What was found
IAW LOG1 REPLACED FIRST OFFICERS PITOT STATIC CURRENT SENSING RELAY K310 IAW WAM 30-31-21, NO HELP. SLAVED NEW PITOT PROBE ALL TESTED GOOD, NEED NEW FIRST OFFICERS PROBE AMM. OLD PROBE CONNECTOR SAFETY WIRE BROKEN, REPLACED PITOT, FIRST OFFICERS SIDE IAW AMM. PN 08561LU6 SN OFF 218422 SN ON 1666701.