Service difficulty report · Receptacle · Emb ERJ190100IGW

Difficulty date
March 8, 2015
Submitted
August 5, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
23,230 hours
Engine
Ge CF3410E5A1
Part
Receptacle
Part number
17013624505
Condition
Damaged
Location
External Power
Stage of operation
TX
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ELECTRICAL ARCING AND BLACK BURN MARKS PRODUCED WHEN CONNECTING A MOBILE GROUND POWER UNIT TO ACFT. PASSENGERS WERE DEPLANED. CRASH FIRE RESCUE RESPONDED. NO INJURIES REPORTED. REMOVED AC POWER RECEPTACLE IAW AMM 24-42-03-000-801-A. FOUND COMPOSITE PANEL DAMAGE ON EDGE OF CUTOUT. EDGE PANEL DAMAGE REPAIRED IAW SRM 51-71-01 RE FOR FULL REPLACEMENT OF THE EXT. PWR RECEPTICAL BOX NEXT BSA 01 CHECK IAW PP ERJ190-24-56166. INSTALLED NEW AC POWER RECEPTICAL IAW AMM 24-42-03-400-801-A FUNCTION CHECK CARRIED OUT NO FAULTS. NO ACFT DEFECTS RELATED TO OVERVOLTAGE, OVERCURRENT, AND INTERLOCK. SYSTEM SERVICEABLE.

More about the Emb ERJ 190-100 IGW