As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
THE LANDING GEAR DOWN POST "F" TERMINAL, FIELD COIL SHORTED TO GROUND INSIDE THE LT MLG MOTOR ASSY. REPAIR FACILITY WAS CONSULTED AS TO THE PROBABLE CAUSE OF THE ERMINAL INSULATOR FAILURE. THEY INDICATED EITHER OVER-TIGHTENING OF THE TERMINAL HARDWARE OR DAMAGE TO THE TERMINAL INSULATOR DURING SHIPMENT OR STORAGE. TERMINAL GUARDS ARE NOW EMPLOYED.