What was found
APU WILL NOT START, START SEQUENCE NORMAL TO 25 PERCENT RPM, THEN RPM HANGS AND STRONG ODOR OF JET FUEL PRESENT. RAMP AGENTS REPORT SMOKE FROM APU EXHAUST. REPLACED APU IGNITION UNIT IAW AMM 49-41-01. OPS CK OF APU GOOD AT THIS TIME.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU WILL NOT START, START SEQUENCE NORMAL TO 25 PERCENT RPM, THEN RPM HANGS AND STRONG ODOR OF JET FUEL PRESENT. RAMP AGENTS REPORT SMOKE FROM APU EXHAUST. REPLACED APU IGNITION UNIT IAW AMM 49-41-01. OPS CK OF APU GOOD AT THIS TIME.