As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
OVEN 707 EMITTED BLACK SMOKE CB PULLED AS RECAUTION OVEN 707 IN REAR GALLEY, SMOKE EVENT. CONDITIONAL INSPECTION CARRIED OUT I.A.W AMM 05-51-58. BURNT FOOD IN OVEN FOUND. FORM 46.6020 SMOKE AND ODOR QUESTIONAIRE COMPLETED IAW 04-20-16 OF THE GMM. OVEN PLACED ON MEL 2520V. CB. PULLED AND COLLARED FOR OVEN 707 AND PLACARDED. REMOVED AND REPLACED THE OVEN IAW AMM 25-32-02/401. PERFORMED OVEN SELF TEST IAW AMM 25-32-02/401, OPS CHECKED GOOD.