What was found
R/H H STAB FITTING #2 HAS 2 EACH GOUGES AT ES60.525 (RBL55.8865). DIMENSIONS ARE: (P1) 1.00L X 0.200W X .006D (P2) 1.100L X 0.200W X .015D. BOTH GOUGES ARE NOT WITHIN ALLOWABLE LIMITS IAW CRJ200 SRM 55-11-27 REV. 38. ****************AIRCRAFT REMOVED FROM SERVICE*********************** BLENDED DAMAGED AREAS ON FITTING TO A SMOOTH CONTOUR. SHOT-PEENED REPAIR AREA. VERIFIED NO LOOSE/PULLED FASTENERS AND NO DAMAGE TO UNDERLYING STRUCTURE COMMON TO REPAIR AREA. HFEC PERFORMED WITH NO INDICATIONS. RESTORED PROTECTIVE FINISH. RE-EVALUATED AREA AND FOUND WITHIN LIMITS IAW MHIRJ REO 601R-55-21-711 REV A DATED 2022-01-17. ALL WORK PERFORMED IAW MHIRJ REO 601R-55-21-711 REV A DATED 2022-01-17. WORK COMPLETED AT AERSALE CRS4AER685B ON W/O #003526 CARD #20331. N438AW TT:39,745:56 TC: 39,335