What was found
APU FAULT LIGHT CAME ON AT ATTEMPTED START. ACFT GROUNDED. REPLACED IGNITER PLUG AND APU IGNITION UNIT IAW AMM 49-41-51 AND 49-41-31. OPS TEST GOOD, BITE CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU FAULT LIGHT CAME ON AT ATTEMPTED START. ACFT GROUNDED. REPLACED IGNITER PLUG AND APU IGNITION UNIT IAW AMM 49-41-51 AND 49-41-31. OPS TEST GOOD, BITE CHECKED GOOD.