Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '340B' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '340B' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MALA060266Battery Pack · no testFAILED CAP CHECK PER DIEHL CMM WO 408128. REPLACED BATTERY PACK P/N 3301-51, S/N 1404.SDR MALA060258Frame · corrodedDURING 2 YEAR CHECK IN BNA, FOUND FRAME AT FS 258, FROM RBL 9.0 TO LBL 9.0 IS CORRODED AND HAS BEEN REPAIRED IAW MESABA EO NR S53108. REF: EAMS WORK ORDER 213743 TASK 2522.SDR 05032006ABellcrank · unknownAILERONS FEEL STIFF. R&R LT AILERON BELLCRANK ASSY. O/B IAW 27-11-40-4 OPS CHECK GOOD.SDR MALA060261Web · crackedDURING 2 YEAR CHECK IN BNA, FOUND VERTICAL WEB OF FRAME AT FS 294 AND RBL 18, JUST BELOW FLOOR LEVEL IS CRACKED AND HAS BEEN REPAIRED IAW MESABA EO S53102. REF: EAMS WORK ORDER 213743, TASK 1503.SDR 04202006AConnector · dirtyAUTOCOARSEN HIGH LIGHT DID NOT ILLUMINATE. CLEANED CONNECTORS TO AUTOCOARSEN COMPUTER AND SWITCHER, PERFORMED AUTOCOARSEN OPS TEST IAW 61-22-00, OPS TEST GOOD.SDR 04202006BControl Unit · malfunctionedNR 1 TORQUE GAUGE READS ZERO. REMOVED AND REPLACED NR 1 ENGINE DEC PN ON/OFF 6071T20P16, SN ON ECDT1503, SN OFF ECDT1921 IAW 74-00-00. OPS CHECK GOOD.SDR MALA060263Seat Track · corrodedDURING 2 YEAR CHECK IN BNA, FOUND SEAT TRACK AT BLO BETWEEN FS 294 AND 319 IS CORRODED. THE OUT OF LIMITS AREA HAS BEEN REPAIRED IAW MESABA EO#S53342. REF: EAMS WORK ORDER 213743 TASK 2517.SDR MALA060262Seat Track · corrodedDURING 2 YEAR CHECK IN BNA, FOUND SEAT TRACK AT LBL 18.3, BETWEEN FS 294 AND 319 IS CORRODED. THE "OUT OF LIMITS" AREA HAS BEEN REPAIRED IAW MESABA EO#S53342. REF: EAMS WORK ORDER 213743 TASK 2516.SDR MALA060260Panel · corrodedDURING 2 YEAR CHECK IN BNA, FOUND LOWER END OF COCKPIT WALL AT RBL 10 IS CORRODED AND HAS BEEN REPAIRED IAW MESABA EO#S53185. REF: EAMS WORK ORDER 213743 TASK 2526.SDR MALA060259Panel · corrodedDURING 2 YEAR CHECK IN BNA, FOUND LOWER END OF COCKPIT WALL AT LBL 10 IS CORRODED AND HAS BEEN REPAIRED IAW MESABA EO#S53185. REF: EAMS WORK ORDER 213743 TASK 2523.SDR 04202006CEngine · faultyRT ENGINE NOT MAKING T/O POWER. R&R RT ENGINE IAW 71-00-01S. OPS CHECK GOOD.SDR SIMA200610901Fuse · blownNOTIFIED BY DISPATCH, OVERWING EMERGENCY EXIT SIGNS WON`T LIGHT UP. FOUND AND REPLACED TWO BLOWN POWER SUPPLY FUSES. RE-SOLDERED WIRES TO FUSE 22LN. NO FURTHER DEFECTS NOTED. AIRCRAFT RETURNED TO SERVICE. (M)SDR 04172006DLight · malfunctionedROW 7 EMERGENCY LIGHTS WILL NOT STAY ON DURING TESTING. PERFORMED OPERATIONAL CHECK OF EMERGENCY LIGHTING SYSTEM, NO DEFECTS NOTED.SDR 04172006CLight · inoperativeEMERGENCY FLOOR LIGHT 53LN IS INOP FOURTH LIGHT FROM FRONT RIGHT SIDE. REMOVED AND REPLACED EMERGENCY FLOOR LIGHT 53LN AND EMERGENCY CEILING LIGHT.SDR MALA060270Starter Gen · malfunctionedLT DC GEN LIGHT ILLUMINATED IN FLIGHT. AIR RETURNED TO MSP. REPLACED DC STARTER GEN.SDR MALA060269Wire Harness · damagedRIGHT HAND MAIN GEAR GREEN DOWN AND LOCK LIGHT FLICKERED ON AND OFF IN FLIGHT WITH THE GEAR UP AND LOCKED. AIR RETURNED TO DTW. REPLACED RT DOWN LOCK HARNESS ASSY.SDR 04172006AConnector · dirtyMAIN AILERON ROLL TRIM DOESN’T RETURN TO DOWN POSITION. CLEANED LT AILERON TRIM ACTUATOR CANNON PLUG.SDR 04102006AConnector · dirtyINTERMITTENT LAV SMOKE ILLUMINATED IN FLIGHT. CLEANED CONNECTOR AND DETECTOR, OPS CHECK GOOD.SDR MALA060240Skin · delaminatedDURING 2 YEAR CHECK IN BNA FOUND LT AILERON P/N 7257610-621, S/N 0260, IS DELAMINATED ON LOWER SURFACE, 38" FROM INBOARD END AND 2.5" FORWARD OF TRIM TAB. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO#S57115. REF: EAMS WORK ORDER 213710 TASK 5505.SDR 04052006ASmoke Detector · malfunctionedDURING ENGINE START WITH BATTERIES THE CARGO SMOKE LIGHT ILLUMINATED AND TURNED OFF AFTER 55% ENGINE RPM. R&R AFT CARGO SMOKE DETECTOR IAW 26-13-15 OPS CHECK GOOD.SDR MALA060235Seat Track · corrodedDURING 4K CHECK IN BNA, FOUND SEAT TRACK AT LBL 18.3, INBOARD FLANGE, IS CORRODED OUT OF LIMITS, BETWEEN FS 294 AND 365. THE TRACK HAS BEEN REMOVED AND REPLACED IAW MESABA EO S53060. REF: EAMS WORK ORDER 213694 TASK 1522.SDR MALA060236Seat Track · corrodedDURING 4K CHECK IN BNA, FOUND SEAT TRACK AT BLO, INBOARD FLANGE, IS CORRODED OUT OF LIMITS, BETWEEN FS294 AND 365. THE TRACK HAS BEEN REMOVED AND REPLACED IAW MESABA EOS53060. REF: EAMS WORK ORDER 213694 TASK 1523.SDR MALA060233Deice System · malfunctionedINFLIGHT R PROP CAUTION LIGHT ILLUMINATED W/SWITCH IN NORM IN ICING CONDITIONS. FOLLOWED QRH. STILL NOT WORKING. LIGHT COMES ON WITHIN 35 SECONDS. REPLACED RT PROP DEICER LEADS ON NR 1 AND NR 3 PROP BLADES PER TASK 3060-301, P/N 660714263.SDR MALA060234Skin · puncturedDURING 2 YEAR CHECK IN BNA, FOUND LT ELEVATOR UPPER SURFACE HAS PUNCTURE 39.5 INCHES FROM O/B END 3.5 INCHES FWD OF TRAILING EDGE. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO S51031. REF: EAMS WORK ORDER 213686 TASK 3507.SDR MALA060219Relay · failedON DEPARTURE CLIMB, THE CREW EXPERIECED FAILURE OF THE LEFT ADI (DIMMING). THIS OCCURRED WHEN THE HYDRAULIC PUMP WAS ACTIVATED. THE FLIGHT RETURNED TO DTW WITHOUT FURTHER INCIDENT. REMOVED AND REPLACED RELAY 9PC. ALL CHECKS GOOD.SDR MALA060215Sensor · malfunctionedTHE RT