Service difficulty report · Servo Valve · Airbus A300*

Difficulty date
March 8, 2022
Submitted
March 10, 2022
Operation
Air carrier
Aircraft
N980UY
Make and model
Airbus A300*
Aircraft serial
5795
Aircraft time
26,883 hours, 10,412 cycles
Part
Servo Valve
Condition
Fault Message
Location
Zone 600 - Rh Wi
Stage of operation
NR
How discovered
V
Nature of condition
F, J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GROUNDED: FLIGHT CONTROL AILERON GREEN SYSTEM SERVO FAULT 2 ALONG WITH UN-COMMANDED AIRCRAFT ROLL. FLIGHT CREW REPORTED THE RIGHT WING DIPPED WHEN THE AILERON SERVO FAULT APPEARED. **SUPPLEMENTAL REPORT FOR AALA202203097350: REPLACED RIGHT WING AILERON SERVO VALVE FOR GREEN SYSTEM PER AMM 27-14-51. MAINTENANCE ALSO REPLACED THE ELEVATOR AILERON COMPUTER #1 (ELAC) PER AMM 27-93-34. (AALA202203108344) A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED ** (CLOSED)