Service difficulty report · Relay · Beech 1900C

Difficulty date
December 28, 2012
Submitted
September 14, 2015
Operation
General aviation
Make and model
Beech 1900C
Aircraft time
27,045 hours
Engine
Pwa PT6A65B
Propeller
Hartzl HCB4MP3
Part
Relay
Part number
MS24171D1
Condition
Failed
Location
Power Pack
Stage of operation
DE
How discovered
9
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) GEAR WAS UNSAFE GOING INTO DESCENT, DIDN`T GET 3 GREEN SO DID AN OVERSHOOT, VFR AND CYCLED THE GEAR IAW CHECKLIST. THE NEXT STEP WAS TO MANUALLY PUMP THE GEAR SO THE CREW OPTED TO GO DIRECT TO THE MAINTENANCE BASE. MAINTENANCE PERSONNEL DISCOVERED THAT THE MAIN HYD POWER PACK CONTROL RELAY CONTACTS HAD WELDED IN THE CLOSED POSITION WHICH MADE THE HYD POWER PACK RUN CONTINUOUSLY. THIS CAUSED THE POWER PACK MOTOR TO FAIL. THIS POWER PACK RELAY IS NOT COVERED UNDER THE ACFT INSPECTION PROGRAM AS AN ITEM TO INSPECT.