What was found
L/H HORIZONTAL STABILIZER JACKSCREW FITTING HAS GOUGE ON I/B FASTENER BRACKET. DIMENSIONS ARE: (P1) 2.150L X 1.650W X .010D. EVALUATED GOUGE AND FOUND NOT WITHIN ALLOWABLE LIMITS IAW CRJ200 SRM 55-11-27 REV. 38. ****************AIRCRAFT REMOVED FROM SERVICE*********************** BLENDED DAMAGED AREA ON BRACKET TO A SMOOTH CONTOUR. SHOT-PEENED REPAIR AREA. VERIFIED NO LOOSE/PULLED FASTENERS AND NO DAMAGE TO UNDERLYING STRUCTURE COMMON TO REPAIR AREA. HFEC PERFORMED WITH NO INDICATIONS. RESTORED PROTECTIVE FINISH. RE-EVALUATED AREA AND FOUND WITHIN LIMITS IAW MHIRJ REO 601R-55-11-709 REV (--) DATED 2022-01-15. ALL WORK PERFORMED IAW MHIRJ REO 601R-55-11-709 REV (--) DATED 2022-01-15. WORK COMPLETED AT AERSALE CRS4AER685B ON W/O #003526 CARD #20149. N438AW TT:39,745:56 TC: 39,335