What was found
PILOT SELECTED START ON APU SWITCH, AND RELEASED TO RUN. AFTER APPROXIMATELY 2-3 MINUTES, PILOT OBSERVED APU EGT GUAGE READING BETWEEN 200-300 DEGREES, THE LOW OIL PRESSURE LIGHT ILLUMINATED, AND THE APU GEN OFF BUS LIGHT WAS NOT ILLUMINATED. PILOT SELECTED OFF ON APU SWITCH. GROUNDED - YES. ACCOMPLISHED FIM 49-15 TASK 805 AND FIM 49-60 TASK 801 NO FAULTS SHOWN IN CURRENT, MAINT, OR FAULT HISTORY. APU STARTED NORMALLY.