What was found
DURING CLIMB THE NR 2 OVERHEAT AND ENG 2 CUT OFF LIGHT COME ON AND OFF 4 TIMES. THEY WERE ON FOR 1 SEC AND THEN WENT OFF. RETURNED TO EWR. T/S PER FIM 26-10-00-810-805. FOUND WIRES DAMAGED ON STUDS FOR M1757. REMOVED AND REPLACED MW0316 PER WDM 26-11-11 PAGE 1 AND REPLACED M279 DUE TO DAMAGE ON ONE OF RETENTION BAR. OPS CHECK GOOD. RUN ENGINE NR 2 FOR SAFETY FACTOR. OK FOR SERVICE. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1442321, S/N OFF 01395 PANEL, CONTROL OFF 29-2615-9-0001 1395, ON 29-2615-9-0001 1359.