As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EQUIPMENT COOLING SUPPLY OFF AMBER ILLUMINATED IN FLIGHT. QRH EXECUTED. EQUIPMENT COOLING SWITCHED TO ALT, AMBER LIGHT EXTINGUISHED. ELECTRICAL ODOR SMELLED WHILE LIGHT WAS ILLUMINATED. GROUNDED - YES. ON M1322 (NORMAL SPLY FAN) ON D3470 PIN 1,2 AND 3, 115V AC IS PRESENT. PIN 5 AND 6 HAS GOOD GROUND REF WDM 21-27-31. REMOVED AND REPLACED EQUIPMENT COOLING SUPPLY FAN REF AMM 21-27-02-400-801. OPS CHECK GOOD, NO FURTHER DEFECT.