What was found
REF LOG 60923028 DURING UPGRADE TEST, DFCS FAILS 60.31 CH-B MSG 22-11146 & 22-11340. GROUNDED - YES. (RESOLVED ON W/O: 1975487 TASKCARD: N/R-00002 ) PERFORMED DFCS TEST 60.31 NO FAULTS ON CHANNEL A & CHANNEL B, CLEANED & RESITTED AILERON POSITION SENSOR CONNECTORS, AILERON POSITION SENSOR TEST GOOD FIM 22-12 TASK 813, FIM 22-16 TASK 829, WDM 22-11-31, AMM 22-11-2*9-710-801, ALSO PERFORMED LLM LAND VERIFIED TEST GOOD AMM 22-11-01/201, NO HISTORY LAST 60 DAYS, CLEARS MEL 22-1F & MEL 22-99B, PLACARD REMOVED, SEAMC NOTIFIED.