What was found
CREW REPORT OF ODOR IN CABIN PRIOR TO THE LT RECIRCULATION FAN EICAS MESSAGE, ACCOMPLISHED AN IN CABIN SMOKE - FUME CONDITIONAL INSPECTION IAW AMM 05- 51-56-201 AND ECRA 0500-01055. FOUND THE LT RECIRCULATION FAN STUCK, NO OTHER CONDITION THAT CAN CAUSE SMOKE OR FUMES OBSERVED. REMOVED & REPLACED THE RECIRCULATION FAN IAW MM 21-25-01. OPS NORMAL.