What was found
LEFT WINDOW OVHT LIGHT ON IN CLIMB FL315 PERFORMED CONTINUITY CHECK PER FIM 30-41-830 STEPS D3CONTINUITY CHECKS GOOD. FIM RECOMMENDS TO REPLACE P5-9 OVERHEAD PANEL, CONF IRMED FAILURE PER BITE CHECK ON WHC#2. R & R MODULE , WINDOW / PITOT HEAT AS REQUIRED , REF AMM 30-00-02-401, OPS CHECKED NORMAL. WING BODY OVHT LIGHT ON AT FL295 IN CLIMB PERFOMED SYSTEM TEST AND FAULT AFT CARGO APU SHORT FAULT DETECTED. ELEMENT LOOP 275 WAS PREVIOUSLY REPLACED ON 2-21-2024 BUT ERROR WAS NOT RESET FROM OVERHEAT DETECTOR CONTROLLER. RESET OVERHEAT CONTROLLER TO CLEAR FAULT AND RETESTED SAME WITH NO FURTHER DEFECTS/FAULTS NOTED. A/OK FOR SERVICE.