What was found
AUTOLAND UNSUCCESSFUL. ACFT DOVE FOR RUNWAY DURING LAST 10 FEET CAUSING BOUNCING OF ACFT 3 FEET INTO THE AIR. ACFT GROUNDED. PERFORMED DFCS FAULT REVIEW (BITE GRP 20) IAW FIM 22-11, TASK 801, NO FAULTS. PERFORMED RECORDED FAULT REVIEW OF HGS IAW SMM REF 34-36-00, FOUND ILS ANOMALY APPROACH WORN LONG POS EXCEED. PRECAUTIONARY PERFORMED DFCS. LRU REPLACEMENT TEST FOR MMR/ILS IAW FIM 22-11, TASK 802 AND HGS SENSOR TEST FOR MMR/ILS IAW SMM REF 34-36-00. BOTH TESTS PASS.