What was found
RT HORIZ STAB L/E INNER RIB CRACKED .5 INCH AT XF 116.000. STOP DRILLED CRACK PER SRM 55-2-0. FABRICATED DOUBLER PER SRM 55-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED DOUBLER PER SRM 55-2-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT HORIZ STAB L/E INNER RIB CRACKED .5 INCH AT XF 116.000. STOP DRILLED CRACK PER SRM 55-2-0. FABRICATED DOUBLER PER SRM 55-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8B. INSTALLED DOUBLER PER SRM 55-2-0.