What was found
BIRD STRIKE ON THE RT LANDING GEAR SEMI STRUT CONTROL UNIT. DAMAGED JUNCTIONS BOX BIRD STRIKE. INSPECTION PERFORMED IAW AMM DMC-B787-A-05-51-18-00A-280A-A, REV 209. FOUND THE JUNCTION BOX ON THE RT MLG SEMI LEVER GEAR DAMAGED.NO OTHER DAMAGE FOUND AFTER CLEAN UP. JUNCTION BOX DAMAGE LIMITED TO METALLIC HOUSING IAW ECRA 3232-01147 REV A.PART 1, INTERIM REPAIR PERFORMED. CLEANING AND INSPECTION C/O NO OTHER DAMAGE FOUND. NO FAULT INDICATIONS SHOWING. NO ELECTRICAL WIRE DAMAGE. COVER & JUNCTION BOX REFORMED AS CLOSE TO ORIGINAL. A MINIMUM OF TWO FASTENERS I NSTALLED AND SECURED. 2 LAYERS OF HST APPLIED OVER THE COVER OF THE JUNCTION BOX .