What was found
DURING WALK AROUND CHECK(WAC) AT JED STATION, NOSE LANDING GEAR FORK FOUND TWISTED ON RT, REFER TO TL SEQ 505212. REMOVED AND INSTALLED NOSE GEAR STRUT ASSEMBLY (REPAIRED) IAW AMM 32-20-00-04. PERFORMED LANDING GEAR OPERATIONAL CHECK IAW AMM 32-30-00-2, FOUND SATISFACTORY, REFER TO TL SEQ 505219. MALFUNCTION OR DEFECT REPORT (MDR) IS NOW CONSIDERED CLOSED.