERIES IN BATTERY PACKS B5-27 & B5-28. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.SDR YYFA2013201317002Connector · dirtyMID CARGO FIRE DETECTION LOOP A COMES ON IN FLIGHT & STAYS ON AFTER QRH PROCEDURE. CLEANED CONNECTOR ON MID CARGO COMPARTMENT LOOP A DETECTOR, OPERATIONS CHECKED GOOD. AMM BITE TEST OPERATIONS CHECKED GOOD AMM 26-16-00.SDR YYFA2013201317001Warning System · false activationON TAKEOFF FROM KMIA THE TAKEOFF WAS ABORTED FOR A RT REVERSER UNLOCK LIGHT. VISUALLY CHECKED RT REVERSER NO DISCREPANCIES NOTED. CYCLED RT REVERSER, PASSED FUNCTIONAL & INDICATION TEST. COULD NOT DUPLICATE SQUAWK MD80 AMM 78-30-00.SDR WX0A07177Battery · dischargedCOCKPIT OVERHEAD LIGHTS DO NOT COME ON WITH EMERGENCY LIGHT TEST. R & R BATTERIES FOR EMERGENCY LIGHTS IN FWD SECTION IAW AMM 33-50-00, OPERATIONS TESTED GOOD.SDR WX0A071778Battery · dischargedMID CABIN OVERWING EXIT DOOR AFT EMERGENCY LIGHT LOWER INOPERATIVE, BATTERIES ARE OUT OF DATE. R & R BATTERY IAW AMM 33-53-00, OPERATIONS CHECKED GOOD.SDR WX0A071776Battery · dischargedFORWARD OVERWING EMERGENCY LIGHTS OUT. R & R EMERGENCY LIGHTS BATTERIES IAW MM33-53-00, OPERATIONS CHECKED GOOD.SDR YYFA20131213001Pa System · noisyL2 PA ATT ALERT SQUEALS WHEN PRESSED.SDR WX0A071779Battery · dischargedBOTH LT & RT OVERWING EXIT IDENTIFIER LIGHTS WON’T SHUT OFF. R & R BATTERY POWER SUPPLY IAW MD80 AMM 33-53-00 & WDM 33-51-14, BATTERY SUPPLY B5-207, OPERATIONS CHECKED GOOD.SDR WX0A071775Battery · dischargedMID CABIN EMERGENCY LIGHTS INOPERATIVE. R & R BATTERIES IN BATTERY PACK B5-103 IAW MD80 AMM 33-53-00, OPERATIONS CHECKED NORMAL.SDR YYFA20131211001Handset · inoperativeAFT ATTENDANT HANDSET IS INOPERATIVE. R & R AFT FLIGHT ATTENDANT HANDSET, OPERATIONS CHECKED GOOD.SDR WX0A071772Fcu · leakingBURNING SMELL FROM VENTS WHEN APU AIR SELECTED ON, APU FCU LEAKING FUEL. R & R APU FCU IAW MM 49-30-01, OPERATIONS LEAK CHECKED GOOD.SDR YYFA20131208001Engine · power lossDURING TAKEOFF WITH ENG ANTI-ICE ON & WHEN AUTO THROTTLES ENGAGED, LT ENG SPOOLED SLOW & DID NOT MAKE EPR WHICH FIRED THE ART MANUALLY ADVANCED THROTTLE TO MAKE TAKEOFF EPR.SDR WX0A071770Fan · malfunctionedFLIGHT ATTENDANT CALLED UP COMPLAINING OF BURNING SMELL BETWEEN ROWS 18 - 21. AFTER 7 MINUTES SMELL WENT AWAY. COMPLIED WITH TASK CARD F0592102 CABIN ODOR, SMOKE & TROUBLE SHOT. LOUD GRINDING NOISE COMING FROM CABIN FLOOR AT ROWS 15 - 18 LT SIDE. PULLED CSDR 2013FA0000715Housing · crackedTHRUST REVERSER CONTROL VALVE HAS A PIN HOLE ON SIDE OF PRESSURE PORT.SDR YYFA20131205001Button · missingREAR CABIN ATTENDANT HANDSET, PRESS TO TALK, BUTTON MISSING.SDR WX0A071767Seat Track · corrodedSEAT TRACK AT LBL 44 FS 200 TO FS 218 CORRODED. R & R SEAT TRACK AT LBL 44 FS 200 TO FS 218 IAW MD-80 SRM 53-05 FIG 4H.SDR WX0A2013120400769Control Valve · burnedAPU SUSPECTED OF CAUSING CABIN ODOR. R & R APU LOAD CONTROL VALVE IAW AMM 49-50-01 PARA 2 A & B. BURNED OIL DISCOLORATION AT 7 O`CLOCK ON PREVIOUSLY INSTALLED VALVE.SDR YYFA20131204001Interphone · malfunctionedFORWARD PA INTERPHONE NOT WORKING PROPERLY, VOICE SOUNDS VERY LOW OR DOES NOT SOUND AT ALL DINGS. CALL BUTTON TO FLIGHT DECK SOMETIMES DOES NOT SOUND AT ALL.SDR YYFA20131203001Microphone · faultyPASSENGER ADDRESS SYS FROM COCKPIT ON HANDSET OR AUDIO PANEL, CAPTAIN & FLIGHT OFFICER, INOPERATIVE. R & R PA MIC PREAMP ASSEMBLY SYS, OPERATIONS CHECKED GOOD.SDR YYFA20131202001Handset · disconnectedFLIGHT ATTENDANT AFT HANDSET INOPERATIVE. FOUND UNPLUGGED HANDSET AFT ATTENDANT, PLUGGED IN HANDSET, OPERATIONS CHECKED.SDR WX0A071766Battery Pack · dischargedIN ACCORDANCE WITH MEL 25-09 SIT 1 DMI 5542, AFT CABIN FLASHLIGHT NOT BLINKING. R & R AFT CABIN FLASHLIGHT BATTERY PACK IAW AMM 25-60-00, OPERATIONS CHECKED GOOD. THIS CLEARS MEL 25-09 SIT 1, DMI 5542, INOPERATIVE PLACARD REMOVED.SDR WX0A071765Compressor · stalledON TAXI OUT WE RECEIVED 5 COMPRESSOR STALLS. UNABLE TO DETERMINE WHICH ENG. CHECKED RIG & TRIM OF LT ENG IAW MD80-MM-71-00-00 CONFIG 1. DRAINED MOISTURE TRAP, CHECKED PRESSURIZATION & DUMP VLV IAW MD80-73-20-00, ACCOMPLISHED M739, OPERATIONS CHECKED NORMAL,SDR YYFA20131201003Unknown · malfunctionedAFTER DEPARTING KLCK WITH NORMAL PROCEDURES, WE NOTICED THE FLOW LIGHT ILLUMINATED. STOP CLIMB AT 230 & RAN QRH, UNABLE TO MAINTAIN CABIN PRESS & RETURNED TO KLCK.
Back to Mcdonnell Douglas MD 83