What was found
WINDOW LIGHTED NUMERALS CONSTANTLY PULSING ON MCP. ACFT GROUNDED. CONFIRMED FAULT. R & R DFCS MCP REF AMM 22-11-34, OPS CHECK NORMAL. ACCOMPLISHED DFCS LRU INTERFACE TEST MCP, GP 32, REF AMM 22-11-34, DFCS LAND VERIFY TEST, GP 49, REF AMM 22-11-00 AND HGS SENSOR TEST REF AMM 34-36-00, OPS CHECK NORMAL.