Service difficulty report · Electrical Sys · Cessna 208B

Difficulty date
May 13, 2025
Submitted
May 14, 2025
Operation
Air carrier
Aircraft
N705FX
Make and model
Cessna 208B
Aircraft serial
0425
Aircraft time
11,264 hours, 14,671 cycles
Part
Electrical Sys
Condition
Warning Light
Location
Zone 200
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT. 8676 ENROUTE ANC-HOM AIR TURNBACK DURING CLIMBOUT, THE PILOT RECEIVED A STANDBY POWER ELECTRIC INOP ALERT. THE AIRCRAFT WAS RETURNED TO ANC. NO EMERGENCY WAS DECLARED. LANDED WITHOUT FURTHER INCIDENT. CORRECTIVE ACTION: THE ISSUE WAS DEFERRED AND THE AIRCRAFT WAS RETURNED TO SERVICE. THE DEFERRAL WAS CLEARED FOLLOWING AN OPS CHECK OF THE STANDBY POWER. NO DEFECTS NOTED.