What was found
WINDOW HEAT "R" SIDE OVERHEATED TWICE. WOULD NOT RESET. ACFT GROUNDED. BITE TEST SHOWS SENSOR FAULT,IMMEDIATE, SWAPPED TO A/T SENSOR, TEST CABLE, DELAYED OVERHEAT W/SENSOR FAULT. HEATER RESISTANCE, D10572, PINS 3 & 4 = 59 OHMS, H15. CONFIRMED RT SLIDER WINDOW TAPS ARE CORRECT FOR H15 WINDOW REF WDM 30-41-11. REMOVED R2 SLIDING WINDOW IAW AMM 56-12-11-000-801. INSTALLED SERVICEABLE WINDOW IAW AMM 56-12-11-400-801. WINDOW HEAT OPS TEST IAW AMM 30-41-00-710-801, GOOD.