What was found
RT WING I/B LOAD FITTING HAS 3 FASTENER HOLES DAMAGED COMMON TO THE SIDE LOAD FITTING. REF S/B 757-54-0035 FIG 7, PANEL 3, STEPS 2 AND 3 IAW EA NR F-5450-108908, REAMED EACH HOLE TO REMOVE DAMAGE. ACCOMPLISHED BHEC OF THE REWORKED HOLES PER 757 NDT MANUAL D6-34N301, PART 6, SUB 51-00-16. FABRICATED 3 EACH REPAIR BUSHINGS AND INSTALLED THEM WET WITH BMS 5-95 PER SOPM 20-50-03. REAMED ALL 3 REPAIR BUSHINGS ON CENTER TO 0.325" TO 0.328". PERFORMED A DVI AFTER FINAL REAMING OF BUSHINGS. APPLIED ALODINE AND BMS 10-11, TYPE 1 PRIMER TO THE REPAIR AREA AND THE BUSHING ID'S.