What was found
DURING TRANSIT CHECK, IT WAS DETECTED A FUEL LEAK IN THE RIGHT ENGINE. THE PLATFORM WAS CLEANED AND MAINTENANCE PERFORMED REVISION, DETECTING FUEL LEAK IN THE TRANSIENT BLEED VALVE WITH 4 DROPS PER MINUTE WITHIN OPERATION LIMITS IAW AMM 71-71-00 PAGE 6, DISPATCHING THE AIRCRAFT IN SUCH CONDITION. AT MEX, AS A PRECAUTIONARY ACTION, THE TRANSIENT BLEED VALVE WAS REPLACED IAW MM 75-23-01 AND PERFORMED OPERATIONAL TEST IAW MM 71-00-00, ALL CORRECT.