PROP RPM GAUGE IS ERRATIC WHEN SET TO 1270 RPM. IT MOVES BETWEEN 1200-1270 RPM. ALL OTHER INDICATIONS NORMAL. REMOVED AND REPLACED PROP SPEED SENSOR PN 488T42P01 IAW CT7 MM 74-00-00 PGS 426-427. OPS CHECK GOOD. LEAK CHECK GOOD.SDR MALA060214Intake Duct · odorSHORTLY AFTER TURNING ON RIGHT ENGINE ANTI-ICE SWITCH, A VERY STRONG BURNING ODOR APPEARED IN THE COCKPIT WITH NO ASSOCIATED SMOKE. SHORTLY THEREAFTER RIGHT INTAKE FAILED WITH ASSOCIATED ANNUNCIATOR. LEFT THE SWITCH OFF AND SMELL DISSIPATED. AIR RETURNED TOSDR MALA060218Engine · unknownAT APPROX 700-800 FT AGL, LEFT ENGINE MADE WHAT SOUNDED LIKE A COMPRESSOR STALL. ENGINE MADE A SERIES OF POPPING NOISES AND THEN SHUT DOWN. ALL QRH CHECKLISTS COMPLETED. NO FIRE INDICATION. REMOVED AND REPLACED ENGINE LT IAW JC 7100-301.SDR MALA060232Control Unit · malfunctionedUPON TAKEOFF FROM MSP, THE CREW RETRACTED THE LANDING GEAR AND HAD 3 GREEN AND THE GEAR INTRANSIT LIGHT ILLUMINATED. THE CAPTAIN STATED THAT THERE WAS NOTHING IN THE QRH FOR THIS PROBLEM. THE CREW EXTENDED THE LANDING GEAR AND THE AIRCRAFT RETURNED TO MSP. SDR MALA060210Engine · malfunctionedDURING CLIMB-OUT , NOTICED A SHIFT IN DDT. COMPLETED AN ENGINE TREND WHICH SHOWED A DDT OF 64 DEG. ORH'D DDT REMAINED AT 64 DEG. NG RANGE OF 80-84% COULD NOT BE AVOIDED. RETURNED TO MSP. REPLACED RT ENGINE, SN OFF GE-E758742. SN ON GE-E785682.SDR MALA060211Control Unit · malfunctionedGEAR SEEMS TO WORK PROPERLY, BUT GEAR TRANSIT LIGHT STAYS ON WITH LEVER UP AND/OR DOWN. RETURNED TO MSP. FOUND LANDING GEAR CONTROL UNIT LAMPS TEST BUTTON STICKY. REPLACED LANDING GEAR CONTROL UNIT PN D494-10-001, SN OFF 204/07-87, SN ON 095/07-85 IAW AMM 2SDR MALA060196Engine · malfunctionedDURING CLIMB-OUT, NOTICE A SHIFT IN DDT. COMPLETED AND ENGINE TREND WHICH SHOWED A DDT OF 64 DEG. QRH'D DDT REMAINED AT 64 DEG, NG RANGE OF 80-84% COULD NOT BE AVOIDED. REPLACED RT ENGINE SN OFF GE-E758742, SN ON GE-E785682.SDR MALA060197Battery Pack · no testFAILED CAP CHECK PER CMM WO 406706. REPLACED BATTERY PACK.SDR MALA060195Battery Pack · no testFAILED CAP CHECK PER DEILH CMM WO 406461. REPLACED BATTERY PACK.SDR MALA060199Seat Track · corrodedDURING 2 YEAR CHECK IN BNA, FOUND PREVIOUS REPAIR TO SEAT TRACK AT BL0 IS CORRODED OUT OF LIMITS BETWEEN FS 297 AND 303. THE REPAIR HAS BEEN REMOVED AND REPLACED IAW MESABA EO#S53342. REF: EAMS WORK ORDER 213664 TASK 1513.SDR MALA060200Frame · chafedDURING 2 YEAR CHECK IN BNA, FOUND INNER FLANGE OF FRAME AT FS 686.888 HAS BEEN CHAFED OUT OF LIMITS FROM CONTACT WITH THE INTERIOR CARGO PANEL. