DURING PRELANDING PROCEDURES LANDING GEAR LIGHTS FAILED TO ILLUMINATE UPON GEAR EXTENSION. LANDING GEAR CIRCUIT BREAKER WAS RECYCLED SEVERAL TIMES AND LANDING GEAR POSITION WAS RECYCLED SEVERAL TIMES. AFTER THE CIRCUIT BREAKERS WERE RECYCLED LANDING GEAR LIGHTS WERE ILLUMINATED ON GEAR EXTENSION AND GEAR RETRACTION POSITIONS. MAINTENANCE REMOVED UPLIMIT CABLE ASSY AND INSTALLED SERVICEABLE CABLE ASSEMBLY. PERFORMED LANDING GEAR RETRACTION TEST TWENTY TIMES WITHOUT INCIDENT. (M)