As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ELEC IDG 1 OIL OVERHEAT DURING FLIGHT / IN ACCORDANCE WITH AMM TASK 24-21-51-000-040/400-040 IDG 4000XU ON ENG 1 WAS REPLACED, AS PER TSM 24-00-00-810-816-A; OIL SERVICE WA ACCOMPLISHED REF AMM 12-13-24-612-041 PENDING TEST / IN ACCORDANCE WITH AMM 24-21--00-710-041-A OPERATIONAL TEST OF THE IDG DISCONNECT AND RECONNECTE FUNCTION WAS PERFORMED SATISFACTORY