As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RIGHT PATIO DOOR FWD END ATTACH CLIP IS GOUGED. REMOVED OLD STIFFENER (ATTACH CLIP) IAW DC/MD-10 SRM 51-35-01 VOL II. FORMED NEW STIFFENER PER FEDEX GMM 7-0-1001 SECTION 7 ITEM C & IAW DC/MD-10 SRM 51-10-00 VOL II. HEAT TREATED IAW TPS 1003 REV "A". HRB 62/63 HT 102608-1. LOCATED; DRILLED & DEBURRED PER FEDEX GMM 7-0-1001 SECTION 7 ITEM C & IAW DC/MD-10 SRM 51-31-01 VOL II. ALODINED & PRIMED IAW DC/MD-10 SRM 51-21-01 VOL II. INSTALLED STIFFENER IAW DC/MD-10 SRM 51-35-01 VOL II.