What was found
VENT EXTRACT FAULT FOLLOWED BY ACRID FUMES THROUGHOUT AIRCRAFT, ESPECIALLY BAD IN COCKPIT. AIRCRAFT WAS GROUNDED. REPLACED AVIONICS EXTRACT FAN (18HQ) IAW AMM 21-26-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.