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO#S53356. REF: EAMS WORK ORDER 213664 TASK 2502.SDR MALA060198Seat Track · corrodedDURING 2 YEAR CHECK IN BNA, FOUND PREVIOUS REPAIR TO SEAT TRACK AT LBL 18.3 IS CORRODED OUT OF LIMITS BETWEEN FS297 AND 303. THE REPAIR HAS BEEN REMOVED AND REPLACED IAW MESABA EO#S53342. REF: EAMS WORK ORDER 213664 TASK 1512SDR MALA060194Battery Pack · no testFAILED CAP CHECK PER WO 406707. REPLACED BATTERY PACK.SDR MALA060193Battery Pack · no testFAILED CAP CHECK PER WO 406463. REPLACED BATTERY PACK.SDR 03282006AHmu · out of adjustRT PROP IS SLOW TO FEATHER. ADJUSTED RT CONDITION CONTROL RIGGING AT HMU GEARBOX AND PCU IAW 76-10-00SDR MALA060192Battery Pack · no testFAILED CAP CHECK. REPLACED BATTERY PACK.SDR MALA060191Battery Pack · no testFAILED CAP CHECK PER DIEL CMM WO 406576. REPLACED BATTERY PACK.SDR MALA060190Nozzle · chafedDURING N4K CHECK IN BNA, FOUND RT IPD IS CHAFED AND MESABA EO#S54133 HAS BEEN INSTALLED. REF: EAMS WORK ORDER 213667 TASK 4508.SDR MALA060188Frame · chafedDURING N4K CHECK IN BNA, FOUND NR 1 NACELLE, FORWARD FRAME AT NS 197 IS CHAFED OUT OF LIMITS ON THE INBOARD SIDE. THE DAMAGE HAS BEEN REPAIRED IAW MESABA EO#S54156. REF. EAMS WORK ORDER 213668 TASK 4503.SDR MALA060189Nozzle · chafedDURING N4K CHECK IN BNA, FOUND LT IPD IS CHAFED AND MESABA EO NR S54133 HAS BEEN INSTALLED. REF: EAMS WORK ORDER 213667 TASK 4509.SDR MALA060186Floor Support · corrodedDURING 2 YEAR CHECK IN BNA, FOUND FLOOR FLANGE AT RBL 33 IS CORRODED OUT OF LIMITS IN 3 AREAS, FS 323-335, FS 352 TO 360 AND FS 377 TO 389. DOUBLERS HAVE BEEN FABRICATED IAW SRM 51-20-20 AND 51-40-60, AND INSTALLED IAW SRM 51-40-21. REF: EAMS WORK ORDER 2136SDR MALA060185Seat Track · corrodedDURING 2 YEAR CHECK IN BNA, FOUND SEAT TRACK AT BL 0 IS CORRODED OUT OF LIMITS BETWEEN FS 296 AND 319. DAMAGED TRACK HAS BEEN REMOVED AND REPLACED IAW MESABA EOS53060. REF. EAMS WORK ORDER TASK 1526.SDR MALA060184Seat Track · corrodedDURING 2 YEAR CHECK IN BNA, FOUND SEAT TRACK AT LBL 18.3 IS CORRODED OUT OF LIMITS BETWEEEN FS 296 AND 319. DAMAGED TRACK HAS BEEN REMOVED AND REPLACED IAW MESABA EO#S53060. REF: EAMS WORK ORDER TASK 1525.SDR MALA060183Floorbeam · corrodedDURING 2 YEAR CHECK IN BNA, FOUND FLOOR FLANGE AT FS 258 IS CORRODED OUT OF LIMITS. THE FLANGE HAS BEEN REMOVED AND A NEW PART FABRICATED PER SAMPLE IAW SRM 51-20-20 AND INSTALLED IAW SRM 51-40-21. REF: EAMS WORK ORDER 213643 TASK 1513.SDR MALA060181Nozzle · chafedDURING 2 YEAR CHECK IN BNA, FOUND RT IPD IS CHAFED AND HAS BEEN REPAIRED IAW MESABA EO S54133. REF: EAMS WORK ORDER 213644 TASK 4506.
Back to Saab 340B