What was found
FOUND DAMAGE TO BE 2 INCHES LONG BY 1.5 INCHES WIDE BY .094 INCHES DEEP AT STATION 400 BETWEEN STRINGER 31L & 32L. PLACED DENT ON DIP IAW SRM 53-00-01 ALLOWABLE 1. MAKE A DETAIL INSPECTION EVERY 300 FLIGHT CYCLES. HEFC INSPECTION EVERY 3000 FIGHT CYCLES OR STRUCTURAL C CHECK. PERMANENT REPAIR THE NEXT SCHEDULE HEAVY MX OR STRUCTURAL 4C CHECK. INSPECTION DENT NO OTHER DAMAGE NOTED DIP REMAINS FUSELAGE STATION 400 BETWEEN STRINGER 31L & 32L SKIN REPAIRED IAW ECRA 5330-04981 REV PART 1. ACCOMPLISHED MX WORK SHEET 44.0008 ITEM 1 TO ITEM 22.